SCHEDULE OF BEAM

DESIGNATION BEAM SIZE NUMBER OF BARS SPACING 0F 10MM ø STIRRUPS

AT SUPPORT AT MIDSPAN

FOOTING TIE BEAM

FTB1 250mmx300mm o o o 3pcs-16mm ø o o 2pcs-16mm ø 5pcs-50mm, 5pcs-75mm


5pcs-100mm
o o 2pcs-16mm ø o oo 3pcs-16mm ø rest @ 150mm

FTB2 250mmx300mm o o o o 4pcs-16mm ø o o 2pcs-16mm ø 5pcs-50mm, 5pcs-75mm


5pcs-100mm
o o 2pcs-16mm ø oo o o 4pcs-16mm ø rest @ 150mm

ROOF BEAM

RB1 250mmx300mm o o o 3pcs-16mm ø o o 2pcs-16mm ø 5pcs-50mm, 5pcs-75mm


5pcs-100mm
o o 2pcs-16mm ø o oo 3pcs-16mm ø rest @ 150mm

RB2 250mmx300mm o o o 3pcs-16mm ø o o o 3pcs-16mm ø 5pcs-50mm, 5pcs-75mm


5pcs-100mm
o oo 3pcs-16mm ø o oo 3pcs-16mm ø rest @ 150mm

RB3 250mmx300mm o o o o 4pcs-16mm ø o o 2pcs-16mm ø 5pcs-50mm, 5pcs-75mm


5pcs-100mm
o o 2pcs-16mm ø oo o o 4pcs-16mm ø rest @ 150mm