Banu Örmeci
Department of Civil and Environmental Engineering, Carleton University, 1125 Colonel By Drive, Ottawa ON, Canada K1S 5B6
Article history: Rheology is the science that deals with the flow and deformation of materials, and it has
Received 11 August 2006 become an important tool in optimizing sludge dewatering. This study presents torque
Received in revised form rheology data to illustrate two different methods for polymer optimization. The methods
19 December 2006 can be used to optimize the polymer dose and mixing intensity, as well as to select the best
Accepted 20 December 2006 performing product among a number of candidate polymers. The first method is used for
unconditioned sludges, and utilizes the peaks observed after the polymer injection. The
Keywords: second method is used for conditioned sludges and utilizes the entire torque-time
Rheology rheograms. Both methods were tested at the lab- and full-scale at the Plum Island Water
Sludge Reclamation Facility (Charleston, SC) using three different polymers. The methods were
Polymer able to optimize the polymer dose and full-scale mixing, and reduce the polymer
Conditioning consumption by 50% at the treatment plant. This translates into major savings for the
Dewatering utility. Furthermore, the results indicate that the total shear intensity imparted to sludge
Optimization during full-scale conditioning can be determined using torque rheology, and the jar-tester
shear can be matched to the total shear based on the rheological characteristics of sludge.
This information is essential to be able to simulate the full-scale mixing using a jar-tester
and to precisely determine the optimum polymer dose. The results of this study indicate
that well-defined rheological properties of sludge provide a reliable tool for the
optimization of conditioning and dewatering operations at wastewater treatment plants.
& 2007 Elsevier Ltd. All rights reserved.
14
13
12
0%
11
2.5%
Torque (mNm)
10 4%
5%
9 6%
7.5%
8
10%
7
5
0 20 40 60 80 100 120 140 160 180
Time (sec.)
Fig. 2 – Torque–time rheograms obtained from sludge samples conditioned with the Clarifloc C-311 polymer. The rheological
measurements were conducted according to Method 1.
ARTICLE IN PRESS
1246 WAT E R R E S E A R C H 41 (2007) 1243– 1252
Abu-Orf and Örmeci, 2005). The method involves one step, while the top of the peaks indicate the points where the
and rheological characteristics of samples are measured at network bonds rupture. Thus, the second half (decay phase)
300 RPM for 120 s after conditioning. The conditioning can be of the peaks, where the torque values start decreasing, can be
achieved using a jar-tester or a full-scale flocculator. The attributed to the deflocculation process and the decreased
method is useful in comparing the rheological and dewater- resistance to shear. After the flocs break up, the interaction
ing characteristics of already conditioned samples. Fig. 4 between them continuously decreases resulting in a decrease
illustrates typical results obtained using Method 2. in energy dissipation (Langer et al., 1994).
The rheograms illustrated in Fig. 2 can be analyzed in
2.6. Dewaterability measurements several different ways using the height of the peaks, width of
the peaks, the area under the peaks, the difference between
Dewaterability of sludge samples was characterized using the stabilized torque readings before and after the polymer
capillary suction time (CST) and gravity drainage tests. CST injection, or the area under the entire rheograms. This study
tests were conducted according to the Standard Methods investigates a possible relationship between the height and
(APHA, 1995). For the gravity drainage tests, 200 mL sludge the size of the peaks and the optimum polymer dose. The
samples were gravity-drained from an 11-mm Whatman paper rheograms in Fig. 2 indicate that in the underdose region the
for 10 min using a filtration unit (Millipore Sterifil Aseptic torque values increase in magnitude and the peaks increase
System, 47 mm), and the filtrate volume was measured. Cake in size when polymer dose is increased. This is because the
solids retained on the filter were measured using a microwave strength of the network bonds and the resistance of sludge to
moisture/solids analyzer (Denver Instrument Company, Mod- shear are higher after polymer addition. Fig. 3a shows results
el M2) at the treatment plant. CST and filtration tests were from CST and filtration tests. The lowest CST and the highest
conducted in duplicate. filtrate volume were measured at 5% polymer-to-sludge ratio,
which indicate that the optimum polymer dose is 5% (5 g/kg
DS) for this sludge. After the optimum dose was reached, the
3. Results and discussion torque values started to decrease in magnitude and the peaks
started to decrease in size (Fig. 2). The peak height and the
At the time of the study, the treatment plant was dosing a area under the peaks are illustrated in Fig. 3b. The area under
Mannich polymer (Clarifloc C-311) at 10% polymer-to-sludge a torque-time rheogram, or a peak in this case, has been
ratio (10 g/kg DS) before dewatering. Torque-time rheograms shown to be proportional to the total energy dissipation
from conditioned samples at increasing polymer doses are (Örmeci and Abu-Orf, 2005). The results indicate that the
illustrated in Fig. 2. These rheograms were obtained using peaks increase in height and size in the underdose region,
Method 1 and show the average of two rheograms. The and reach their maximum values at the optimum dose.
