You are on page 1of 2

Wagobox Wago Terminals Wagobox

Pushwire Terminal Blocks a junction box


innovation
773-102 773-104 773-106 Quick, easy to fit, compact and configurable
2-Pole Pushwire 4-Pole Pushwire 6-Pole Pushwire
Conductor sizes: Conductor sizes: Conductor sizes:
A multipurpose electrical junction enclosure that has 0.75mm² - 2.5mm² Solid Core 0.75mm² - 2.5mm² Solid Core 0.75mm² - 2.5mm² Solid Core
1.5mm² - 2.5mm² Stranded Core 1.5mm² - 2.5mm² Stranded Core 1.5mm² - 2.5mm² Stranded Core
been designed for use with the Wago 222 and 773 series Current rating: 24A Current rating: 24A Current rating: 24A
terminal blocks. The Wagobox is easier to use, quicker Voltage rating: 400V/4KV Voltage rating: 400V/4KV Voltage rating: 400V/4KV
to fit and more configurable than any other junction
box of it’s size. It is the first of its type and redefines the
standard for general purpose domestic and commercial
junction boxes.
Fast 773-108 773-173
8-Pole Pushwire 3-Pole Pushwire
Installing a Wagobox can take as little as 25% of the
Conductor sizes: Conductor sizes:
time it takes to install a screw terminal style junction box. 0.75mm² - 2.5mm² Solid Core 2.5mm² - 6.0mm² Solid Core

Cables are cut to size and connected outside the box. 1.5mm² - 2.5mm² Stranded Core 2.5mm² - 6.0mm² Stranded Core
Current rating: 24A Current rating: 41A
No awkward connections in a small space. Voltage rating: 400V/4KV Voltage rating: 400V/4KV

Easy to use
No screws or fiddly clamp bars.
Cables slot into position and are secured in seconds. Lever Clamp Terminal Blocks
Uses simple to fit Wago pushwire and lever clamp
terminals.
Compact
Dimensions: 39mm x 44mm x 108mm.
Supports up to 6 cables.
Fits through a 60mm diameter spot light hole. 222-412 222-413 222-415
2-Pole Cage Clamp 3-Pole Cage Clamp 5-Pole Cage Clamp
Configurable Conductor sizes: Conductor sizes: Conductor sizes:
0.08mm² - 2.5mm² Solid Core 0.08mm² - 2.5mm² Solid Core 0.08mm² - 2.5mm² Solid Core
The integrated cable clamp can secure flex and 6242Y 0.08mm² - 4.0mm² Stranded Core 0.08mm² - 4.0mm² Stranded Core 0.08mm² - 4.0mm² Stranded Core
and 6243Y cables from 1.0mm² to 6.0mm² twin and earth. Current rating: 32A Current rating: 32A Current rating: 32A
Voltage rating: 400V/4KV Voltage rating: 400V/4KV Voltage rating: 400V/4KV
Robust cable grippers that can be configured in
seconds to grip cables up to 8.00mm in diameter.
Mix and match the Wago 222 and 773 terminal blocks
to suit the job with up to 24 individual terminations. ®

Professional
Complies with BSEN60670-22. T: +44 (0) 1353 666 011 F: +44 (0) 1353 669 038 ®

Meets all the requirements of the 17th Edition of BS7671 W: www.connexbox.com E: sales@connexbox.com
Installation Instructions 3 Connect the cables together 6 When fitting the cables into the cable clamp the
to make the circuit. sides of the box need to be eased apart to make an
The Wagobox enclosure is designed for use with the 222 opening. It is normal for the entrance to be splayed
and 773 series of terminal blocks. The Wagobox is rated apart with the cables in place.
up to 400V and can support conductor sizes from 0.08mm2
to 6.0mm2. The maximum number of supported individual
conductor connections is 24 at 1.0mm2 to 6 at 6.0mm2. 4 .8
1459
o. 08 -0001
P .N 5
E N T AP N 98704
AT IG
If you are in anyway unsure about any of the following steps or GB P GD DES
RE

how to connect the circuit, then consult a qualified electrician.


94.8 94.8 94.8 94.8
145 01 145 01 145 01 145 01
. 08
- 0 0 clampPby . 08
- 0 0 the black o 5-00 . 08 . 08
4 Configure . N ocable
the
P 045 . N oputting
045 P . N plastic
04 P .No 045-00
T AP 987
N IGN T AP 987
EN N T AP 987
N N NT
AP 987
N
AT E PAT D E S I G AT E D E S I G AT E D E S I G
B P GD DES
Ggrippers in the correct
G B E G Dposition for B P Gsize
Gthe D of cableG B P G D used
being
Incredibly Simple... RE R RE RE

a b c d
The Wagobox is easy to use and fast to fit, just follow the
steps below and see how the Wagobox will revolutionise
the way you work. 7 Try to keep cables of a similar size together in the
same slot and simply push them into the slot as far
1 Strip back the outer protective sheath of the cable a Tight Position for small cables such as 1.0 and 1.5mm2 twin as they will go.
60mm - 80mm. and earth.
b Offset Position for medium size cables such as 2.5 and 4.0mm2 Once all the cables are installed, firmly squeeze the
60 - 80mm
twin and earth. gripper end of the box together and snap shut the lid
c No Gripper required for large cables such as 6.0mm2 twin and earth so that it is held securely by the 3 locking tabs.
d Optional extra gripper position for extra grip on very small 2 core flex
(May require the purchase of an additional gripper)

9 4 .8
2 Select the appropriate 773 Pushwire 5 Arrange your terminals and slide them into the . 08
145 01
.N o 5 - 0 0
T APP 98704
E N S IG N
PAT
773 or 222 terminal
E
GB EGD D
Solid receptacles. R

block for the circuit to 12-13mm

9 4 .8
be connected . . 08
145 01
P .N o 0 4 5 - 0 0
A P 8 7
Strip insulation to E N T S IG N 9
PAT E
GB EGD D
1.0 - 2.5mm2 R
recommended length.

773 - 173 Pushwire 222 Lever Cage Clamp


Solid Solid

Stiff Stiff
Stranded Stranded
12-13mm
Flex

2.5 - 6.0mm2 .05 - 4.0mm2 9-10mm

You might also like