You are on page 1of 1

530 513

352 53 125 317 71 125

TYP 103 TYP 106


6 6

15
15
150 x 100 x 8 RHS 150 x 100 x 9 RHS

125 101 200 101 125

300

GROUT PAD
M20 x 320 HIGH STRENGTH

40
R
40

20 NOM
460

480
STEEL BOLTS (75 NOM

380
M20 x 320 HIGH STRENGTH 90

GROUT PAD
PROTRUSION) WITH NUT, THIN

630

5 FALL
20 NOM
NUT AND 4 THICK PLATE STEEL BOLTS (75 NOM

WASHER (TYP) 90 PROTRUSION) WITH NUT, THIN

330
5 FALL
NUT AND 4 THICK PLATE

WASHER (TYP)

940

940
1 400

1 400
80 x 80 x 20 DEEP FORMED 80 x 80 x 20 DEEP FORMED

1 200

1 200
RECESSES SHALL BE RECESSES SHALL BE

660
FILLED WITH GROUT FILLED WITH GROUT

490

920
THIS OUTER FACE MUST THIS OUTER FACE MUST

750
BE VERTICAL FOR INNER BE VERTICAL FOR INNER
NCF NCF NCF NCF
TRAFFIC BARRIER TYPE MBI TRAFFIC BARRIER TYPE MAI

180

180

180

180
M30 x 460 HIGH STRENGTH M30 x 460 HIGH STRENGTH

STEEL BOLTS (85 NOM STEEL BOLTS (85 NOM

PROTRUSION) WITH NUT, THIN PROTRUSION) WITH NUT, THIN

80

80

80

80
NUT AND 4 THICK PLATE NUT AND 4 THICK PLATE

WASHER (TYP) WASHER (TYP)


FINISHED DECK LEVEL FINISHED DECK LEVEL FINISHED DECK LEVEL

TYPE MAO TYPE MBO TYPE MCI

OUTER TRAFFIC BARRIER TYPE MAO SHOWN OUTER TRAFFIC BARRIER TYPE MBO SHOWN MEDIAN TRAFFIC BARRIER

INNER TRAFFIC BARRIER TYPE MAI SIMILAR INNER TRAFFIC BARRIER TYPE MBI SIMILAR

(PROVISION FOR CYCLISTS) (PROVISION FOR CYCLISTS)

GENERAL NOTES
0 100 200 300 400 500mm
SCALE OR AS SHOWN.
100 50

DESIGN ASSUMPTIONS:

MAXIMUM POST SPACING: 2 700mm.

POST SPACING TO SUIT PRECAST PARAPET UNITS, SAFETY SCREEN PANELS OR NOISEWALL PANELS AS REQUIRED.

CONCRETE EXPOSURE CLASSIFICATION: B1

MINIMUM 28 DAY COMPRESSIVE STRENGTH OF CONCRETE: 40MPa

10 x 10 CHAMFER SHALL BE USED AT TOP CORNERS OF CONCRETE PROFILE.


270 270 STEEL PLATE SHALL CONFORM TO AS/NZS 3678 - 250.

60 150 60 55 150 65 RECTANGULAR AND CIRCULAR HOLLOW SECTIONS SHALL CONFORM TO AS/NZS 1163 - C450LO.
2/60 x 4 PLATE x 60 WASHERS 2/60 x 4 PLATE x 60 WASHERS ALL FASTENERS MUST CONFORM TO THE REQUIREMENTS OF ROADS AND MARITIME SERVICES
10 240 20 15 240 15
WITH Ø24 HOLE AT CENTRE WITH Ø24 HOLE AT CENTRE QA SPECIFICATION B240.
FOR M20 BOLTS TYP OR TYP FOR M20 BOLTS TYP OR TYP HIGH STRENGTH STEEL BOLTS FOR STRUCTURAL ENGINEERING SHALL BE PROPERTY CLASS 8.8 TO AS/NZS 1252.

