You are on page 1of 7

CO2 | O2 | TPO

Meter series

Lab and at-line CO2/O2 meters and


TPO meter for the beverage industry
Throughout the entire production process:
Measurement of TPO, dissolved CO2, and O2 in beverages The choice is yours

In the production of alcoholic and non-alcoholic beverages, it is essential to check and control Whether directly at the production line, in the laboratory, or as part of a larger beverage analyzing
the CO2 and O2 content of the product both during the production process and after bottling. system, Anton Paar provides the best instrument for your measurement application. The portfolio
In addition, measuring the total package oxygen (TPO) content is of great importance as well. includes instruments for selectively measuring total package oxygen, dissolved oxygen, and
dissolved carbon dioxide without being influenced by other gases.

CO2 CO2 | O2
Air | N2 | O2 Index Air | N2 | Index O2

The CO2 content strongly influences the taste of Precise measurement of the car­­­­bon ­­dioxide
beverages and is a considerable cost factor in ensures consistent taste and cost-efficient
beverage production. dosing.
At-line
measurement CarboQC At-line CboxQC At-line OxyQC | OxyQC Wide Range

A high level of O2 in bever­ages The continuous monitoring of the oxygen


has a negative impact on the taste and content ensures product safety and
shelf life of the beverage. permanent beverage quality.
Laboratory
measurement CarboQC CboxQC OxyQC | OxyQC Wide Range

Have it all: CO2 and O2 combined


System modules
CboxQC combines the fast measurement of CO2 and O2 integrated in PBA M CarboQC ME
in one measuring cycle. measuring systems CarboQC ME with Option O2 (Plus)

Combined TPO and CO2 measurement


TPO 5000 can be teamed up with Anton Paar's
carbonation meter to measure both TPO and dissolved
CO2 in one measuring cycle. CarboQC selectively
determines the true amount of carbon dioxide in beverages
and can be used as a stand-alone instrument as well.

Laboratory
and process
environment TPO 5000 TPO 5000 | CarboQC

TPO TPO | CO2


Your future with TPO 5000:
The rapid way to measure total package oxygen
Effortless and fast TPO measurement out of any standard bottle or can is without a doubt the Speed matters
major requirement right after filling. Anton Paar’s solution for TPO measurement provides many
time-saving and beneficial features in order to guarantee reliable QC. Sample preparation is not Speeding up measuring time is important – especially
required in the stand-alone solution. when it comes to TPO measurement right after filling. No
matter which beverage container type, the positioning
of the cans, glass bottles, and PET bottles is simplified
Avoid downtimes by always knowing by using an automatic centering adapter. The instrument
the status of the instrument supports you at every step in the process to prevent
handling issues before they even occur. The measuring
The built-in LEDs give you an immediate overview of time of less than four minutes makes TPO 5000 the
the instrument’s status throughout the whole production fastest TPO measuring device on the market.
process, even in noisy environments. The status of the
instrument can be identified immediately, even from a
distance.
State-of-the-art oxygen measurement with
minimum maintenance
Traceability is crucial Optochemical oxygen measurement is the worry-free
method for selectively measuring headspace oxygen
Checking and adjusting the instrument is a frequently and dissolved oxygen. No influence from other gases
performed task. With the implemented standard operation is guaranteed and there is no need to replace various
procedures, this requires no extra effort from the operator. consumables on a regular basis.
All data is saved on the instrument, which greatly
supports process stability.

No manual cleaning necessary

Endurance is the key to performance Anton Paar’s TPO 5000 is equipped with a self-cleaning
functionality for automatic cleaning after each
The solid, stainless steel housing provides long-lasting measurement without active user interaction. This unique
resistance to process environments. TPO 5000 meets the feature ensures that the instrument is always ready for the
highest safety standards on the market and has a splash- next measurement at any time.
proof design to ensure reliable and continuous operation,
even under harsh conditions.

