Job Name: Truss ID: F4 Qty: 1 SPACING: 1- 0- 0 PLY: 1 WEIGHT: 128.

93
TC FORCE AXL BND CSI ID SCRWS
1-2 0 0.00 0.25 0.25 1 -SP
2-3 -478 0.07 0.26 0.43 1 SP-
3-4 -478 0.07 0.26 0.32 1 -SP
4-5 -1326 0.19 0.23 0.40 1 SP-
5-6 -2029 0.28 0.19 0.45 1
6-7 -2706 0.38 0.19 0.54 1
7-8 -3284 0.46 0.16 0.61 1
8-9 -3848 0.54 0.15 0.67 1
9-10 -4315 0.60 0.15 0.75 1
10-11 -4766 0.67 0.13 0.78 1
11-12 -5119 0.72 0.14 0.85 1
12-13 -5456 0.76 0.11 0.86 1
13-14 -5697 0.80 0.13 0.92 1
14-15 -5920 0.83 0.08 0.90 1
15-16 -6047 0.85 0.12 0.97 1
16-17 -6156 0.86 0.05 0.91 1
17-18 -6169 0.86 0.12 0.99 1
18-19 -6166 0.86 0.05 0.91 1
19-20 -6066 0.85 0.12 0.97 1
20-21 -5949 0.83 0.08 0.90 1
21-22 -5735 0.80 0.13 0.93 1
22-23 -5504 0.77 0.11 0.86 1
23-24 -5177 0.73 0.14 0.86 1
24-25 -4833 0.68 0.13 0.79 1
25-26 -4393 0.62 0.15 0.76 1
26-27 -3935 0.55 0.15 0.68 1
27-28 -3381 0.47 0.16 0.62 1
28-29 -2813 0.39 0.19 0.55 1
29-30 -2145 0.30 0.19 0.47 1
30-31 -1443 0.20 0.22 0.41 1 -SP
31-32 -757 0.11 0.23 0.32 1 SP-
32-33 -757 0.11 0.23 0.38 1 -SP
33-34 0 0.00 0.22 0.22 1 SP-
0-9-0
BC FORCE AXL BND CSI ID SCRWS 0-9-0
35-36 0 0.00 0.08 0.08 1 -SP
36-37 477 0.06 0.23 0.29 1 SP-
37-38 477 0.06 0.26 0.42 1 -SP 1 3 4 6 8 10 12 14 16 18 20 22 24 26 28 30 3234
38-39 1325 0.17 0.26 0.42 1 SP- 2 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33
39-40 2028 0.26 0.20 0.45 1
40-41 2706 0.35 0.20 0.54 1
41-42 3284 0.42 0.20 0.61 1 X X X
42-43 3847 0.49 0.20 0.68 1
43-44 4315 0.55 0.18 0.72 1 1-5-15 1-5-15
44-45 4765 0.61 0.19 0.78 1
45-46 5119 0.66 0.16 0.81 1 X X X
46-47 5456 0.70 0.17 0.85 1
47-48 5696 0.73 0.13 0.86 1
48-49 5920 0.76 0.15 0.89 1
49-50 6046 0.78 0.11 0.88 1
50-51 6156 0.79 0.13 0.89 1
51-52 6169 0.79 0.08 0.87 1
52-53 6165 0.79 0.13 0.89 1 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 6668
53-54 6065 0.78 0.11 0.88 1 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67
54-55 5948 0.76 0.15 0.89 1 0-3-4
55-56 5735 0.74 0.13 0.86 1
56-57 5504 0.71 0.17 0.86 1 0-3-4
57-58 5177 0.66 0.16 0.81 1
58-59 4833 0.62 0.19 0.79 1
59-60 4392 0.56 0.18 0.73 1
60-61 3934 0.50 0.20 0.69 1
61-62 3381 0.43 0.20 0.62 1
62-63 2813 0.36 0.20 0.55 1
63-64 2145 0.27 0.20 0.47 1
64-65 1443 0.19 0.27 0.44 1 -SP
65-66 757 0.10 0.27 0.42 1 SP-
66-67 757 0.10 0.22 0.32 1 -SP
Scale: 1/8" = 1'

WARNING Read all notes on this sheet and verify all design parameters. Designer:
Dsgn Chk:
WO: Motor Enclave Way Unit - 207 - (REV 02
Truss design on this sheet is only valid with NUTRUSS sections and is for an individual building component, not a truss system. Bracing

