1 General
1.1 SCOPE
This calculation document covers the design of fixing arrangement of Bearing with the
super structure.
Material = Steel
Grade of Steel = E 250
Design Data
Steel
Yield Stress Fy = 250 N/mm"2
Modulus of Elasticity Estee I = 2.lx10"5 N/mm"2
Bending Stress in Steel = 250 N/mm"2
Concrete
Unit Weight of structural steel = 78.5 kN/m"3
So it is proposed that we may use an additional plate of grade E250of size 650mm* 550 mm*
32 mm to be placed between the top distribution plate and the bottom chord.
The Additional plate proposed for fixing the OWG with bearimgs, will be welded to the
distribution plate (lying at bottom) on all sides and top of fixing plate willbe bolted with the
bottom chord with 8 bolts M-22 of 8.8 grade.
Max. vertical load (ULS) coming from the Girder = 743.00 M.T.
89375 KN
8937.5 M.T.
Bearing strength of the proposed plate is more the maximum load coming on
the supports/ Bearing i.e. 7430 KN. Hence Safe
shear force resistance = Slip factor * No. of interfaces * Minimum Bolt value / FOS
228.08016 KN
of bearings having
The additional Plate of 32 mm thickness will be welded with the distribution plates
different thicknesses as shown in the table above. Minimum thickness is 26 mm
ontrac
tas
Plate size = 650*550 mm
Hence Okay
Strength of the end fillet weld will be the additional strength of the joint thus
providing more factor of safety.
actor