Marca PLC

LOGO!
S7-200
S7-300, S7-400, C7, WinAC
Siemens
S7-1200
S7-1200, S7-1500, S7-300, S7-400,
WinAC
PLC5

SLC-500, Micrologix 1500, 1200, 1100


Allen-Bradley - Rockwell Automation

ControlLogix, CompactLogix

Schneider Electric Twido


TSX Premium
TSX Quantum
Zelio

312 Data mem


prog mem
313 Data mem
prog mem
314 Data mem
prog mem
318 Data mem
prog mem

DH+ = MPI?
Software Versión
LOGO!Soft 8.0
Step 7 - Micro/WIN V 4.0.4.16 / 4.0 SP4
Step 7 - Professional 5.5
Step 7 - TIA Portal - Basic V12

Step 7- TIA Portal - Professional V12

RSLogix 5 --

RSLogix 500 + RSLinx --

RSLogix 5000 + RSLinx + RSNetworx

Twido Suite

6k
20k
12k
20k - eprom 4mb
32kb
48kb
Instalador Simulador
Si No
Si No
Si PLC SIM
No PLC SIM

Si PLC SIM

No

No

No

No
No
No
No
Loop Type Controller
Flow PI Durchfluss
Level PI Pegel
Temperature PID Temperatur
Pressure (Liquid) PI Druck
Pressure (Gas) PID

Encoders
Absoluto Posición angular
Distancia
Velocidad
Incremental
Posición Lineal
Contador
Marca HMI
Siemens
Software Versión
Simatic WinCC Flexible 2008
Step 7 - TIA Portal - Basic V12
Step 7 - TIA Portal - Professional V12
Instalador
Si
Si
Si
Marca Equipo
SENTRON
Siemens SIMOVERT, MICROMASTER,
SIMOREG
Software Versión
Powerconfig V3.6

