You are on page 1of 17

MTN-Irancell

Flexi EDGE Base Station

Amirsina Saaedi
Tehran 30.11.2011

I insert classification level


1 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi BTS installation options

Stacked Wall Pole Flexi BTS cabinet


installation installation installation installation

unique reducing
multiradio
costs
Soc Classification level
BTS
Flexi BTS platform:
Novel approach for GSM/EDGE/WCDMA/HSPA/WiMAX BTS sites

BTS configurations are built with weather-proof


modules; capacity is expanded by adding modules and
using software license keys Flexi
Same modules used for all site types EDGE BTS
• Indoor and outdoor
• Micro- and macrocellular 4+4+4
860mm
• From 1 to 216 TRX configurations
Modules can be installed to walls, poles, stacks,
19”racks or Flexi BTS cabinets
Common Flexi platform brings modularity to 2+2+2
GSM/EDGE, WCDMA/HSPA and WiMAX BTS sites 600mm
Nokia Siemens Networks is the first and only vendor to
adopt the novel modular approach

Soc Classification level


3 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi BTS
A BTS built with modules

Cabinets are not needed with a module-based BTS


• Modules are in weather-proof casings with Standard module (3HU)
front and back covers (IP55)
• Casings allow removal of the modules from 133 mm
the stack
• Temperature range: 422* -
-35°C …+50°C; temporarily +55 °C 560 mm
Modules can be installed in cabinets 447 mm
• Casings are not used in cabinet installations
Modules are small and light-weight Weight approx 15-25 kg

• One person can transport and install BTS * 422 mm depth for cabinet-installed
without using lifting equipment modules

HU = 44.4 mm

Soc Classification level


4 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi EDGE BTS:
simpler architecture with fewer units

Functionality of main modules with bypass or wideband combining

Dual duplexer module Filtering, duplexing, Bias-Ts


Logical
Sector Dual TRX module GSM/EDGE RF Wideband combiners
module
Baseband Processing

System module
Ethernet &
(transport) Control signaling DC Power

Abis IF Transport sub-module


Optional
sub-module

Soc Classification level


5 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi EDGE System Module (ESMA, 3HU)
Support for 6 DTRX (e.g. 4+4+4)

PDU (power distribution unit)


48V to 6 DTRX’s Synchronization
PDU (power
distrib. unit)
48V intake

Ext Alarm &


6 x Gb Ethernet Control:
to DTRX 12 alarm inputs
6 control outputs

Interchangeable
Transport module:
Site support system, 8xE1, 8xE1/T1 or 2x
Flexi Power system Alarms (FPA), Flexbus
Aux equipment Q1,
Local Management Port (LMP)

HU = 44.4 mm

Soc Classification level


6 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi EDGE Sector Module (3HU)
Sector module is a logical unit consisting of 2 building blocks:
• Dual TRX (DTRX) module
• Dual duplexer module

One Sector module is needed per sector, fits into 3HU casing

Dual duplexer module

Dual TRX module

HU = 44.4 mm

Soc Classification level


7 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi EDGE Dual Duplexer Module (ERxA, 1HU)

Dual duplexer (DDU) module together with Dual TRX create a logical Sector module
• Typically 1 DDU per sector is needed. More than 1 DDUs per sector are used
with some coverage applications
• DDU is connected to a DTRX via cable (cable comes with the DDU). In stack
configuration, DDU shares same casing with that DTRX
DDU provides
• Duplex functionality to combine TX and RX signals to same antenna feeder
• Receive signal multicoupling
• 2 antenna connections (for 1 or 2 sectors)
– 2 TX inputs and 4+4 RX outputs (4 RX from antenna 1 and 4 RX from antenna 2)

Ant 1 Ant 2
TX 1 RX for 4xRX 1 4xRX 2 RX for TX 2
external BTS external BTS HU = 44.4 mm

Soc Classification level


8 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi EDGE Dual TRX Module (EXxA, 2HU)
Dual TRX module (DTRX) is a 2 carrier TRX unit, used as:
• a stand alone TRX module (2 TRX capacity)
• or a Sector module with the Dual duplexer module (2 TRX capacity)
• or as Double Power TRX, DPTRX (1 TRX capacity)
• or for Intelligent Downlink Diversity, IDD (1 TRX capacity)

