Multiplex Drilling Control Systems

Portable Electronic
Test Unit
Portable Electronic Test Unit
The design of the Portable Electronic Test Unit is based upon a standard laptop computer. It can be used to simulate a
control pod for testing of either control panel without a pod or it can be used in place of a panel to operate any BOP stack
function. The Test Unit also permits changes to the surface software system utilizing the software development package.

The Portable Electronic Test Unit consists of an IBM The Portable Electronic Test Unit can be used to per-
compatible laptop PC, a control pod electrical power supply, form specified tests automatically. For example, a typical
a modem and interconnection test cables. The software is test after changing out components in the control pod may
written in a high level language which can be run on any be to operate the component function several times (for
standard IBM compatible PC. The Test Unit is housed in a example 10 or 15) to confirm proper operation.
robust case designed to IP65 environmental standards. An The Test Unit can also be used to control a pod while it
optional, ruggedized, water-resistant case is also available. is on the BOP stack. This may be helpful when access to a
All of the control panel commands are available on the control panel is not possible.
Test Unit. Additional test functions and test control PC Specifications:
sequences are also provided. Information displayed on the Processor: 80286 based or higher, 25 MHz minimum
screen informs the operator about the complete status of RAM: 1 Mbyte, minimum.
the pod. All analog values, solenoid coil status data and
Disk Drive: 5-1/4" or 3-1/2"
diagnostic data are accessible with a simple keystroke or
Monitor: VGA compatible
mouse click.
Ports: 2 serial, 1 parallel

Setup Analog Data Digital Data Valve Data Toggle Valve Quit

An example of System Status


VS10x >
one of the VS11x >
Supply Voltage 28.7 V OK
Portable
Electronic Test VS110VS110
Unit screens is Analog Data VS111VS111
shown here, VS112VS112
showing system Annular Preventer Pilot Pressure PT101 VS113VS113
status and analog Status : OK 8.8 mA VS114VS114 VS115
VS115VS116
data readouts.
BOP Pilot Pressure PT102 VS116VS117 VS118
Status : OK 8.8 mA VS117VS119
VS118
Subsea Accumulator Pressure PT106 VS119
Status : OK 8.8 mA

BOP Pilot Operating PT105


Status : OK 8.8 mA = 112 barg

Annular Preventer Operating Pressure PT104


Status : OK 8.8 mA = 112 barg

Switch VS110 on

Cameron P O Box 1212 • Houston, Texas 77251 1212 • Phone 713 683 4600 • Fax 713 683 4306 • http://www.camerondiv.com
Cameron GmbH Lueckenweg 1 • 29227 Celle Germany • Phone 011 49 5141 8060 • Fax 011 49 5141 806333

© Cooper Cameron Corporation, Cameron Division, Printed in USA, 3/97,1CHC, TC1145