0% found this document useful (0 votes)
4K views1 page

Roof Beam Reinforcement Details

The document provides specifications and details for roof beams and main beams including reinforcement requirements. It specifies that splices cannot be made within 2H of supports, bottom bars must be spliced between L4 and 2H from supports, and top bars can be spliced beyond 2H from supports. It also requires hoops within 2H of supports and hoops less than D4 and 100mm within spliced regions. Finally, it includes a schedule with dimensions, reinforcement sizes and bar spacing for two beams: B-1 and B-2.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4K views1 page

Roof Beam Reinforcement Details

The document provides specifications and details for roof beams and main beams including reinforcement requirements. It specifies that splices cannot be made within 2H of supports, bottom bars must be spliced between L4 and 2H from supports, and top bars can be spliced beyond 2H from supports. It also requires hoops within 2H of supports and hoops less than D4 and 100mm within spliced regions. Finally, it includes a schedule with dimensions, reinforcement sizes and bar spacing for two beams: B-1 and B-2.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

L

2H L-4H 2H

3-10mm diameter stirrups


3-10mm diameter stirrups 20mm diameter continous rebar 3-10mm diameter stirrups
300mm Ld spaced @ 50 mm spaced @ 50 mm
spaced @ 50 mm
bend @ 90 degrees

8-10mm spaced stirrups


@ 100mm 20mm diameter 8-10mm spaced stirrups @ 100mm
continuous rebar
8-10mm spaced stirrups @ 100mm
10mm diameter stirrups @ 200mm
50mm concrete cover

4-16mm diameter rebar


250 mm

300 mm

ROOF BEAM (B2)

2H L-4H 2H

3-10mm diameter stirrups 20mm diameter continous rebar 3-10mm diameter stirrups
3-10mm diameter stirrups spaced @ 50 mm
300mm Ld spaced @ 50 mm spaced @ 50 mm
bend @ 90 degrees

8-10mm spaced stirrups 8-10mm spaced stirrups @ 100mm


@ 100mm 20mm diameter
continous rebar
10mm diam stirrups @ 200mm 8-10mm spaced stirrups @100mm

50mm concrete cover

4-20mm diameter rebar


300 mm

400 mm

2-20mm diameter rebar

MAIN BEAM (B1)

NSCP SPECIFICATIONS:
1. NO SPLICE SHALL BE MADE AT DISTANCE 2H FROM FACE OF THE SUPPORT
2. BOTTOM BARS SHALL BE SPLICED WITHIN L4 BUT NOT LESS THAN 2H FROM FACE OF THE SUPPORT
3. TOP BARS CAN BE SPLICED ANYWHERE BEYOND 2H FROM THE FACE OF THE SUPPORT.
4. HOOPS SHALL BE USED WITHIN THE DISTANCE 2H FROM FACE OF THE SUPPORT.
5. HOOPS LESSER THAN (D4 AND 100MM) SHALL BE USED WITHIN THE SPLICED LENGTH.
6. STIRRUPS WITH SEISMIC HOOK CAN BE USED BEYOND 2H.

S C H E D U L E O F R O O F B E A M S/M A I N B E A M S

WIDTH DEPTH
N U M B E R-S I Z E
MARK b d
O F R E B A R S SPACING OF STIRRUPS REMARK/S

(mm) (mm) CONT. TOP CONT. BOTTOM


STIRRUPS
BARS BARS

3 @ 50MM, 8 @100MM,REST 200MM O.C


B-1 300 400 4-20MM DIA. 2-20MM DIA. 10MM DIA.

3 @ 50MM, 8 @100MM, REST 200MM O.C


B-2 250 300 2-16MM DIA. 2-16MM DIA. 10MM DIA.

You might also like