standard deviations were within 5% of the arithmetic means, Beyond the optimum dose, a decrease in the height of the
and error bars are not illustrated to keep the rheograms peaks and measured torque values was observed. It should
readable. In Step 1, sludge is mixed at 420 RPM for 10 s. to also be noted that the peaks eventually disappear due to
resuspend the settled material. The first peaks seen on the extended shear application, however the torque values
rheograms are influenced by the impeller speed and the measured at the end of the peaks (eg. 160–170 s) are still
initial turbulence created in the reservoir by the switched-on higher than those measured before the polymer addition (eg.
impeller, and may not accurately indicate the sludge char- 20–40 s) (Fig. 2). This indicates polymer addition increases the
acteristics, degree of flocculation or optimum polymer dose overall strength or resistance of sludge to shear even after
(Örmeci et al., 2004). Step 2 provides 40 s of stabilization time flocs are destroyed.
for the torque measurements (from 10 to 50 s) and serves as a The treatment plant was dosing polymer at 10% polymer-
baseline reading for the unconditioned sludge samples. At the to-sludge ratio (10 g/kg DS) before dewatering. The cake solids
end of Step 2, polymer is injected into the sludge through the concentration at this polymer dose was 18%. After the lab-
ports of the Floccky reservoir (Fig. 1b), which provides an scale testing illustrated in Figs. 2 and 3, it was clear that the
opportunity to observe both the flocculation and the defloc- plant was overdosing sludge. The polymer dose was de-
culation phases. Concentric-cylinder rheometers allow the creased to 5% (5 g/kg DS) at the full-scale, and 18% cake solids
observation of the deflocculation phase only. Right after content was maintained at this dose. The treatment plant
polymer injection, a steep peak is observed in torque read- now can achieve the same cake solids concentration and good
ings, which is due to the formation of flocs and the increased centrate quality only by using half of the polymer dose that it
resistance of the sludge network to shear. Unlike the first used to use. This resulted in 50% reduction in polymer
peak, this second peak is not affected by the initial turbulence consumption, and major savings for the treatment plant.
and exhibits good reproducibility. Michaels and Bolger (1962) Once the optimum dose was determined and confirmed
attributed the energy dissipated within a flocculated suspen- with the full-scale testing, the next step was to optimize the
sion to three separate processes. Energy is required to (1). operational parameters of the full-scale flocculant. The
Deform and stretch the network structures, (2). Break up the flocculant was operated at 200 RPM when the polymer was
bonds between flocs, and (3). Dissipate viscous energy. Based dosed at 10%, however no full-scale testing of the optimum
on the work of Michaels and Bolger (1962), Langer et al. (1994) flocculant speed was previously conducted. During the full-
explained the formation of peaks by the existence of an scale testing, the polymer dose was set at 5% and the
elastic network, where the high energy dissipation after flocculant speed was increased in 50 RPM increments. Condi-
polymer addition is due to the deformation of the network tioned sludge samples were collected right after the sludge
ARTICLE IN PRESS
WAT E R R E S E A R C H 4 1 (200 7) 124 3 – 125 2 1247
160
a
140
120
100
80 CST (sec.)
Filtrate Volume (mL)
60
40
20
0
0 2 4 6 8 10 12
25
b
20
15
0
0 2 4 6 8 10 12
% Polymer Ratio
Fig. 3 – (a) Results from the CST and filtration tests indicate that the optimum polymer dose is at 5% (5 g/kg DS). (b) The height
of the peaks and the area under the peaks are maximum at the optimum polymer dose.