TPO 5000
How about CO2? There you go.
Oxygen in the gas phase 0 hPa to 45 hPa O2 partial pressure
Dissolved oxygen 0 ppm to 2 ppm Anton Paar is well-known for modular solutions. That’s
Measuring
range
Temperature 0 °C to 40 °C why CarboQC, the CO2 meter for fast determination of
Pressure Max. 6.2 bar absolute
carbon dioxide, can be easily connected to TPO 5000.
Repeatability TPO ±5 ppb or ±5 % whichever is the greater
CarboQC selectively determines the true amount of
Environmental Ambient temperature 0 °C to 40 °C
conditions
carbon dioxide in beverages and can be used as a
Relative humidity (non-condensing) 10 % rH to 90 % rH
Package diameter from 35 mm to 90 mm
stand-alone instrument or in combination with TPO 5000
Package
Package height from 30 mm to 370 mm for combined TPO and CO2 measurements.
dimensions
Package volume >150 mL
Gas consumption / measurement Vn = 8 L
N2 or CO2 class 5
Required oxygen-free gases
(if TPO 5000 is used without CO2 measurement)
Additional gases Compressed air1
Cleaning Tap water or process water line
Communication interfaces 3x USB, Ethernet, CAN (for Anton Paar devices only), RS232
Display 7" LCD panel with projective capacitive touchscreen
Data storage Up to 5000 measurement data sets
Dimensions (L x W x H) 515 mm x 590 mm x 1120 mm (20.3 in x 23.3 in x 44.1 in)
Weight 70 kg (154 lbs)
1 Oxygen-free gas can be used if no compressed air connection is available.
At-line instruments from the measurement experts
At-line measurements – whether from filling lines, tankers, BBTs, kegs, or casks – provide the Staying within your beverage targets
assurance that your production process is under control. Besides this, at-line instruments are used
to monitor process instruments. The threshold value functionality enables you to set
CO2 and O2 target margins. Whenever your production
process shows slight target deviations, the instrument
reports immediately and you are on the safe side. This
is a time- and money-saver – your operators can take
Fully protected for harsh environments action within seconds.

Anton Paar’s at-line series of instruments is built to


operate under rough conditions. The robust and leakproof
housings keep humidity out of the electronics and stop Fast measurement saves you time
any spills from entering the instrument. and money
By measuring CO2 and O2 in only 90 seconds,
Anton Paar’s CboxQC At-line saves you valuable
Easy to use, easy to read working time and money.

The color display makes sure you see your measuring


results clearly, even in dark surroundings. Due to the
intuitive user interface, standard operations can be Teams up with process instrumentation
performed easily in nine different languages. The eight
large keys enable operation of the instrument even when The at-line instruments are the ideal complement
wearing protective gloves. to Anton Paar’s process instrumentation, such as
the Carbo 510 online CO2 analyzer and Cobrix 5
inline beverage analysis system for °Brix, Diet,
and CO2 monitoring.
Continuous control of CO2 and O2

Using the CO2 and O2 Data Logger function you define


the interval for automatic continuous measurements
from the sample point. With a memory capacity of 500
measurement data sets, Anton Paar's at-line instruments
are prepared for a long working day. OxyQC
CarboQC At-line CboxQC At-line OxyQC Wide Range

CO2 0 g/L to 12 g/L (0 vol. to 6 vol.) at 30 °C (86 °F)


0 ppm to 4 ppm
Get started fast with RFID Measuring range
O2 0 ppm to 4 ppm
0.015 ppm to 45 ppm
Temperature -3 °C to 40 °C (27 °F to 104 °F), acc. ±0.2 °C
Equipped with an RFID interface option, the instruments Pressure 0 bar to 10 bar absolute (0 psi to 145 psi), acc. 0.01 bar
enable you to quickly and conveniently start the CO2 0.04 g/L (0.02 vol.)
measurement by just reading a programmed RFID tag. Repeatability s.d. ±2 ppb (<200 ppb)
O2 ±2 ppb (<200 ppb)
Whether using RFID or manual settings, the instruments ±20 ppb (<5 ppm)
ensure full traceability. CO2 0.01 g/L
Resolution 0.1 ppb (<100 ppb)
O2 0.1 ppb (<100 ppb)
1 ppb
CO2 g/L, vol., mg/L, kg/cm², MPa, %w/w
Measuring units
O2 ppm, ppb, mg/L, μg/L, % Air-sat., % O2-sat.
Measuring time 55 seconds 90 seconds 50 seconds
Data memory 500 measurement data sets
Built-in support CO2 | O2 Data Logger, threshold value functionality, system check
Portable use Up to 10 hours continuous use
Interfaces 1x USB, 1x RS-232; optional: RFID, Bluetooth
Accessories High-performance battery, carrying strap, RFID tags, printer
Protection class IP67
Weight 2.1 kg (4.6 lbs) 2.7 kg (6 lbs) 1.7 kg (3.7 lbs)
Your longstanding partner for laboratory
measurements
Using Anton Paar’s laboratory solutions for dissolved gas Easy checks – reliable results
measurement allows you to perform reliable QC on finished
packages and run measurements for product development Anton Paar's CO2 and O2 meters are supplied
with the highest accuracy. factory-adjusted and can be used right from the start.
Numerous wizard features guide you through periodically
recommended system checks and help in your
everyday work.
Small sample amount? No problem!

The very low required sample volume of around 100 mL


allows reliable CO2 and O2 results, even out of very small Correct filling for correct results
packages.
Correct results strongly depend on the right filling
under pressure: The integrated FillingCheck™ feature
automatically detects filling errors.
High accuracy, more benefit

The patented selective CO2 measuring method is not


influenced by other dissolved gases such as air or Works through power outages
nitrogen. Together with the high-resolution optochemical
oxygen sensor the results achieve the highest accuracy. Voltage fluctuations or power outages are no threat for
the CO2 and O2 meters. They automatically switch to
battery-operated mode and you can easily continue your
measurements as planned without losing any data, time,
or money.
Low-carbonated beverages? No problem!

