You are on page 1of 7

EXPLOSION-PROOF

LUMINAIRES

Explosion-proof
Luminaires
Explosion-proof luminaire is indispensable for industrial lighting. It can be
flammable and combustible gas or dust environment like generator factory,
heavy industrial warehouse,papermaking factory, dock, platform, dockyard,
chemical plant, equipment processing factory, etc.
Explosion-proof luminaires for such area needs to meet the standard of UL
Class I Division 2, Class II Division 1; IEC60079: Zone 2, Zone 21 and 22.
How to determine if a luminaire is explosion proof ?
5 All explosion-proof luminaires must pass the relevant certifications and tests specified to hazardous locations
from official institutions or organizations, such as the UL, CSA, etc. In the USA, the explosion-proof luminaires
3 require a certification to UL 844 standard. The three main certifications for electrical equipment in hazardous
locations are NEC (North America), ATEX (Europe), and IECEx (Intentional).
2
6
1

1 3 5 7

Chemical Foundries Power Manufacturing


Generation

2 4 6

Oil, Gas, and Petrochemical Pulp and Paper Waste and sewage treatment

Explosion-proof
Luminaires
What are explosion-proof luminaires?
Explosion-proof luminaires are so-called hazardous location lights. In simple words, explosion-proof luminaires
are the lighting fixtures having a degree of capacity to isolate the fixtures from flammable substances and prevent-
ing ignition and sparks. explosion-proof luminaires are usually utilized in hazardous locations, which refer to areas
where a large amount of volatile or flammable gas, vapor, dust, or fiber is present in the air. explosion-proot
luminaires can prevent the ignition or sparks escaping from the robust housing.
How to choose the right explosion-proof luminaires Selection guide
for hazardous areas ? 5 Our explosion-proof luminaires use powerful LED technology, high quality materials, 5 durable construction,
and specialized designs to meet all lighting requirements for hazardous environments. They are ideal for
Knowing the classification of hazardous areas is the basic to choose the right explosion-proof luminaires for 3 hazardous locations that require efficient and powerful lighting. Featuring die cast aluminum shell and special
hazardous areas. Hazardous locations are divided by class/division and zone systems. outdoor powder our explosion-proof luminaires are resistant to corrosion. The rugged heat sinks and active
thermal management make them withstand the high temperature environment. Our LED explosion-proof
luminaires are available in various classes and divisions ratings. Each of these lighting fixtures can maximize
Class/division system their performance and reliability only in areas where they are best suited.Therefore, make sure yo u get the
Class/division right LED explosion -proof luminaires for your applications.
1 classification system is based on the type, condition, and nature of hazardous locations.

Class/ Division/ Group System


Class I 7 Model Hazardous Areas
gases, vapors or liquids
Croup Gas: Zone 1 & Zone 2.
Division
Dust: Zone 21 & Zone 22.
1 2 A B C D Class I, Divsion 1, Group B, C, D.
HA03 Class I, Divsion 2, Group B, C, D.
Continuous Hazardous zone Intermittent Hazard-Free Zone acetylene hydrogen gasses vapors ethylene gasoline propane alcohol Class II, Divsion 1, Group E, F, G.
Class II, F, G.
Class III.

Class Il
Gas: Zone 2.
dusts
Dust: Zone21 & Zone22
Division Croup Class I, Divsion 2, Group A, B, C, D.
HA04 Class II, Divsion 1, Group E, F, G.
1 2 E F G Class II, Divsion 2, Group F, G.
Class III.
Continuous Hazardous zone Intermittent Hazard-Free Zone metal dusts carbonaceous dusts non-conductive dusts

Gas: Zone 2.
Dust: Zone21 & Zone22
Class IIl
Class I, Divsion 2, Group A, B, C, D.
fibers or combustible flyings HA05
Class II, Divsion 1, Group E, F, G.
Division Class II, Divsion 2, Group F, G.
Class III.
1 2

Continuous Hazardous zone Intermittent Hazard-Free Zone


Gas: Zone2
Dust:Zone21 & Zone22
HA06 Class I, Divsion 2, Group A, B, C, D
Class II, Divsion 2, Group F, G
Class III

Zone system
Zone system directly divides the hazardous locations into 6 zones, three zones for gases and the rest for
1
dust substances.

Explosion-proof
Zone System

Luminaires
ATEX Zone
Zone Description
Gas Dust 7

0 20 A place where explosive atmosphere is present contentiously or for a long period.

1 21 A place where explosive atmosphere is likely to occur occasionally in normal operation.