stream left the flocculant, and rheological measurements cake solids were measured at 300 RPM. The observed decrease
were conducted according to Method 2. Cake solids concen- in the measured torque values at 300 RPM, supported by the
tration and supernatant quality were monitored. Results from results from the dewaterability tests, indicates that 300 RPM is
the rheological measurements and dewaterability tests are the optimum flocculant speed and sludge is conditioned best
illustrated in Fig. 4 and Table 1. The measured torque values at this flocculant speed when polymer dose is 5%. Örmeci and
were lowest for the unconditioned sludge samples as Abu-Orf (2004) and Abu-Orf and Örmeci (2005) reported a local
expected. At 250 RPM, the torque values were around decrease in the measured torque and totalized torque values
7.4 mN m, but decreased to around 6.8 mN m when mixing at the optimum polymer dose during polymer conditioning
speed was increased to 300 RPM. When the flocculant speed tests. The decrease in the measured torque values was
was increased to 350 and 400 RPM, measured torque values attributed to the release of free water at the optimum dose
continued to increase to 7.8 and 8.4 mN m respectively. Sludge and the decrease in the drag force due to the flocculation of
conditioned at 300 RPM dewatered best compared to the other particles, which in turn would decrease the resistance of
samples (Table 1). The lowest CST, highest filtrate volume and sludge to the applied shear and result in lower torque values
ARTICLE IN PRESS
1248 WAT E R R E S E A R C H 41 (2007) 1243– 1252
12
10
0%, 0 RPM
8
5%, 250 RPM
Torque (mNm)
0
0 20 40 60 80 100 120 140
Time (sec.)
Fig. 4 – Rheograms from sludge samples conditioned at different mixing speeds using the full-scale flocculant. The
rheological measurements were conducted according to Method 2. The polymer was Clarifloc C-311, and the polymer dose
was 5% (5 g/kg DS).
18
16
14
12
Torque (mNm)
3%
10 5%
6%
8 7.50%
10%
6
0
0 20 40 60 80 100 120 140 160 180
Time (sec.)
Fig. 5 – Torque–time rheograms obtained from sludge samples conditioned with the Clarifloc C-9545 polymer. The rheological
measurements were conducted according to Method 1.
Results from the three polymers (C-311, C-9545 and SE-914) flocculant. Since the polymer dose and the rheograms of the
tested indicated that all three polymers performed well with conditioned sample were already known, what was unknown
this sludge and produced good dewaterability. The emulsion was the mixing intensity imparted by the full-scale floccu-
polymers (C-9545 and SE-914) were preselected by the lant. If a raw (unconditioned) sludge sample is conditioned at
polymer manufacturer based on the chemistry of the the same polymer dose (5%), and the mixing intensity is
products and their long-term experience with the dewatering varied such that similar rheograms are obtained from the
operation at this treatment plant. Even though the emulsion sample, it would be possible to determine the jar-tester
polymers performed well, they did not provide a significantly mixing speed and time that would simulate the full-scale
higher performance compared to the Mannich polymer (C- mixing. Fig. 8 shows that the rheological characteristics of a
311), and the treatment plant decided to continue using the 500 mL sample mixed at 100 RPM for 30 s, 100 RPM for 60 s, and
Mannich polymer in their dewatering operations. 200 RPM for 30 s. The rheological characteristics of the sample
The final task was to provide a tool to the treatment plant that was mixed at 200 rpm for 30 s were very similar to the
operators to keep their dewatering operations at the optimum rheological characteristics of the sample mixed in the full-
on a daily basis. Sludge characteristics change over time, scale flocculant. Both samples dewatered similarly as well
which requires readjustment of the polymer dose. Conven- (CST values were 6.6 and 6.9 s respectively). This simple test
tional jar tests are typically used for the determination of provides a valuable tool to the treatment plant operators to
optimum dose at the lab-scale, however the mixing condi- simulate their full-scale mixing with the jar test experiments,
tions used in a jar test experiment are very different from and to accurately predict the polymer dose that would
those experienced in the full-scale flocculants. In fact, as generate the highest cake solids at the full-scale.