DriveMonitor
Instalador
Si

No
Addressing
X<Slot><Point>
Bits Bytes Words Double Bits
I0.0 Q0.0
I0.1 Q0.1
I0.2 Q0.2
I0.3 Q0.3
IB0
I0.4 Q0.4
I0.5 Q0.5
I0.6 Q0.6
I0.7 Q0.7
IW0
I1.0 Q1.0
I1.1 Q1.1
I1.2 Q1.2
I1.3 Q1.3
IB1
27648 20mA I1.4 Q1.4
I1.5 Q1.5
I1.6 Q1.6
I1.7 Q1.7
ID0
I2.0 Q2.0
I2.1 Q2.1
I2.2 Q2.2
I2.3 Q2.3
IB2
I2.4 Q2.4
I2.5 Q2.5
I2.6 Q2.6
I2.7 Q2.7
IW1
I3.0 Q3.0
I3.1 Q3.1
I3.2 Q3.2
I3.3 Q3.3
IB3
I3.4 Q3.4
I3.5 Q3.5
I3.6 Q3.6
I3.7 Q3.7
Bytes Words Double Bits Bytes Words Double
M0.0
M0.1
M0.2
M0.3
QB0 MB0
M0.4
M0.5
M0.6
M0.7
QW0 MW0
M1.0
M1.1
M1.2
M1.3
QB1 MB1
M1.4
M1.5
M1.6
M1.7
QD1 MD0
M2.0
M2.1
M2.2
M2.3
QB2 MB2
M2.4
M2.5
M2.6
M2.7
QW1 MW1
M3.0
M3.1
M3.2
M3.3
QB3 MB3
M3.4
M3.5
M3.6
M3.7
Bits Bytes Words Double
DB0.DBX0.0
DB0.DBX0.1
DB0.DBX0.2
DB0.DBX0.3
DB0.DBB0
DB0.DBX0.4
DB0.DBX0.5
DB0.DBX0.6
DB0.DBX0.7
DB0.DBW0
DB0.DBX1.0
DB0.DBX1.1
DB0.DBX1.2
DB0.DBX1.3
DB0.DBB1
DB0.DBX1.4
DB0.DBX1.5
DB0.DBX1.6
DB0.DBX1.7
DB0.DBD1
DB0.DBX2.0
DB0.DBX2.1
DB0.DBX2.2
DB0.DBX2.3
DB0.DBB2
DB0.DBX2.4
DB0.DBX2.5
DB0.DBX2.6
DB0.DBX2.7
DB0.DBW1
DB0.DBX3.0
DB0.DBX3.1
DB0.DBX3.2
DB0.DBX3.3
DB0.DBB3
DB0.DBX3.4
DB0.DBX3.5
DB0.DBX3.6
DB0.DBX3.7
Addressing
%X<Rack><Slot><Point>
Bits Words Bits
%I0.0.0 %Q0.0.0
%I0.0.1 %Q0.0.1
%I0.0.2 %Q0.0.2
%I0.0.3 %Q0.0.3
%I0.0.4 %Q0.0.4
%I0.0.5 %Q0.0.5
%I0.0.6 %Q0.0.6
%I0.0.7 %Q0.0.7
%IW0
%I0.1.0 %Q0.1.0
%I0.1.1 %Q0.1.1
%I0.1.2 %Q0.1.2
%I0.1.3 %Q0.1.3
%I0.1.4 %Q0.1.4
%I0.1.5 %Q0.1.5
%I0.1.6 %Q0.1.6
%I0.1.7 %Q0.1.7
%I0.2.0 %Q0.2.0
%I0.2.1 %Q0.2.1
%I0.2.2 %Q0.2.2
%I0.2.3 %Q0.2.3
%I0.2.4 %Q0.2.4
%I0.2.5 %Q0.2.5
%I0.2.6 %Q0.2.6
%I0.2.7 %Q0.2.7
%IW1
%I0.3.0 %Q0.3.0
%I0.3.1 %Q0.3.1
%I0.3.2 %Q0.3.2
%I0.3.3 %Q0.3.3
%I0.3.4 %Q0.3.4
%I0.3.5 %Q0.3.5
%I0.3.6 %Q0.3.6
%I0.3.7 %Q0.3.7
Words Bits Bytes Words Double
%M0.0.0
%M0.0.1
%M0.0.2
%M0.0.3
%M0.0.4
%M0.0.5
%M0.0.6
%M0.0.7
%QW0 %MW0
%M0.1.0
%M0.1.1
%M0.1.2
%M0.1.3
%M0.1.4
%M0.1.5
%M0.1.6
%M0.1.7
%M0.2.0
%M0.2.1
%M0.2.2
%M0.2.3
%M0.2.4
%M0.2.5
%M0.2.6
%M0.2.7
%QW1 %MW1
%M0.3.0
%M0.3.1
%M0.3.2
%M0.3.3
%M0.3.4
%M0.3.5
%M0.3.6
%M0.3.7
Bits Descripción
%S0 Coldstart
%S1 Warmstart
%S2 -
%S3 -
%S4 10 ms
%S5 100 ms
%S6 1s
%S7 1m
%S8 -
%S9 Outdis
%S10 IOErr
%S11 WDG
%S12 PLC Running
Addressing
X:<Slot>.<Word>/<Point>
Bits Bits
I:1.0/0 O:1.0/0
I:1.0/1 O:1.0/1
I:1.0/2 O:1.0/2
I:1.0/3 O:1.0/3
I:1.0/4 O:1.0/4
I:1.0/5 O:1.0/5
I:1.0/6 O:1.0/6
I:1.0/7 O:1.0/7
I:1.1/0 O:1.1/0
I:1.1/1 O:1.1/1
I:1.1/2 O:1.1/2
I:1.1/3 O:1.1/3
I:1.1/4 O:1.1/4
I:1.1/5 O:1.1/5
I:1.1/6 O:1.1/6
I:1.1/7 O:1.1/7
I:1.2/0 O:1.2/0
I:1.2/1 O:1.2/1
I:1.2/2 O:1.2/2
I:1.2/3 O:1.2/3
I:1.2/4 O:1.2/4
I:1.2/5 O:1.2/5
I:1.2/6 O:1.2/6
I:1.2/7 O:1.2/7
I:1.3/0 O:1.3/0
I:1.3/1 O:1.3/1
I:1.3/2 O:1.3/2
I:1.3/3 O:1.3/3
I:1.3/4 O:1.3/4
I:1.3/5 O:1.3/5
I:1.3/6 O:1.3/6
I:1.3/7 O:1.3/7
Bits
B3:1.0/0
B3:1.0/1
B3:1.0/2
B3:1.0/3
B3:1.0/4
B3:1.0/5
B3:1.0/6
B3:1.0/7
B3:1.1/0
B3:1.1/1
B3:1.1/2
B3:1.1/3
B3:1.1/4
B3:1.1/5
B3:1.1/6
B3:1.1/7
B3:1.2/0
B3:1.2/1
B3:1.2/2
B3:1.2/3
B3:1.2/4
B3:1.2/5
B3:1.2/6
B3:1.2/7
B3:1.3/0
B3:1.3/1
B3:1.3/2
B3:1.3/3
B3:1.3/4
B3:1.3/5
B3:1.3/6
B3:1.3/7
