SOLSMART 1450
GENERAL SAFETY PRECAUTION
This user manual contains the most important information on operating the
system safely. Each person concerned with the installation, commissioning,
maintenance and operation of V-Guard Solar Hybrid UPS must have read and
understood the entire user manual.
IMPORTANT INSTALLATION INSTRUCTION
Do not connect the Output of UPS to main line output as this may damage the
UPS. Only connect required Fan, Light point, TV Point and 1-2 extra 6A socket for
your heavy load (mixers, grinders, room cooler) with in the specified rating of
product.
• CONTROL DUPS FROM YOUR PHONE - The V-GUARD Synergy Smart DUPS
easily syncs with your smart phone through Wi-Fi or Bluetooth. Once your
product is registered on the V-Guard Smart app, you can control the DUPS
system through your mobile from anywhere.
STATUS PAGE :
1800
SOLSMART
SOLAR PAGE :
Ÿ Can give information about product installation
location.
Ÿ Real time solar generation can be checked.
Ÿ User can monitor solar savings details of Today,
Yesterday and Total based on solar utilization. User
can also calculates savings based on tariffs input
given in app.
Ÿ User can monitor 5 days weather forecast and plan
accordingly for power usage.
SOLSMART
1800 ç ALARM SETTINGS PAGE :
SOLSMART
1800
User can set advance
battery low alarm, mains
change over buzzer and
overload level as per their
requirement.
è USAGE TRENDS :
Ÿ Provides graphical
representation of running
load on the DUPS.
Ÿ Provides power failure
history for last 7 days.
SWITCH SETTINGS :
SOLSMART
1800
Ÿ Mode selected option allows user to set the DUPS to
UPS / Normal / Equipment mode**. UPS mode is
useful for critical IT loads. Equipment mode is
useful for home appliances having SMPS.
option will be locked. Unlock button is provided and will remain active for next
30 mins after unlocking.
Ÿ Day time load usage mode is useful for working family where
nobody is available at home during day time. If you have selected
“No” and selected Power saver at Max mode, It will cut DUPS mains
in night to discharge battery to certain level for next day charging
through solar.
Amazon Alexa and Google Home connectivity helps you to control your
device using voice from anywhere as per convenience.
* All the readings and time shown in the App are calculated on STC and can be
affected by various operating conditions present at site. Value shown in App
should be taken as reference only, actual results may have variations as compared
to readings shown in the App.
CONFIGURATION PROCEDURE
In order to configure your mobile with SolSmart DUPS, press and hold the DUPS
ON/OFF switch continuously for 10 seconds (Approx) until 3rd beep sound occurs.
ON/OFF switch LED starts to blink. Now Press RECONFIGURE DUPS icon on APP
with in 15 minutes and configure DUPS as per the instructions given in the APP
SOLSMART 1450
Fig (1)
A. UPS MODE LED: UPS mode is set to run PC load. UPS mode LED glows when
the unit is in UPS mode, blinks if it is in Equipment mode and off if it is in
Normal mode. By default unit will be in Normal mode. In order to change the
mode from NORMAL to UPS or to Equipment mode, press the front panel
ON/OFF switch for 5 seconds continuously until second beep sound occurs
(Not applicable when water topping reminder indication active).
B. MAINS ON LED: Glows steady when the mains is available within the
normal limits (90-290V in NORMAL mode, 140-290V in EQP mode and 180-
260V in UPS mode) and blinks when mains out of range / mains force cut due
to solar and off when mains not available (If Mains voltage goes below the
specified voltage range, i.e. Low cut condition - 2 blinks, If Mains voltage
goes above the specified voltage range, i.e. High cut condition - 3 blinks).
C. CHARGE LED: This will blinks when batteries are charging and Glows steady
when batteries are charged. During day time it will be OFF if 100% battery
charging through solar ( For Tubular battery selection - 3 blinks, for Flat Plate
battery selection - 2 blinks & for Local battery selection - 1 blink).