NUTRUSS
TM shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing which is part of the building design and Engg Chk:
which must be considered by the building designer. Bracing shown is lateral bracing of truss members only. Any additional bracing, Cutting :
temporary and/or permanent, is the responsibility of the truss erector and/or the building designer. The Professional Engineer’s seal TC Live 40.00 psf Design Spec: AISI S100-2012
A NUCONSTEEL Product indicates only that the truss assembly shown on this sheet meets the acceptable design criteria for the loads, loading condition, truss
configuration and spans specified. TC Dead 15.00 psf Buildg Spec: IBC-2018
BC Live 0.00 psf
BC Dead 5.00 psf
Date: 1/25/2024 @ 16:21:16
TOTAL 60.00 psf Seqn S8.1.0a - 390
Job Name: Truss ID: F4 Qty: 1 SPACING: 1- 0- 0 PLY: 1 WEIGHT: 128.93
67-68 0 0.00 0.03 0.03 1 SP- Type ID SECTION Fy(ksi) Joints NOTE:MAXIMIMUM TRUSS SPACING IS 12.0 " O.C. This design based on chord bracing applied
TC 1 20TC18 50 THIS DESIGN IS THE COMPOSITE RESULT OF per the following schedule:
WEB FORCE CSI ID SCRWS BC 1 20TC18 50 MULTIPLE LOAD CASES. max o.c. from to
1-35 119 0.02 1 WEB 1 20TC18 50 Loaded for 10 PSF non-concurrent BCLL. BC 24.00" 0- 0- 0 33- 8-10
2-36 -1409 0.26 1 SP-SP Drainage must be provided to avoid ponding. Loaded for 200 lb non-concurrent moving TC 12.00" 0- 0- 0 33- 8-10
3-37 1307 0.17 1 Galvanization: G60 BCLL.
4-38 -1465 0.31 1 SP-SP 20 psf bottom chord live load NOT required REACTIONS
5-39 1215 0.16 1 on this truss, per IBC/IRC requirements for BRG X-LOC SIZE REACT HORIZ
6-40 -1170 0.25 1 attics with limited storage. 1 0- 1-12 3.50" 1014 1
7-41 999 0.13 1 2 33- 6-14 3.50" 1013 0
8-42 -973 0.21 1
9-43 808 0.10 1
10-44 -778 0.16 1
11-45 611 0.08 1
12-46 -582 0.12 1
13-47 416 0.05 1
14-48 -386 0.08 1
15-49 248 0.03 1
16-50 -222 0.05 1
17-51 162 0.03 1
18-52 153 0.03 1
19-53 -209 0.04 1 DEFLECTION LOC. ALLOW. LC
20-54 237 0.03 1 Vert TL: -1.50" (L/265) 17-18 L/240 1
21-55 -370 0.08 1 Vert LL: -1.00" (L/398) 17-18 L/360 1
22-56 398 0.05 1 Horz TL: 0.18"
23-57 -565 0.12 1
24-58 594 0.08 1 ===== Joint Locations =====
25-59 -762 0.16 1 1 0- 0- 0 35 0- 0- 0
26-60 791 0.10 1 2 0- 9- 0 36 0- 3- 4
27-61 -956 0.20 1 3 0-11- 4 37 0-11- 4
28-62 982 0.13 1 4 2- 0-13 38 1- 1- 8
29-63 -1155 0.24 1 5 2- 3- 0 39 3- 2- 5
30-64 1212 0.16 1 6 4- 3-12 40 3- 4- 7
31-65 -1387 0.27 1 SP-SP 7 4- 5-15 41 5- 5- 4
32-66 1215 0.16 1 8 6- 6-12 42 5- 7- 7
33-67 -1387 0.28 1 SP-SP 9 6- 8-15 43 7- 8- 4
34-68 52 0.01 1 10 8- 9-12 44 7-10- 7
11 8-11-14 45 9-11- 3
12 11- 0-11 46 10- 1- 6
13 11- 2-14 47 12- 2- 3
14 13- 3-11 48 12- 4- 6
15 13- 5-14 49 14- 5- 3
16 15- 6-10 50 14- 7- 5
17 15- 8-13 51 16- 8- 2
18 17- 9-10 52 16-10- 5
19 17-11-13 53 18-11- 2
20 20- 0-10 54 19- 1- 5
21 20- 2-12 55 21- 2- 1
22 22- 3- 9 56 21- 4- 4
23 22- 5-12 57 23- 5- 1
24 24- 6- 9 58 23- 7- 4
25 24- 8-12 59 25- 8- 1
26 26- 9- 8 60 25-10- 3
27 26-11-11 61 27-11- 0
28 29- 0- 8 62 28- 1- 3
29 29- 2-11 63 30- 2- 0
30 31- 3- 8 64 30- 4- 3
31 31- 5-10 65 32- 2-12
32 32- 4-15 66 32- 4-15
33 32- 7- 2 67 33- 5- 8
34 33- 8-10 68 33- 8-10
== X-Brac. Locations (Joints)==
BC TC
45 12
54 19
63 29
Each connection requires 3/8" diameter proprietary bolt supplied by NUCONSTEEL
SCRWS = The required number of double-sided #14 screws at each end of the truss member: SP = Spacer supplied by NUCONSTEEL
This truss has no Pre-Camber

WARNING Read all notes on this sheet and verify all design parameters. WO: Motor Enclave Way Unit - 207 - (REV 02
Truss design on this sheet is only valid with NUTRUSS sections and is for an individual building component, not a truss system. Bracing Chk:

NUTRUSS
TM shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing which is part of the building design and
which must be considered by the building designer. Bracing shown is lateral bracing of truss members only. Any additional bracing, Dsgnr:
temporary and/or permanent, is the responsibility of the truss erector and/or the building designer. The Professional Engineer’s seal TC Live 40.00 psf Design Spec: AISI-2001
A NUCONSTEEL Product indicates only that the truss assembly shown on this sheet meets the acceptable design criteria for the loads, loading condition, truss
configuration and spans specified. TC Dead 15.00 psf Buildg Spec: IBC-2018
When the specified screw count cannot be achieved at the chord to web connections, a 16 gauge gusset plate must be BC Live 0.00 psf
added on both sides of the connection. Typically, gusset plates are at pitch break joints.” BC Dead 5.00 psf
Min. screw spacing = 9/16" and min. edge distance = 9/16". Date: 1/25/2024 @ 16:21:16