Bits Descripción
%S0 Coldstart
%S1 Warmstart
%S2 -
%S3 -
%S4 10 ms
%S5 100 ms
%S6 1s
%S7 1m
%S8 -
%S9 Outdis
%S10 IOErr
%S11 WDG
%S12 PLC Running
Addressing
Local:<Slot>:X.Data.<Slot>
Bits Bits
Local:1:I.Data.0 Local:1:O.Data.0
Local:1:I.Data.1 Local:1:O.Data.1
Local:1:I.Data.2 Local:1:O.Data.2
Local:1:I.Data.3 Local:1:O.Data.3
Local:1:I.Data.4 Local:1:O.Data.4
Local:1:I.Data.5 Local:1:O.Data.5
Local:1:I.Data.6 Local:1:O.Data.6
Local:1:I.Data.7 Local:1:O.Data.7
Local:2:I.Data.0 Local:2:O.Data.0
Local:2:I.Data.1 Local:2:O.Data.1
Local:2:I.Data.2 Local:2:O.Data.2
Local:2:I.Data.3 Local:2:O.Data.3
Local:2:I.Data.4 Local:2:O.Data.4
Local:2:I.Data.5 Local:2:O.Data.5
Local:2:I.Data.6 Local:2:O.Data.6
Local:2:I.Data.7 Local:2:O.Data.7
Local:3:I.Data.0 Local:3:O.Data.0
Local:3:I.Data.1 Local:3:O.Data.1
Local:3:I.Data.2 Local:3:O.Data.2
Local:3:I.Data.3 Local:3:O.Data.3
Local:3:I.Data.4 Local:3:O.Data.4
Local:3:I.Data.5 Local:3:O.Data.5
Local:3:I.Data.6 Local:3:O.Data.6
Local:3:I.Data.7 Local:3:O.Data.7
Local:4:I.Data.0 Local:4:O.Data.0
Local:4:I.Data.1 Local:4:O.Data.1
Local:4:I.Data.2 Local:4:O.Data.2
Local:4:I.Data.3 Local:4:O.Data.3
Local:4:I.Data.4 Local:4:O.Data.4
Local:4:I.Data.5 Local:4:O.Data.5
Local:4:I.Data.6 Local:4:O.Data.6
Local:4:I.Data.7 Local:4:O.Data.7
Bits
Local:1:O.Data.0 B3[0].0 B3[3].0
Local:1:O.Data.1 B3[0].1 B3[3].1
Local:1:O.Data.2 B3[0].2 B3[3].2
Local:1:O.Data.3 B3[0].3 B3[3].3
BYTE
Local:1:O.Data.4 B3[0].4 B3[3].4
Local:1:O.Data.5 B3[0].5 B3[3].5
Local:1:O.Data.6 B3[0].6 B3[3].6
Local:1:O.Data.7 B3[0].7 B3[3].7
Local:2:O.Data.0 B3[1].0 B3[3].8
Local:2:O.Data.1 B3[1].1 B3[3].9
Local:2:O.Data.2 B3[1].2 B3[3].10
Local:2:O.Data.3 B3[1].3 B3[3].11
BYTE
Local:2:O.Data.4 B3[1].4 B3[3].12
Local:2:O.Data.5 B3[1].5 B3[3].13
Local:2:O.Data.6 B3[1].6 B3[3].14
Local:2:O.Data.7 B3[1].7 B3[3].15
DINT
Local:3:O.Data.0 B3[2].0 B3[3].16
Local:3:O.Data.1 B3[2].1 B3[3].17
Local:3:O.Data.2 B3[2].2 B3[3].18
Local:3:O.Data.3 B3[2].3 B3[3].19
Local:3:O.Data.4 B3[2].4 B3[3].20
Local:3:O.Data.5 B3[2].5 B3[3].21
Local:3:O.Data.6 B3[2].6 B3[3].22
Local:3:O.Data.7 B3[2].7 B3[3].23
INT
Local:4:O.Data.0 B3[2].8 B3[3].24
Local:4:O.Data.1 B3[2].9 B3[3].25
Local:4:O.Data.2 B3[2].10 B3[3].26
Local:4:O.Data.3 B3[2].11 B3[3].27
Local:4:O.Data.4 B3[2].12 B3[3].28
Local:4:O.Data.5 B3[2].13 B3[3].29
Local:4:O.Data.6 B3[2].14 B3[3].30
Local:4:O.Data.7 B3[2].15 B3[3].31
Bits Descripción
%S0 Coldstart
%S1 Warmstart
%S2 -
%S3 -
%S4 10 ms
%S5 100 ms
%S6 1s
%S7 1m
%S8 -
%S9 Outdis
%S10 IOErr
%S11 WDG
%S12 PLC Running
PLC
Symbol (Tag) Address
DAServer
Item Reference
Intouch
Item

Diagnostics - Device Groups - Topic Muestra son los ITEMS


Las variables Locales no se ven en el intouch
PLC
Signal
DAServer
Item Name Group Name
Intouch
Tagname Topic

PLC
Prueba de Boboina2

PLC
Reset_Supv
PLC
Signal
DAServer
Signal Signal
Intouch
Signal Signal

PLC
B3[0].10
DAServer
B3[0].10 Prueba_Boboina_2
Intouch
B3[0].10 Prueba_Boboina_2

PLC
%M5
DAServer
6 P_Reset_Sup
Intouch
P_Reset_Sup P_Reset_Sup