D. BACKUP LED: This LED will glow steady when the UPS is in backup mode
due to mains failure or out of range or mains force cut stage when solar is
available and power saver mode is selected.
E. LOW BATT LED: Blinks during low battery warning and glows steady after
low battery shutdown with buzzer indication.
F. OVERLOAD LED: Blinks when the loading is above it’s specified capacity
and blinks with continuous buzzer after overload shutdown. Glows steady
after short circuit in output side. After 5 times of retrying overload protection
shutdown will happen. Again press ON/OFF switch to RESET/ turn ON the
product. It is advisable that connected loads in bypass should not be more
than the rated capacity of UPS.
G. SOLAR LED: Blinks when charging, glows after full charge and off when
solar is not available.
H. ON/OFF SWITCH: This switch can be used to make the unit ON/OFF and
this can be done by pressing the switch continuously for 1 second until a
beep sound occurs. BACKUP LED will be OFF when the unit is in OFF mode. If
theunit is in OFF mode, the load connected at the output will not work in the
event of mains failure, however charging will continue if mains is in normal
limit. The switch also works as a reset in an event of overload & low battery
shutdown. When the switch is in ON condition the switch glows and it will not
glow if the switch is OFF. This switch can be used for Normal, UPS and
Equipment mode selection. By default unit will be in normal mode. In order
to change the mode from Normal to UPS or from UPS to Equipment mode or
from Equipment to Normal mode press and hold the switch continuously for
5 seconds until second beep occurs. UPS mode LED glows when the unit is in
UPS mode, blinks when it is in Equipment mode and off if it is in normal
mode. Normal, UPS and Equipment mode can be selected by using APP also.
For this user has to go switch settings portion in the APP where user can
change the mode by touching the mode selected option.
LED Indications for some of the fault status of product is given below.
****UPS operation when mains RCB Trip : MAINS ON LED blinks and BACKUP
LED glows and there will be 5 times buzzer at 5 minutes interval during 20 minutes
of operation after that system goes off.
II. UPS BACK PANEL DESCRIPTIONS
34 5 7
1
2
6
SOLAR (25 VOC)
9 8
Fig (2)
1. MAINS RCB: This is connected in line with the MAINS input to UPS. This will
trip to disconnect the mains to save the product in case of short circuit at load
side or excess overload in mains mode. It is recommended to connect rated
capacity load through UPS to avoid unnecessary RCB tripping.
2. OUTPUT SOCKET: This is provided for connecting the loads that will run
through the UPS while power is not available. It is recommended to use ISI
marked plug on this socket.
3. POWER SAVER MAX/NORMAL SWITCH : This system is equipped with
a selection switch (power saver) on back panel to utilize the available solar
power as per user requirement. On Max position system will cut the grid
power and connected load will run on available excess solar power. In
NORMAL position solar power will be used to charge the battery. Maximum
power saver position is recommended to installation having lesser power cut
or in winter. Normal power saver position is recommended to the installation
having longer power cuts. By keeping power saver switch in Max position
user can select Night mode using App. This mode allows user to discharge
the battery during night time there by utilize the unit saved through solar.
4. HC & NC SELECTION SWITCH: This can be used to select the charging
current of UPS. Keep the switch in HC when using 135-230Ah battery and in
NC when using 80-120Ah battery. It is recommended to keep the switch in
NC for local battery.
5. TUB/FP/LOCAL SELECTION SWITCH: This is battery selection mode. If
the battery used is tubular type, select TUB (Tubular) mode. If the battery
used is flat plate type, then select FP (Flat Plate)mode. If the battery used is
any Local make, select LOCAL mode for optimum performance. This setting
is very critical and needs to be done within 30 minutes of installation. After
that the setting cannot be done without disconnecting the battery. Wrong
setting can deteriorate the UPS backup and can even cause damage to
battery.
6. MAINS LEAD: This is used to connect input mains supply to the UPS. Ensure
earthing drop between Input ‘Neutral’ and ‘Earth’ below 1V to avoid electric
shock due to earth leakage.
