You are on page 1of 2

1

GENERAL NOTES
YARD CONNECTION ERF CONNECTION HORIZONTAL DRILLING ERF CONNECTION YARD CONNECTION
1. THE NEW CUSTOMER MANAGER AT THE JOHANNESBURG
WATER (PTY) LTD REGIONAL OFFICE MUST BE NOTIFIED
BEFORE ANY CONSTRUCTION WORKS RELATED TO THE
x x x x x x INSTALLATION OF WATER OR SEWER MAY BE COMMENCED.
x x x x x x
2. ALL CONSTRUCTION WORK SHALL COMPLY WITH THE
RELEVANT SABS 1200 SPECIFICATION AND JOHANNESBURG
WATER (PTY) LTD SPECIFIC REQUIREMENTS.

3. ALL MATERIALS USED IN INSTALLING WATER AND SEWER


x

x
MAINS SHALL COMPLY WITH THE RELEVANT SABS

x
x
SPECIFICATION AND WITH THE MINIMUM REQUIREMENTS
OF JOHANNESBURG WATER (PTY) LTD.

4. THE POSITION AND DEPTH OF ALL EXISTING SERVICES ON

MAIN SUPPLY >= 110mm PVC


THE SITE AND OFF THE SITE WHERE AFFECTED BY THE
WORKS SHALL BE CONFIRMED PRIOR TO ANY
CONSTRUCTION WORK ON THE INSTALLATION OF WATER

ERF BOUNDARIE

ERF BOUNDARIE
OF SEWER MAINS BEING COMMENCED.
x

x
x
5. ONLY JOHANNESBURG WATER (PTY) LTD STAFF SHALL
BUILDING CARRY OUT TIE-IN CONNECTIONS TO EXISTING WATER
BUILDING
AND SEWER MANHOLES AND MAINS. NOTE THAT A MINIMUM
OF 2 WEEKS NOTICE SHALL BE GIVEN TO JOHANNESBURG
WATER (PTY) LTD STAFF TO ATTEND SITE INSPECTIONS,
MEETING AND ANY OTHER NECESSARY ON SITE LIAISON.

GENERAL NOTES

x
x

x
x
1. ALL MATERIAL AND WORKMANSHIP MUST COMPLY WITH THE
REQUIREMENTS OF THE LATEST RELEVANT SABS
REQUIREMENTS .
500 500
H G G H
F F 2. DO NOT SCALE FROM THIS DRAWINGS
25mmØ 25mmØ
3. ALL DIMENSIONS ARE IN MILLIMETERS

x
x

(UNLESS OTHERWISE STATED)

x
x
25mmØ 25mmØ 4. ALL DIMENSIONS MUST BE CHECKED AND APPROVED ON
K J J K

500
A SITE

5. THIS DRAWING MUST BE READ IN CONJUNCTION WITH THE


32mmx25mmØ 32mmx25mmØ STANDARD SPECIFICATION
32mmØ 32mmØ 32mmØ
x x x x x x D D
x x x x x x
6. THE POSITION AND DEPTH OF ALL EXISTING SERVICES ON
B THE SITE AND OFF THE SITE WHERE AFFECTED BY THE
C C C WORKS SHALL BE CONFIRMED PRIOR TO ANY

500
500 500 CONSTRUCTION WORK ON THE INSTALLATION OF WATER
K J J K OF SEWER MAINS BEING COMMENCED.
25mmØ 25mmØ
7. ONLY JOHANNESBURG WATER (PTY) LTD STAFF SHALL
x

x
x

x
CARRY OUT TIE-IN CONNECTIONS TO EXISTING WATER
25mmØ 25mmØ AND SEWER MANHOLES AND MAINS. NOTE THAT A MINIMUM
F F OF 2 WEEKS NOTICE SHALL BE GIVEN TO JOHANNESBURG
H G G H
WATER (PTY) LTD STAFF TO ATTEND SITE INSPECTIONS,
MEETING AND ANY OTHER NECESSARY ON SITE LIAISON.