Phase feedback from WBC (DPTRX)


1xDTRX-DDU 1xPower TX 1 4xRX
TX 2

1xBus

0-2xWideband combiners

HU = 44.4 mm

Soc Classification level


9 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi EDGE System Extension Module (ESEA, 3HU)

System extension module is required for large BTS configurations


(System module for 1-6 DTRX, System extension module for 7-12 DTRX in BSS13)
System extension module is always required for RTC configurations
• All TRXs must be connected to same system module for BB hopping
The functionalities of System extension module:
• Power distribution to additional modules (i.e. DTRX 7-12). Power distribution part has six 48V
outputs
• Providing 12 Ethernet and synchronization connections to DTRX (DTRX 1-12) and 1 connection to
System module

PDU (power distribution unit) Ethernet to System module


PDU (power distribution
6x48V to other modules
unit) 48V intake

12x Ethernet to DTRX

HU = 44.4 mm

Soc Classification level


10 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi EDGE BTS modules

3 HU modules
• For stand alone and cabinet installations
• 133 x 447 x 560 [mm], (H x W x D)
• Weight 10 … 20 kg
(+ 6 kg for casing and covers)
2 HU modules
• For stand alone and cabinet installations
• 89 x 447 x 560 [mm], (H x W x D)
• Weight 10 kg
(+ 5 kg for casing and covers)
560 mm 4 HU module (RTC only)
447 mm • Only for cabinet installations
• 171 x 447 x 415 [mm], (H x W x D)
• Weight 28.5 kg
In cabinet installations max module depth is 422
mm

Soc Classification level


11 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Nokia Flexi EDGE BTS: from small to large
configurations
Flexible capacity increase from small to very large configurations
• 1 to 24 TRX in 1-6 sectors under 1 BCF
• up to 216 TRX per site
High site capacities possible even without a cabinet
Frequency bands
• GSM 800, 900, 1800 and 1900
• Dual band configurations with single system module

Min configuration Max configuration / BCF


1-2 TRX , 2 modules 24 TRX, 14 modules
Soc Classification level
12 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
2-way Wideband Combining with 2-way RX diversity

Example: 4 TRX/cell
Dual TRXs Combiners

TX1 WBC Antenna


Main
RX1 Div Dual Duplexer
Div X
Main

Duplexer
RX2 Div LNA+
Multi-
LNA
TX2 coupler

LNA+

Duplexer
Multi-
LNA
TX3 coupler
Main
RX3 Div
Div
RX4 Main
Div
TX4 WBC

Soc Classification level


13 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi EDGE module cover and installation

Module casings and front and rear covers


are required when modules are installed
without cabinet
Cooling fans are attached to the module
A plinth is required for installation when 1. Rear cover (plastic)
cabinet or 19” rack is not used
2. Casing (metal)
• Same plinth for floor, wall and pole
mounting kit
Common grounding point is used in all
configurations: 3. Front cover
(plastic)
• plinth in module installations
– grounding with ground cables
• cabinet in cabinet installations Plinth (FMFA) for
stack, pole or wall
installation

Soc Classification level


14 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi BTS cabinet
Cabinet can simultaneously house GSM/EDGE, WCDMA/HSPA, WiMAX and BBU
modules
• There are no limitations on how to mix GSM, WCDMA and WiMAX in the
cabinet
• In GSM/EDGE up to 24 TRX configurations per cabinet
Optional Flexi Cabinets for indoor and outdoor installations
• Open 19” mechanics with 1 HU fixing steps for flexible module installations
• No motherboards or electronics (fans etc)
• Not part of EMC shielding
• Only front cabling
• Module casings and covers are not used
• Cooling fans remain in modules
• Modules are grounded via rack
• Same cabinet fixing points as with Flexi BTS
Nokia Siemens Networks UltraSite and Talk Family Outdoor Cabinet

Soc Classification level


15 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Flexi BTS cabinets

Indoor Outdoor
36HU, 62kg 40HU, 70kg

1800 1550

600 770
600 770

Soc Classification level


16 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011
Thank you.

I insert classification level


17 © Nokia Siemens Networks MTN-Irancell – Flexi EDGE BTS - Amirsina Saaedi – 30.11.2011

You might also like