7. POSITIVE BATTERY WIRE: Connect the positive battery wire (red) of UPS
to positive terminal of battery.
8. NEGATIVE BATTERY LEAD: Connect the negative battery wire (Black) of UPS
to negative terminal of Battery.
9. SOLAR + & SOLAR - : This is provided for connecting solar panel to UPS. The
panel should be with in the recommended capacity. During installation, the
polarity of panel should be correct. Connect the +ve terminal (Red wire) of panel
to SOLAR + and -ve terminal (Black wire) of panel to SOLAR - of the UPS.
25 VOC,
800Wp Max
4. Switch on the front switch and check the output voltage in output socket. After
checking switch OFF the DUPS.
5. Only selected branches on D.B should be connected to DUPS output as shown in
fig. 6, overloading on DUPS can cause damage to product.
Distribution
Neutral Strip
Distribution
Neutral Strip
Refrigerator
Refrigerator
Iron box
Iron box
Fig 6 Fig 7
Iron box
Iron box
Earth Strip
Distribution
Neutral Strip
N
L
Fig 8
8. Switch on the mains of DUPS and check the working of load branches got
connected through DUPS. After checking, check the charging LED on display it
should blink as per mode and battery type selection. Get the mode & battery type
selected as per need and battery type installed.
9. After doing all the settings switch OFF the mains and switch ON DUPS and check
the connected load they should be powered up in battery mode.
10. After checking all the loads reconnect the mains to complete the installation.
SOLAR + SOLAR
25V VOC, 800Wp Option 1
25V VOC
160Wp } X 5 parallel
SOLAR +
25VOC, 880Wp
SOLAR
Option 2
25V VOC
110Wp } X 8 parallel
Fig 11
SOLAR + SOLAR
25VOC, 800Wp Option 3
25V VOC
200Wp } X 4 parallel
Fig 12
Note : It is recommended to keep minimum wiring length (not more than 30 feet)
between solar panel and UPS during installation.
Some possible load combinations for SolSmart 1250 / SolSmart 1450 is given below.
POSSIBLE LOAD COMBINATIONS FOR SOLSMART 1250 SOLSMART 1450
LOAD***** A B C D A B C D
TV (LED/LCD) 1 2 1 1 2 1
Tube Light 1 1 1 1 1 1
Fan 1 4 2 1 4 2
Room Cooler / Mixer Grinder 1 1
CFL/LED bulb upto 14W 3 8 4 2 3 8 4 2
Inverter Refrigerator 1 1
Water Pump 1
***** This load combination should be taken as reference only, actual load
capacity may vary with different brands.
****** Subjected to material and usage conditions.
Symptoms Possible cause Solution
Check if Battery low indication is present,
check the mains supply availability and
Battery low mains on indication at UPS. If again
Backup mode problem persists please contact V-Guard
but no output. care for further support.
Battery loose Tighten the battery connections properly.
connection
Poor battery Change your battery.
condition.
Turn off the UPS and reduce the load
Overload. connected to the system and turn on the
UPS again.
Remove all loads from the system and turn
ON the UPS to check whether the output is
Short circuit present. If output present, checkout the
related wiring for any kind of problem or
faulty equipment connected. Remove the
short circuit and run the unit.
Reduce the load connected to the system;
Mains mode press the button of MAINS RCB at the back
Overload / panel of UPS. If again the same problem
but no charging
Short circuit persist disconnect the entire load from the
and output.
system and check any problem or faulty
equipment connected in the wiring.
Press the button of the MAINS RCB at the
back panel of UPS. Switch OFF/ON the
MAINS ON LED front button to bypass mains immediately.
blinking with MAINS RCB trip. If MAINS RCB is not resetted, UPS will
buzzer sound. beep every 5 minutes to alert you for reset
of MAINS RCB. After 20 minutes (4
attempts) the UPS will shutdown to save
battery power.
Sl. No/
QR Code
PRN-MN-032-00