GENERAL
DOUBLE ERF DOUBLE ERF 1. THE NEW CUSTOMER MANAGER AT THE JOHANNESBURG WATER (PTY)
LTD REGIONAL OFFICE MUST BE NOTIFIED BEFORE ANY CONSTRUCTION
CONNECTION
x

x
x

x
CONNECTION WORKS RELATED TO THE INSTALLATION OF WATER OR SEWER MAY BE
COMMENCE.
TYPE -1 TYPE -2 2. ALL CONSTRUCTION WORK SHALL COMPLY WITH THE RELEVANT SABS
1200 SPECIFICATION AND JOHANNESBURG WATER (PTY) LTD SPECIFIC

ROAD RESERVE
ERF BOUNDARIE

ERF BOUNDARIE
REQUIREMENTS

3. ALL MATERIALS USED IN INSTALLING WATER AND SEWER MAINS SHALL


COMPLY WITH THE RELEVANT SABS SPECIFICATION AND WITH THE
MINIMUM REQUIREMENTS OF JOHANNESBURG WATER (PTY) LTD
BUILDING
BUILDING 4. THE POSITION AND DEPTH OF ALL EXISTING SERVICES ON THE SITE AND
x

x
x

x
OFF THE SITE WHERE AFFECTED BY THE WORKS SHALL BE CONFIRMED
PRIOR TO ANY CONSTRUCTION WORK ON THE INSTALLATION OF WATER
OF SEWER MAINS BEING COMMENCED.

5. ONLY JOHANNESBURG WATER (PTY) LTD STAFF SHALL CARRY OUT TIE-IN
CONNECTIONS TO EXISTING WATER AND SEWER MANHOLES AND MAINS.
NOTE THAT A MINIMUM OF 2 WEEKS NOTICE SHALL BE GIVEN TO
JOHANNESBURG WATER (PTY) LTD STAFF TO ATTEND SITE INSPECTIONS,
MEETING AND ANY OTHER NECESSARY ON SITE LIAISON

6. ALL DIMENSIONS ARE IN MILLIMETERS.(UNLESS OTHERWISE


SPECIFIED).
x

x
x

x
7. DO NOT SCALE FROM THESE DRAWINGS.

8. ALL CONSULTANT REMAINS RESPONSIBLE TO ENSURE THAT ALL THE


GUIDELINES, STANDARDS DRAWINGS, STANDARD AND SPECIFICATIONS
OF THE PUBLIC WORKS AND INFRASTRUCTURE DEVELOPMENT
DEPARTMENT HAVE BEEN MET AND ARE COMPLIED WITH.

9. FINAL POSITION OF SERVICES TO BE DETERMINED ON SITE WITH THE


x x x x x x APPROVAL OF THE ENGINEER.
A
500
G H
x

E J K WATER SERVICES

500
x x x x x x 1. THE CONTRACTOR SHALL NOT OPERATE ANY WATER VALVE OR OTHER
32mmØ 32mmØ FITTINGS WITHOUT THE PERMISSION OF JOHANNESBURG WATER (PTY)
LTD.

32mmx25mmØ 25mmØ
2. COVER TO WATER MAINS
500

A B
500 C C 25mmØ
H G MINIMUM MAXIMUM
J E
C GRAVEL ROAD 900mm 1500mm

x
x

x
SURFACE ROAD 800mm 1500mm
PEDESTRIAN ARES 600mm 1500mm
x

32mmØ 3. ALL WATER MAINS ARE TO BE INSTALLED AT 2 METERS FROM ERF


25mmØ 32mmx25mmØ BOUNDARIES UNLESS OTHERWISE SHOWN ON THE DRAWING.

25mmØ B
SINGLE ERF 4. NO HOSE CONNECTION ARE ALLOWED TO BE DIRECTLY ON PIPES WITH A
DIAMETER LARGER THAN 200mm.

SINGLE ERF CONNECTION 5. ANCHOR BLOCKS CONSTRUCTED ARE TO PROPERLY SHUTTERED AND
CAST AGAINST UNDISTURBED GROUND ANY OVER EXCAVATION IS TO BE
CONNECTION TYPE -2 FILLED WITH MASS CONCRETE.

x
x

x
TYPE -1
MAIN SUPPLY >= 110mm PVC
x

SERVICE MAKERS
ERF BOUNDARIE

ERF BOUNDARIE
1. POSITION OF THE VALVE OR PIPE CROSSING THE ROAD MUST BE MARKED
AS SPECIFIED

2. COVER SLAB OF VALVE BOX TO BE PAINTED:


ISOLATION VALVE OPEN : BLUE
BUILDING BUILDING
ISOLATION VALVE CLOSED : RED
SCOUR VALVE : GREEN
AIR VALVE : BROWN

x
x

x
3. SERVICE MARKER POST TO BE USED AT GRAVEL ROADS (NO KERBS
AVAILABLE).
x

x x x x x x x x x x x x

YARD CONNECTION ERF CONNECTION HORIZONTAL DRILLING ERF CONNECTION YARD CONNECTION

x
ERF CONNECTION YARD CONNECTION
SCHEDULE OF FITTINGS
J
NOTES:
500
DOUBLE TYPE-1 DOUBLE TYPE-2 SINGLE TYPE-1 SINGLE TYPE-2
1. ALL HDPE PIPES SHALL COMPLY WITH SANS 4427 AND SHALL
DESCRIPTION SIZE (mm) No. off No. off No. off No. off BE PN 16 PE100 SDR11.