reported by Novak (1990) when polymer conditioning tests Use of rheological measurements for the optimization of
were conducted using a conventional jar-test apparatus, dewatering operations provides additional insights into
required doses were almost always unpredicted. In order to sludge properties, behavior and dewatering that cannot be
accurately determine the optimum polymer dose at the lab- obtained with the traditional capillary suction time (CST) and
scale, the jar-test mixing conditions must be matched to the specific resistance to filtration (SRF) tests. CST and SRF
full-scale mixing conditions. This, however, is quite a parameters are not indicative of material properties of sludge
challenge since there is no good way of directly measuring and they only allow relative predictions (Dentel et al., 2005).
the total mixing intensity that the sludge network is exposed Rheological parameters, on the other hand, are indicative of
to during full-scale mixing. An alternative is to use indirect material properties and provide not only descriptive but also
methods, such as rheological characteristics of sludge, to predictive tools (Dentel et al., 2005). Method 1 presented in
match the jar-test mixing conditions to that of the full-scale this study provides several advantages. First, it is directly
mixer. Previous results indicated that the optimum polymer applied to the unconditioned sludge. Thus, it eliminates the
dose for this sludge was 5% and the optimum flocculant need for the conditioning step as well as the effect of mixing
speed was 300 RPM (Figs. 2, 3 and 4). Fig. 8 shows the average on the polymer dose and dewaterability. Second, the method
of two rheograms obtained from a sludge sample conditioned allows direct observation of the effect of polymer, and the
at 5% polymer and 300 RPM mixing speed using the full-scale flocculation and deflocculation phases. The method allows
ARTICLE IN PRESS
1250 WAT E R R E S E A R C H 41 (2007) 1243– 1252
160
a
140
120
100
CST (sec.)
80 Filtrate Volume (mL)
60
40
20
0
0 2 4 6 8 10 12
40
35
b
30
25
Peak Torque (mNm)
15
10
0
0 2 4 6 8 10 12
% Polymer Ratio
Fig. 6 – (a) Results from the CST and filtration tests indicate that the optimum polymer dose is at 6% (6 g/kg DS). (b) The height
of the peaks and the area under the peaks are maximum at the optimum polymer dose.
16
14
12
10
Torque (mNm)
3%
4%
8 4.5%
5%
6 6%
7%
4
0
0 20 40 60 80 100 120 140 160 180
Time (sec.)
Fig. 7 – Torque–time rheograms obtained from sludge samples conditioned with the SE-914 polymer. The rheological
measurements were conducted according to Method 1.
10
7
Torque (mNm)
0
0 20 40 60 80 100 120 140
Time (sec.)
Fig. 8 – Rheograms obtained from samples conditioned using the full-scale flocculant and the jar tester according to Method
2. 200 RPM jar-tester speed and 30 s mixing time simulates the full-scale mixing, and produces sludge with similar
rheological characteristics.
digested sludge and several different Mannich, emulsion, and whether the presented methods can be applied to other
dry polymers. Preliminary results from these tests indicate sludges as well.
that multiple peaks might be observed after the injection of
polymers, particularly in the overdose region. The chemical
compatibility of the polymer and sludge appears to influence 4. Conclusions
the shape, size, and formation of the peaks. Further testing is
necessary to have a better understanding of the mechanisms 1. This study presents two methods that are based on torque
involved behind the formation and destruction of the peaks rheology and that can be used for the determination of the
(flocculation and deflocculation phases), and to determine optimum polymer dose and mixing conditions as well as for
ARTICLE IN PRESS
1252 WAT E R R E S E A R C H 41 (2007) 1243– 1252
the selection of the best performing polymers. The first Chung, J.T., 1986. Torque rheometer technology and instrumenta-
method is used for unconditioned sludge, and utilizes the tion. In: Cheremisinoff, N.P. (Ed.), Encyclopedia of Fluid
peaks observed in the torque readings after polymer Mechanics: Rheology and Non-Newtonian Flows. Gulf Pub.