2 22 A place where explosive atmosphere is likely to occur infrequently or for a short period.
HA04 Sparkle Features:
· Complete certifications ATEX, IECEx, CSA.
For Extreme Environments and Tough Conditions
· Gas: Zone 2.
Dust:Zone21&Zone22.
Sparkle is an LED flood light for hazardous locations. Due to hazardous environments, Sparkle is designed Class I, Div. 2, GR. A, B, C, D.
with safety and reliability at the forefront to meet and exceed customer expectations. Class II, Div. 1, GR. E, F, G.
Class II, Div. 2, GR. F, G.
A rugged heat sink, active thermal management, and international LED and driver brand enable this Iron Class III.
Man to endure high temperatures up to 65°C and low temperatures as -40°C. Equipped with stainless
· Marine grade.
steel hardware and DACROMET coating with multiple protective layers as well as well as a copper-free
body, all to ensure resistance to corrosion, harsh chemicals, and tough environments. · Warm white, cool white, and Colored LED R/G/B/Amber
optional.
The Sparkle is approved for use in UL844: Class I Division 2, Class II Division 1. IEC60079: Zone 2, Zone
21, and 22. · 12 optics for different applications.

The fixture is available in 150W, 200W, and 240W, with 12 different optical patterns, warm white-cool · Input Voltage: AC100-277V, AC277-480V, (50/60HZ).
white color, and colored LED: R/G/B/AMBER optional. With a high light efficiency of 150lm/w, you can
· Loop-in & loop-out connections.
choose this perfect fixture that suits corresponding hazardous areas.
· cable-entry:M25*1.5 or 3/4''NPT.

T1 25x60° T4 70x125°
t10° t55° 15° 30°

T2 45x155° T2 70x146°
60° 90° t50° t50°

T2 30x90° T3 30x140° T4 50x125°


T5 145°
t40° t50° t55°

IP66 IK08

Explosion-proof
Anti-

Luminaires
corrosion

Code Watt Efficacy(Ra70) Lumen(±5%) N.W/pc(kgs) Size(LxWxHmm)

HA04-150 150W 150lm/W 22,500lm 13 567x473x174


HA04-200 200W 150lm/W 30,000lm 13 567x473x174
HA04-240 240W 150lm/W 36,000lm 13 567x473x174

Disclaimer:
207 Technical data is subject to change without prior notice. Explosion-proof Luminaires 208
Features:
· Complete certifications ATEX, IECEx, CSA.

· Gas: Zone 1 & Zone 2.


Dust: Zone 21 & Zone 22.
Class I, Division 1, Groups B, C, D.
Class I, Division 2, Groups B, C, D.
Class II, Division 1, Groups E, F, G.
Class II, Division 2, Groups F, G.
Class III.

· Marine grade.

· 5 mounting options: Ceiling Mount, 25°Stanchion


Mount, Wall Bracket, Pendant Mount and Trunnion
Mount.

120°

· Input Voltage: AC120-277V, AC277-480V (50/60Hz).

· Warm white to cool white (2000K-6500K),optional colored


IP66 IK10
LED (R/G/B/AMBER).

· Loop-in & loop-out connections.


Anti-
· Cable-entry:M25*1.5, M20*1.5 or corrosion

3/4''NPT,1''NPT,1-1/2''NPT, 1-1/4''NPT.

HA03 Victory

Explosion-proof
For Extreme Environments and Tough Conditions

Luminaires
HA03 is designed to stand up to the demanding conditions faced in IEC60079 Zone 1,2、Zone 21
and 22 and UL844 standard Class I Division 1、Class II Division 1 environments. Rugged materials
and design to ensure resistance to extreme environments and tough conditions.
Code Watt Efficacy(Ra70) Lumen(±5%) N.W/pc(kgs) Size(LxWxHmm)

HA03-030 30W 140lm/W 4,200lm 8.3 320x320x335


HA03-040 40W 140lm/W 5,600lm 8.3 320x320x335
HA03-050 50W 140lm/W 7,000lm 8.3 320x320x335
HA03-060 60W 140lm/W 8,400lm 8.3 320x320x335
HA03-070 70W 140lm/W 9,800lm 8.3 320x320x335

Disclaimer:
209 Technical data is subject to change without prior notice. Explosion-proof Luminaires 210
HA05 Conqueror Features:
· Complete certifications ATEX, IECEx, CSA.
For Extreme Environments and Tough Conditions
· Gas: Zone 2.
Dust:Zone21&Zone22
With its superior waterproof, dustproof, anti-corrosion and anti-vibration properties, HA05 series Class I, Div. 2, GR. A, B, C, D.
provides ideal solution for lighting in various harsh and hazardous locations. Adopt high-strength Class II, Div. 1, GR. E, F, G.
Class II, Div. 2, GR. F, G.
copper-free aluminum alloy die-casting shell, surface spraying special outdoor powder, exposed fixed
Class III.
parts and brackets are made of stainless steel + special anti-corrosion treatment, suitable for marine
· Marine grade.
environment, corrosion-resistant for more than 10 years.
· 30-240W available.
Provides 90 minutes of emergency lighting to help keep people safe and plant running smoothly.
· 6 mounting options:Ceiling mount, Pendant mount,
Wall bracket, 25° Stanchion mount, 90° Stanchion
mount, Trunnion mount.