HIGH STRENGTH STEEL NUTS FOR STRUCTURAL BOLTING SHALL BE PROPERTY CLASS 8 TO AS/NZS 1252.
15

15

BOLTING CATEGORY FOR HIGH STRENGTH STEEL BOLTS SHALL BE 8.8/S IN ACCORDANCE WITH AS 5100.6.
20 THICK VERTICAL PLATE - TYP 20 THICK VERTICAL PLATE - TYP STEEL WASHERS, LARGE SERIES, SHALL CONFORM TO AS 1237.1, PRODUCT GRADE A.
105

105

ALL STEEL COMPONENTS SHALL BE HOT DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ROADS AND
2/Ø36 x 40 LONG 2/Ø36 x 40 LONG
MARITIME SERVICES SPECIFICATION B201.
SLOTTED HOLES SLOTTED HOLES
BOLTS NUTS AND WASHERS SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH AS 1214.

ALL WELDING SHALL BE SP IN ACCORDANCE WITH AS/NZS 1554.1.


330

120

300

330

120

300

ALL WELDING SHALL CONFORM TO AS/NZS 1554.1 WITH ADDITIONAL REQUIREMENTS AS GIVEN IN ROADS AND

MARITIME SERVICES SPECIFICATION B201.

WELDING SYMBOLS COMPLY WITH AS 1101.3.


105

105

2/60 x 4 PLATE x 60 WASHERS 2/60 x 4 PLATE x 60 WASHERS REINFORCEMENT NOT SHOWN. THE SIZE AND SPACING OF REINFORCEMENT MUST BE DETERMINED
WITH Ø36 HOLE AT CENTRE WITH Ø36 HOLE AT CENTRE BY THE DESIGNER.
FOR M30 BOLTS FOR M30 BOLTS DENOTES THE GROUT USED TO CONSTRUCT MORTAR PADS AND FILL FORMED RECESSES SHALL BE SHRINKAGE
15

15

2/Ø26 x 30 LONG 2/Ø26 x 30 LONG


COMPENSATED HIGH FLOW CEMENTITIOUS GROUT.
270 x 25 PLATE x 330 270 x 25 PLATE x 330
SLOTTED HOLES SLOTTED HOLES
MINIMUM COMPRESSIVE STRENGTH OF GROUT SHALL BE 40MPa.

GROUTING SHALL BE CARRIED OUT TO ENSURE THAT THE FORMED RECESSES ARE COMPLETELY FILLED AND THAT
BASE PLATE TYPE MAO BASE PLATE TYPE MBO
THERE ARE NO VOIDS UNDER THE BASE PLATES.
LARGE SERIES WASHERS TO SUIT BOLT SIZES SHOWN MAY BE USED INSTEAD OF PLATE WASHERS LARGE SERIES WASHERS TO SUIT BOLT SIZES SHOWN MAY BE USED INSTEAD OF PLATE WASHERS
SIDE FACES OF GROUT PADS SHALL BE VERTICAL AND FLUSH WITH EDGES OF BASE PLATES.

0 100 200 300mm 0 100 200 300mm THE FORMWORK FOR THE GROUT PADS SHALL REMAIN IN PLACE FOR A MINIMUM OF 3 DAYS AND CURING

COMPOUNDS SHALL BE APPLIED TO THE SIDES OF THE GROUT PADS AFTER THE REMOVAL OF FORMWORK.
100 50 100 50
THE UNDERSIDE OF THE BASE PLATES AND SIDE FACES OF SLOTTED HOLES SHALL BE PAINTED WITH TWO PACK

SURFACE TOLERANT EPOXY PAINT WITH A MINIMUM DRY FILM THICKNESS OF 100µm.

THE SLOPE OF THE CONCRETE AND STEEL POST EXTERNAL FACE IS TO BE DETERMINED ACCORDING TO URBAN

DESIGN REQUIREMENTS, BUT NOT EXCEED 1 IN 10 (5.7°).

STATUS
APPROVED FOR USE
STANDARD DRAWING ISSUED
ISSUE DATE

W.Ariyaratne TRAFFIC BARRIERS


REVISION ISSUE
DEC 2018
DIRECTOR BRIDGES AND STRUCTURES
SEND FEEDBACK ON THIS STANDARD

DRAWING TO:
MEDIUM PERFORMANCE LEVEL BARRIER 1
21.12.2018 standardbridgedrawings@rms.nsw.gov.au
EDMS No
STANDARD SHAPES
STANDARD DRAWING No

DATE
DS2018/001771
A1 B0505
COPYRIGHT ROADS AND MARITIME SERVICES 2018