ERF BOUNDARIE
A 63 - 160mm DN SADDLE 32mm (BSP) 1 1 1 1 2. ALL FITTINGS SHALL COMPLY WITH SANS 14236 AND BE
JASWIC CERTIFIED, CLASS PN16

x
B 90º TEE WITH THREADED MALE OR 90º ELBOW WITH MALE 32 X 1.1/2" X 32 OR 32 X 1.1/2" 1 1 1 1
3. ALL SADDLES SHALL COMPLY WITH SANS 1808-44 AND BE
C HDPE PIPE (ERF CONNECTION) 32mm LENGTH <5m LENGTH >5m up to 20m LENGTH <5m LENGTH >5m up to 20m JASWIC CERTIFIED, CLASS PN16 G
E H
D 90º REDUCING TEE 32mm X 25mm 1 1 4. NO LOW DENSITY AGRICULTURAL PIPES ARE ACCEPTABLE. N.G.L. N.G.L.

400
E REDUCING COUPLING 32mm X 25mm 1 1 5. MINIMUM OF 900mm COVER ON PIPES CROSSING THE ROAD
RESERVE.
F 90° ELBOW 25mm 2 2
B
6. SHALLOW PIPE TRENCHING MY NOT BE LESS THEN 400mm TO 32mmx25mmØ 25mmØ
G CIRCULAR VALVE BOX & COVER LID 6" 1 1 1 1 COVER OF PIPE WITH A TRANSITION LENGTH OF 2.5m (1:5 25mmØ
GRADIENT)
H COMPRESSION STOPCOCK 25mm 1 1 1 1 32mmØ
7. SPECIAL CARE SHALL BE TAKEN DURING THE INSTALLATION K
J JW METER 25mm 1 1 1 1 TO AVOID KINKS IN PIPE.
K HDPE PIPE (YARD CONNECTION) 25mm LENGTH 10m LENGTH 10m LENGTH 10m LENGTH 10m C

TYPICAL ERF CONNECTION SECTION


MAIN SUPPLY >= 110mm PVC A

BOSCH STEMELE (PTY) LTD.


P.O.BOX 4416, RANDBURG, 2125.
SURVEYED
JOHANNESBURG WATER (PTY) LTD CITY OF JOHANNESBURG SCALE AMENDMENTS APPR. DATE DRAWING NO.
PETER PLACE OFFICE PARK, BLOCK G, DESIGNED N.N. 05.2018 DESIGN
54 PETER PLACE, BRYANSTON,
17 HARRISON STREET ORANGE FARM ON A0
JOHANNESBURG, RSA
TELEPHONE: (011) 706 - 4558
DRAWN P.S. 05.2018 MANAGER 10069-02-A-0819
MARSHALLTOWN
TELEFAX:
E-mail:
(011) 463 - 0492
bsjhb@boschstemele.co.za
www.boschstemele.co.za
CHECKED
SERVICES CHECKED
C.P. 05.2018
2107
WATER UPGRADES ISSUED FOR : REV:
REGIONAL OFFICES IN:
AS TENDER
CAPE TOWN • EAST LONDON • PORT ELIZABETH • DURBAN GEOTECH INVESTIGATION CONTRACT A SHOWN
T
COPYRIGHT AND USE OF THIS DRAWING IS RESERVED BY BOSCH STEMELE SERVITUDES TEL: (011) 688-1400 FILE NO.
JW13859
PROJECT NO. DRAWING NO. FILE NO. APPROVED: C. PRINSLOO
FAX: (011) 688-1529 ERF & YARD CONNECTION DETAIL DATE
JW13859 10069-02-A-0819 JW13859 PR. ENG. NO: 201270273 22-06-2018 T ISSUED FOR TENDER C.P. 06-2018 CONTRACT NO. JW13859