Professional Documents
Culture Documents
Name of Work: UPGRADATION OF CONFERENCE ROOM AND REFURBISHING OF PLANETARIUM CORRIDOR AT DSCT
Name of the
Bidder/ Bidding
Firm / Company :
PRICE SCHEDULE
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be re
allowed to enter the Bidder Name and Values only )
1 2 4 5 6 7
1 UPGRADATION OF CONFERENCE ROOM
1.01 75.00 Sqm 1,200.00 #VALUE!
Providing and fixing 15 mm thick USG- Radar
Mineral Fibre False Ceiling tiles or equivalent of
size 600x600 mm in true horizontal level
suspended on inter locking metal grid of hot dipped
galvanised steel sections (galvanised @170
gsm/sqm.) consisting of main" T"
1.01
runner suitably spaced at joints to get required
length and of size 24x38 mm made from 0.30 mm
thick (minimum) sheet spaced at 1200 mm centre
to centre and cross "T " of size 24x25 mm made of
0.30 mm thick ( minimum) sheet,1200 mm long
spaced between main "T" at 600 mm centre to
centre to form a grid of 1200x600 mm and
1.01
secondary cross "T" of length 600 mm and size
24x25 mm made of 0.30 mm thick ( minimum)
sheet to be interlocked at middle of the 1200x600
mm panel to form grid of 600x600 mm and laying
15 mm thick mineral fibre false ceiling tiles of
approved texture in the grid including, wherever
required, cutting/ making, openings for services
like diffusers, grills, light fittings, fixtures, smoke
detectors etc. Main "T" runners to be suspended
from ceiling using
1.01
G.I slotted cleats fixed to ceiling with 6 mm dia.
and 50 mm long dash fasteners,4 mm G.I
adjustable rods with galvanised level clips spaced
at 1200 mm centre to centre along main T,bottom
exposed width of 24 mm of all T-sections shall be
prepainted with polyster paint,all complete at all
heights as per specifications drawings and as
directed by Engineer -in -Charge.AS/DWG
(Horizontal and vertical to be measured)
1.01
Note: i)
Only mineral Fiber ceiling area will be measured
for payment.
Ii) The mineral fibre ceiling shall either be precast
(moulded) or wetted product and shall have NRC
value of 0.5 ( minimum) CAC 35-39,Light
reflections 84% ( minimum),fire rating class A as
per ASTM E-84,suitable for 95% relate humidity
and also having Thermal resistance "(R)"=0.33 m2
deg.C/W
III) The job to be carried out by reputed company
like Lioyds Insulations (India) Ltd. / Armstrong or
equivalent having sufficient work experience
1.02
1.04 Providing and fixing M.S. grill round or square 125.00 Kg 61.80 #VALUE!
bars with M.S. flats at required spacing.
1.05 Dismantling tile work in floors and roofs laid in 75.00 Sqm 31.55 #VALUE!
cement mortar including stacking material within
50 metres lead: For thickness of tiles 10 mm to 25
mm
1.06 75.00 Sqm 362.60 #VALUE!
CC flooring 1:2:4 40mm tk. With 20mm nominal
size stone aggregate with a floating coat of lead
cement including cement slurry but excluding cost
of nosing of steps etc.., complete.
1.11 Extra for using veneered particle board conforming 8.00 Rm 33.45 #VALUE!
to IS 3097 Grade I, in item of pelmet 18mm thick
150mm wide with Non decorative veneer on both
sides
1.12 Providing and fixing teak wood lipping of size 8.00 Rm 41.10 #VALUE!
25x3 mm in pelmet
2 REFURBISHING OF PLANETARIUM
CORRIDOR
2.01 Wall painting with plastic emulsion paint of 120.00 Sqm 55.25 #VALUE!
approved brand and manufacture to give an even
shade: One or more coats on old work
2.02 Dismantling tile work in floors and roofs laid in 70.00 Sqm 31.55 #VALUE!
cement mortar including stacking material within
50 metres lead: For thickness of tiles 10 mm to 25
mm
2.03 7.00 Cum 4,478.15 #VALUE!
Providing and laying in position cement concrete
of specified grade excluding the cost of centering
and shuttering - All work up to plinth level : 1:4:8
(1 Cement : 4 coarse sand (zone-III) : 8 graded
stone aggregate 40 mm nominal size)
TEXT #
TOTAL AMOUNT
In Words
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
ALUE!
Please Enable Macros to View BoQ information
Q information