T1 T3 62x144° T5
96x144° t45° 140°

· Input Voltage: AC100-277V,AC277-480V (50/60Hz).

· Provide 90 minutes or 3 hours emergency lighting in IP66 IK08

case of power failure.

· Warm white to cool white (2000K-6500K),optional


Anti-
colored LED (R/G/B/AMBER). corrosion

· Loop-in & loop-out connections.


· Cable-entry:M25*1.5, M20*1.5 or 3/4''NPT, 1''NPT,
1-1/2''NPT, 1-1/4''NPT.

Explosion-proof
Code Watt Efficacy(Ra70) Lumen(±5%) N.W/pc(kgs) Size(DxHmm)

Luminaires
HA05-030 30W 140lm/W 4,200lm 6.5 Ø300x186
HA05-050 50W 140lm/W 7,000lm 6.5 Ø300x186
HA05-075 75W 140lm/W 10,500lm 6.5 Ø300x186
HA05-100 100W 140lm/W 14,000lm 6.5 Ø300x186
HA05-120 120W 140lm/W 16,800lm 9.7 Ø380x201
HA05-150 150W 140lm/W 21,000lm 9.7 Ø380x201
HA05-180 180W 140lm/W 25,200lm 9.7 Ø380x201
HA05-200 200W 140lm/W 28,000lm 9.7 Ø380x201
HA05-240 240W 140lm/W 33,600lm 9.7 Ø380x201

Disclaimer:
211 Technical data is subject to change without prior notice. Explosion-proof Luminaires 212
HA06 Supernova
Features:
· Complete certifications ATEX, IECEx,CSA.
For Extreme Environments and Tough Conditions · Gas: Zone2.
Dust:Zone21 & Zone22.
Class I, Div.2, Groups A, B, C, D.
Designed as a cost-effective linear explosion-proof lamp for Zone 2, Zone 21/22, and C1 D2
Class II, Div. 2, Groups F, G.
C2 D2 hazardous, marine, and wet locations, Supernova features an IK08 high-strength Class III.
fiberglass-reinforced polycarbonate housing and UV-resistant polycarbonate diffuser,
· Marine grade.
making it an ideal solution for projects on a tight budget. Moreover, Supernova offers
AC/DC input options for a wider application range. · High system efficiency up to 160lm/w.

· 5 mounting options: ceiling mount, trunnion mount,


hoop mount, loop mount, pendant mount.

T1 25x60° T4 70x125°
t10° t55° 15° 30°

T2 45x155° T2 70x146°
60° 90° t50° t50°

· Warm white to cool white (2000K-6500K),optional


T2 30x90° T3 30x140° T4 50x125°
colored LED (R/G/B/AMBER). t40° t50°
T5 145°
t55°

· Loop-in & loop-out connections.


· Cable-entry:M25*1.5, M20*1.5,M32*1.5 or 120° 90°
3/4''NPT,1''NPT, 1/2'' NPT.
· 120-277Vac/277-480Vac or 24-48Vac/18-48Vdc optional.

· 90 minutes or 3 hours emergency battery backup optional. IP66 IK08

Anti-
corrosion

Explosion-proof
Luminaires
Code Watt Efficacy(Ra70) Lumen(±10%) N.W/pc(kgs) Size(DxHmm)

HA06-030 30W 160lm/W 4,800lm 3.4 Ø618x150x202


HA06-040 40W 160lm/W 6,400lm 3.4 Ø618x150x202
HA06-050 50W 160lm/W 8,000lm 3.4 Ø618x150x202
HA06-060 60W 160lm/W 9,600lm 5.0 Ø1232x150x202
HA06-070 70W 160lm/W 11,200lm 5.0 Ø1232x150x202
HA06-080 80W 160lm/W 12,800lm 5.0 Ø1232x150x202
HA06-100 100W 160lm/W 16,000lm 5.0 Ø1232x150x202

Disclaimer:
213 Technical data is subject to change without prior notice. Explosion-proof Luminaires 214

You might also like