You are on page 1of 6
ESHER EMR A LHe Guideline for Periodic Inspection, Testing and Certification (PITC) Work CL we RD) Fs) REMEM Ril MSALBAR FRHEMAOOR AY EBEALIE Low voltage electrical ‘work not exceeding ARS 400A BEALE Low voltage electrical ‘work of any capacity FRR 250030H0 BEALE Low voltage electrical ‘work not exceeding 25004 REPS tee Arrange power suspension *notes. wane | @) Fe Tica EMRE RUE 1 RRBRALRARMBARS BR DER AR DRED NORDRR ERSS LASERS ARETE BNL ROME HAZE « 2 R201 2A ARTE ee PRE AS Se NS «PPE APA EN EZ LAR se = 3 dhs PRAHA SAANMASTRCRARER EMO AUS Ra WRAAMRE - REVRAMRAMTRADRHAE HETAAME ERA PERE BRM » LOREAL HAR Ee ERE ° *Notes : Power Suspension Arrangement fer PITC Work 1 In order to ensure personal safety of the electrical workers and avoid affecting building power supply in case of electrical accident, the power company's electricity supply shall be cut off in carrying out PITC work on main switchboard that is connected to power company’s transformer. 2. For WR2 submission Involving the above-mentioned main switchboard on or after 1 December 2011, the power company’s record for temporary disconnection of electricity supply shall also be submitted for EMSD's vetting. 3 Furthermore, as the temperary disconnection of power company's electricity supply will affect the building users for a short period of time, the Registered Electrical Contractor shall also closely collaborate with the building owners, Incorporated ‘Owners and properiy management companies to work out the power suspension ‘arrangement and temporary measures that meet the building operational needs with the aim to minimizing disturbance to the building users resulting from the PITC work. EMRASARE PITC Work for Distribution Circuit ‘sual inspection 32 AeLMRiCIE AS Continuity test for protectve conductors 38 AUER MIMO AREA, Continuity teat for ring final luctors Soul cond 34 SmRRa } Insdation resstance test tt ~ 35 SHER Polarity test: 36 Sem RES Earth elactode reistanca est 37 SEA Earth fault loop impedance test (| 22 Ramen Functonal est for protective vices CULCCECCEL PITC Work for Low Voltage Switchboard 44 42 43. 44 45 46 AZ 48 VkEwe fame Isolation and proved dead aR Cleaning BRE Visual inspection STARS ‘Contact resistance test Be Saws Insulation resistance test RROLAAR Secondary injection test PRR E HEAT BE Functional test for protective devices RRR ET Check indication devices suet ila ae Record all inspection and testing results. aahS Resume power Re Ae BAB Al ace Issue periodic test certificate and testing records MERARE wAiMstieRR Ba eee Testing Record Checklist Schematic diagram EREPAAE AS RAAT eS Les Submit periodic test certificate and testing records for EMSD's endorsement S040) wetes Beamon Electricity Legislation Division Electrical and Mechanical Services Department 3 Kai Shing Steet, Kowtoon, Hong Kong FES Tal 1829 (BH Fax: (852) 2995 4929 BRE Website: wan emad gok hc FE Ernallinfo@emsd.gouhk

You might also like