You are on page 1of 2

CRANE AND HEAVY EQUIPMENT CERTIFICATION Report No.

CCR-2024-0172
REPORT OF EXAMINATION OF CRANE OR OTHER LIFTING APPLIANCE
Page 1 of 2
SW7 West Area, South Tower, Park Central Towers, 8735 Makati Ave., Makati City, PH
Location of Lifting Appliance
Name and Address of Owner FOKUSI CONSTRUCTION INC., UNIT 2105 & 2106, HIGH STREET SOUTH
CORPORATE PLAZA TOWER 1, 26TH ST. COR. 11TH AVE., BGC, TAGUIG CITY
Description and distinctive number of Motorized Gondola, model ZLP 630, serial #212839 with 2 motors, cradle 400 cm Long
Lifting Appliance motors/safety locks type YEJ 90L-4, sn #WRO 14405/#HM 1994 & #200146/#200147
Motive Power 440 volts, 3-phase, 60 Hz, 1.5 kW, 3.2 A eqpt. ID: GB2
Date of Construction 2020 - 04
The history should be briefly given and the
examiner should state whether he has seen
the last previous report.
January 25, 2021 (report no. CCR-2021-0268), 400 kg.
Date of last tests and test load applied
1. (a) What examination and tests were
applied ? THOROUGH VISUAL, FUNCTION AND LOAD TEST
(b) Are limiting or overwinding
protection devices satisfactory ?
SATISFACTORY
(c) Are S.W.L. clearly marked ? SATISFACTORY
(d) Type of S.W.L. indicator and is it in ---
good order ?
2. CONDITION AS FOUND (structure, ropes, drums, gear pulleys, shafts, pins, back balance, clutches, brakes, travel wheels, tracks, axles, chassis,
undercarriage foundation slewing, track rollers, limit switches, trips, end stops, chains, rope or chain attachments ratchet wheels, pawls, springs, jacks
and frames, rail clips, hooks)
AS NOTED
3. Repairs if any required and period
within which they should be executed
and any other conditions which the
person making the examination thinks None
is necessary to specify for securing
safe working.
4. Maximum SAFE WORKING LOAD
subject to repair, renewal, alteration if
any as specified in 3 above. (For jib 350 kilograms
cranes see overleaf.)
5. Other observations (continue overleaf)

I certify that on January 15, 2024 I thoroughly examined the lifting appliance described above and that this is a true report of
the result. The equipment described above was found to be in satisfactory operating condition. The lifting appliance should
be presented for thorough examination on or before July 14, 2024.
Issued To FOKUSI CONSTRUCTION INC.

Engr. Emerson M. Tera James F. Porter, Jr.


P.M.E. 3770 / PTR No. 8791048 General Manager
The organization has no liability for loss or damage caused by its organs, officers, employees, or others who act under assignment from the organization,
regardless of whether such person has acted intentionally or negligently and irrespective of whether the loss or damage has affected the company or
others who have requested the organization’s assistance or any third party who without any contractual relations with the organization, has acted or made
arrangements in reliance on decisions made or information given by or on behalf of the organization.

Nor in cases as mentioned in the preceding paragraph, can the individual or individuals who have personally caused the loss or damage be held liable.

Accredited Testing Organization - DOLE-BWC Accreditation No. 1410-21022421-0015


8263 Constancia St., Bgy. Olympia, Makati City, Tel. (+63) 8899 0321 Mobile 0917 507 7187
CRANE AND HEAVY EQUIPMENT CERTIFICATION Report No. CCR-2024-0172
REPORT OF EXAMINATION OF CRANE OR OTHER LIFTING APPLIANCE
Page 2 of 2

LOAD TESTING / OPERATIONAL TEST REPORT


Motorized Gondola, model ZLP 630, serial #212839 with 2 motors, cradle 400 cm Long
EQUIPMENT motors/safety locks type YEJ 90L-4, sn #WRO 14405/#HM 1994 & #200146/#200147
AS PER EQUIPMENT DETAILS ACTUAL TEST / NOTES
Fixture / Location SW7 West Area, South Tower, Park Central operates from level 4 to level 67
Towers, 8735 Makati Ave., Makati City, PH
Supports / Anchorage 2 sets of steel tubular beam each 5.98 meters Long SATISFACTORY
Cradle / Carriage 400 cm L x 69 cm W x 110 cm H SATISFACTORY
Electric Motor (A) type YEJ 90L-4, serial #WRO 14405, date 2020-9 440 volts, 3-phase, 60 Hz, 1.5 kW, 3.2 A
Electric Motor (B) type YEJ 90L-4, serial #HM 1994, date 22.07.08 440 volts, 3-phase, 60 Hz, 1.5 kW, 3.2 A
Speed (Travel Quality) 9.3 ±0.5 Meter per Minute SATISFACTORY
Hoist Line (A) two (2) independent lines each @ 8.3 mm dia. type LTD 630, serial #223215, date 2020-1
Hoist Line (B) two (2) independent lines each @ 8.3 mm dia. type LTD 630, serial #223214, date 2022-4
Synchronized Switch Installed SATISFACTORY
Overload Device -- NONE INSTALLED
Upper Limit Device Installed SATISFACTORY
Emergency Stop Installed SATISFACTORY
Brakes (Normal) Installed SATISFACTORY
Anti-Tilting Device (A) Installed, type LS30, serial #200146 SATISFACTORY, mfg. date 2020-04
Anti-Tilting Device (B) Installed, type LS30, serial #200147 SATISFACTORY, mfg. date 2020-04
Counterweights 650 kg. + 650 kg. = 1,300 kg. SATISFACTORY
Load Capacity each motor rated 630 kilograms SATISFACTORY, load test @ 400 kg.

The equipment was inspected based on ASME A10.8 and equipment specifications. During the actual testing, the
motorized gondola was able to lift a test load of 400 kilograms and was found to be stable. The equipment was operated to
ascend and descends; then held suspended for fifteen (15) minutes. No slipping was observed. The motorized gondola was
found to be in satisfactory operating condition.

Note/Remark:

None

***************** Nothing Follows *****************

General Reminders:

• Conduct daily check of davit supports, wire ropes, motor-mounting and safety lifelines; keep record in logbook.
• Operators / users should be aware and knowledgeable of machine operation and safety mechanisms.
• Use rope grab or fall-arrest mechanism for each personnel safety lifeline.
• An auxiliary restraint rope may be installed on the gondola cradle/carriage as additional equipment safety line.
• When the anti-tilt device engages, a power cut-off device for the motor - if installed - will be advantageous.
• An overload warning or power shut-off device for the cradle - if installed - will be advantageous.
• Provide portable fire extinguisher during operation; ensure daily equipment check is conducted.

Accredited Testing Organization - DOLE-BWC Accreditation No. 1410-21022421-0015


8263 Constancia St., Bgy. Olympia, Makati City, Tel. (+63) 8899 0321 Mobile 0917 507 7187