With a measuring range from 0 g/L to 12 g/L,


Anton Paar's CO2 meters not only measure highly
carbonated beverages, but also samples at low CO2
levels with outstanding accuracy.

OxyQC
CarboQC CboxQC OxyQC Wide Range

CO2 0 g/L to 12 g/L (0 vol. to 6 vol.) at 30 °C (86 °F)


0 ppm to 4 ppm
O2 0 ppm to 4 ppm
Measuring range 0.015 ppm to 45 ppm
Temperature -3 °C to 40 °C (27 °F to 104 °F), acc. ± 0.2 °C
Pressure 0 bar to 10 bar absolute (0 psi to 145 psi), acc. 0.01 bar
CO2 0.01 g/L (0.005 vol.)
Repeatability s.d. ±2 ppb (<200 ppb)
O2 ±2 ppb (<200 ppb)
±20 ppb (<5 ppm)
CO2 0.001 g/L
Resolution 0.1 ppb (<100 ppb)
O2 0.1 ppb (<100 ppb)
1 ppb
CO2 g/L, vol., mg/L, kg/cm², MPa, %w/w
Measuring units
O2 ppm, ppb, mg/L, μg/L, % Air-sat., % O2-sat.
Measuring time 55 seconds 90 seconds 50 seconds
Data memory 500 measurement data sets
Built-in support FillingCheck™, threshold value functionality, system check
Interfaces 1x USB, 1x RS-232 (CAN-open*); optional: RFID, Bluetooth
Accessories PFD, SFD, carrying strap, RFID tags, printer, rubber protection
Protection class IP67
Weight 2.0 kg (4.4 lbs) 2.6 kg (5.7 lbs) 1.7 kg (3.7 lbs)
* CarboQC and CboxQC only
The perfect complement Built to work in a team
Using Anton Paar's CO2 and O2 instruments in Which beverage parameters do you need to
combination with a piercing and filling device determine? Combine a CarboQC ME module
means easy handling. Just press 'Start' and the with a wide range of Anton Paar instruments
sample is transferred to the measuring chamber to get the beverage analysis you need in
without any loss of CO2 and O2. Reliable results one measuring cycle, with minimum sample
can therefore be guaranteed. preparation required. Beyond this, TPO 5000
can be combined with CarboQC as well.
Selective TPO and CO2 measurement is
SFD Sparkling Wine Filling Device performed out of the same beverage container.

Transfers samples from wine and sparkling wine bottles


closed with corks: Using SFD, the operator pierces the
cork manually and inserts a sample tube. The sample is
transferred under pressure. The SFD filling device can be
used with most plastic and traditional corks.

-- Full operator protection

-- For all sizes, from small bottles to magnum bottles

-- Sample transfer directly from the bottle

PFD Piercing and Filling Device

Fills samples reliably and safely directly out of closed


PET bottles, glass bottles, or cans into the measuring
chamber. No sample preparation, such as degassing or
filtering, is needed. Fit for the future

PFD pierces the bottle closure or the base of the can Whether you require an Alcolyzer system, the Option O2,
automatically and transfers sample from the package pH or other modules at a later date, Anton Paar's
using compressed gas. modular concept allows you to create a measuring
system that exactly suits your requirements.
-- Gas spring for safety shield ensures operator safety

-- Easy cleaning due to removable safety shield

-- Robustness guaranteed by clever design and


high-quality materials

-- Additional splinter shield for protection when the SFD


full amount of sample is needed out of glass and piercing and filling device for PFD (Plus)
PET bottles sparkling wine and wine piercing and filling device

Filling mode Pressurized filling from closed and open packages Pressurized filling from closed packages
Compressed 7.5 bar rel. ±0.5 bar (109 ±7 psi) for sparkling wine
6 bar rel. ±0.5 bar (87 ±7 psi)
gas supply 3 bar rel. ±0.5 bar (44 ±7 psi) for wine
Package types Glass bottles: 0.2 L to 1.5 L Glass bottles | cans | PET bottles
Ambient temperature 0 °C to +40 °C (+32 °F to +104 °F)
Dimensions 320 mm x 370 mm x 550 mm (12.6 in x 14.6 in x 21.7 in) 190 mm x 270 mm x 670 mm (7.5 in x 10.6 in x 26.4 in)
Weight 12.3 kg (27.1 lbs) 10.1 kg (22.3 lbs)
©© 2019
2017 Anton
Anton Paar
Paar GmbH
GmbH | All rights reserved.
Specifications
Specifications subject
subject to change without notice.