Professional Documents
Culture Documents
2H L-4H 2H
300 mm
2H L-4H 2H
3-10mm diameter stirrups 20mm diameter continous rebar 3-10mm diameter stirrups
3-10mm diameter stirrups spaced @ 50 mm
300mm Ld spaced @ 50 mm spaced @ 50 mm
bend @ 90 degrees
400 mm
NSCP SPECIFICATIONS:
1. NO SPLICE SHALL BE MADE AT DISTANCE 2H FROM FACE OF THE SUPPORT
2. BOTTOM BARS SHALL BE SPLICED WITHIN L4 BUT NOT LESS THAN 2H FROM FACE OF THE SUPPORT
3. TOP BARS CAN BE SPLICED ANYWHERE BEYOND 2H FROM THE FACE OF THE SUPPORT.
4. HOOPS SHALL BE USED WITHIN THE DISTANCE 2H FROM FACE OF THE SUPPORT.
5. HOOPS LESSER THAN (D4 AND 100MM) SHALL BE USED WITHIN THE SPLICED LENGTH.
6. STIRRUPS WITH SEISMIC HOOK CAN BE USED BEYOND 2H.
S C H E D U L E O F R O O F B E A M S/M A I N B E A M S
WIDTH DEPTH
N U M B E R-S I Z E
MARK b d
O F R E B A R S SPACING OF STIRRUPS REMARK/S