Professional Documents
Culture Documents
for Boiler
Feedpump
Recirculation
Applications
2 Superior Pump Protection
Heat rate losses, unit load limitations and frequent trim replacement
Control the fluid velocities (the major contributor to leakage and erosion
problems.)
Provide block valve (MSS-SP-61) shutoff to protect the valve and eliminate
losses.
Velocity (H20)
Service Conditions ft/s m/s
Continuous service single phase fluids 100 30
Cavitating & multi-phase fluid outlet 75 23
MSS-P61 Shutoff
Repeatable block valve
“drop tight” shutoff.
Disk Stack Labyrinth Grooves
This section of the disk stack has no
flow passages; labyrinth grooves in
this section break up clearance flow,
preventing seat ring damage.
Seat Ring
300 series stainless coins with
1500+ PLI to provide long-term
repeatable shutoff.
BW SW
Nominal Trim Globe “A” Angle “A” “B”
Connections Connections
5.75 in.
2.0, 2.5, 2.0, 2.5 in.
11.50 in. (146 mm) IN 56.00 in.
2.0 in. 1.5 in. 3.0, 4.0 in. SCH 40, 80,
(292 mm) 4.50 in. (1422 mm)
SCH 40, 80, 160, XXS 160, XXS
(114 mm) OUT
2.5 in.
26.00 in. 13.25 in 56.00 in. 3.0, 4.0 in.
3.0 in. 2.0 in. SCH 40, 80,
(660 mm) (330 mm) (1422 mm) SCH 40, 80, 160, XXS
160, XXS