Co., Houston, USA.
injection. The second method is used for already condi-
Dentel, S.K., Ayol, A., Filibeli, A., 2005. Modern rheometric
tioned sludge and utilizes the entire torque-time rheograms.
characterization of sludges. J. Residuals Sci. Technol. 2 (4),
2. Torque rheology can be used to determine the shear 233–240.
intensity imparted to sludge during full-scale conditioning. Firth, A.B., Hunter, J.R., 1976. Flow properties of coagulated flow
This information is useful in identifying the jar-tester speed suspensions—III. The elastic flow model. J. Colloid Interface
and mixing time that simulates the full-scale mixing. Sci. 57 (2), 266–275.
3. The measurement of well-defined rheological properties Langer, S.J., Klute, R., Hahn, H.H., 1994. Mechanisms of floc
provides a more reliable analysis compared to empirical formation in sludge conditioning with polymers. Water Sci.
Technol. 30 (8), 129–138.
tests used for characterizing wastewater sludges, and can
Michaels, S.A., Bolger, C.J., 1962. The plastic flow behaviour of
be used as a control parameter for the optimization of flocculated kaolin suspensions. Indus. Eng. Chem. Fund. 1 (3),
conditioning and dewatering operations at wastewater 153–162.
treatment plants. Novak, J.T., 1990. The effect of mixing on the performance of
sludge conditioning chemicals. Water Supply 8, 53–60.
Novak, J.T., Predenville, J.F., Sherrard, J.H., 1988. Mixing intensity
Acknowledgment and polymer performance in sludge dewatering. J. Environ.
Eng. 114 (1), 190–198.
The author thanks Mr. John (Jake) Earle and the personnel of Otsubo, Y., Umeya, K., 1984. Rheological properties of silica
the Plum Island Water Reclamation Facility for their assis- suspensions in polyacrylamide solutions. J. Rheol. 28 (2),
95–104.
tance during the full-scale testing.
Örmeci, B., Abu-Orf, M., 2004. Estimation of optimum polymer
dose using the area under a torque-time rheogram (totalized
R E F E R E N C E S torque). In: Proceedings of the IWA World Water Congress,
Marrakech, Morocco. September 19–24, 2004.
Örmeci, B., Abu-Orf, M., 2005. Protocol for measuring comparative
Abu-Orf, M.M., Dentel, S.K., 1997. Effect of mixing on the sludge network strength—relation to dewaterability. ASCE J.
rheological characteristics of conditioned sludge: full-scale Environ. Eng. 131 (1), 80–85.
studies. Water Sci. Technol. 36 (11), 51–60. Örmeci, B., Abu-Orf, M., 2006. Using torque rheology for the
Abu-Orf, M.M., Dentel, S.K., 1999. Rheology as a tool for polymer identification of the optimum polymer dose and the best
dose assessment and control. ASCE J. Environ. Eng. 125 (12), performing polymer. J. Residuals Sci. Technol. 3 (4), 227–232.
1133–1141. Örmeci, B., Cho, K., Abu-Orf, M., 2004. Development of a
Abu-Orf, M.M., Örmeci, B., 2005. Sludge network strength using laboratory protocol to measure network strength of sludges.
rheology and relation to dewaterability, filtration and thick- J. Residuals Sci. Technol. 1 (1), 35–44.
ening—laboratory and full-scale experiments. ASCE J. Environ. Slatter, P.T., 1997. The rheological characterisation of sludges.
Eng. 131 (8), 1139–1146. Water Sci. Technol. 36 (11), 9–18.
APHA, American Public Health Association, American Water Werle, C.P., Novak, J.T., Knocke, W.R., Sherrard, J.H., 1984. Mixing
Works Association, and the Water Environment Federation, intensity and polymer sludge conditioning. ASCE J. Environ.
1995. Standard Methods for the Examination of Water and Eng. 110 (5), 919–934.
Wastewater. 19th ed., Washington, DC. Yen, P.-S., Chen, L.C., Chien, C.Y., Wu, R.-M., Lee, D.J., 2002.
Campbell, H.W., Crescuolo, P.J., 1982. The use of rheology for Network strength and dewaterability of flocculated activated
sludge characterization. Water Sci. Technol. 14, 475–489. sludge. Water Res. 36, 539–550.