DESCRIPTION
The nVent RAYCHEM PMKG-LS is a NEMA Type 4X rated splice
kit designed for use with RAYCHEM BTV-CR, BTV-CT, QTVR-CT,
LBTV2-CT, and KHP-CR parallel heating cables. It is designed to
be placed on the pipe, under the insulation and cladding.
For additional information contact your nVent representative or
call (800) 545-6258.
TOOLS REQUIRED
• Wire cutters • Screwdriver
• Needlenose pliers • Utility knife
A
Nonhazardous Locations F
KIT CONTENTS
Item Qty Description
A 1 Body E
B
B 2 Pressure plates with captive screws
C 2 Red grommets (not for use with LBTV2)
D 2 Gaskets
E 2 Covers with captive screws D
C
F 1 Label
WARNING:
This component is an electrical device that must be • Component approvals and performance are based • Bus wires will short if they contact each other.
installed correctly to ensure proper operation and to on the use of nVent-specified parts only. Do not Keep bus wires separated.
prevent shock or fire. Read these important warnings use substitute parts or vinyl electrical tape. • Use only fire-resistant insulation materials, such
and carefully follow all of the installation instructions. • The black heating cable core is conductive and can as fiberglass wrap or flame-retardant foam.
• To minimize the danger of fire from sustained short. It must be properly insulated and kept dry.
electrical arcing if the heating cable is damaged • Damaged bus wires can overheat or short. Do
or improperly installed, and to comply with the not break bus wire strands when scoring the
requirements of nVent, agency certifications, and jacket or core.
National Electrical Codes, ground-fault equipment • Keep components and heating cable ends dry
protection must be used. Arcing may not be before and during installation.
stopped by conventional circuit breakers.
IDENTIFY HEATING CABLE TYPE
Bus wire
WARNING: Use of the wrong grommet can result
in leaks, cracked components, shock or dielectric BTV-CR, BTV-CT, QTVR-CT, LBTV2-CT, KHP-CR
failure, and will invalidate approvals and
certifications.
1 2
• Allow extra heating cable as shown. • Slide parts onto heating cable in order shown.
12 in
(30 cm)
Center-line of
connection body
3 4
Do not cut braid.
• Push braid back to
create a pucker.
4 in
(100 mm)
• At pucker use a
screwdriver to
open braid.
2 | nVent.com
5 6
• Pull braid tightly to center of cable to make a pigtail. Do not cut bus wires
3 1/2 in
(89 mm)
7 8
1/4 in
(5 mm) • Peel core free from bus wire.
• Twist back and
peel bus wire • Clean bus wires.
from core.
9 10
• Push heating cable into the body. • Remove screws, lockwashers and clamps.
• Slide grommets into cavities and seat. • Push braid wires away from bus wires.
• Tighten pressure plate screws to body. • Position wires on blocks.
• Refit clamps, lockwashers, screws, and tighten.
• Trim all extra lengths of wire and remove any loose wires.
Trim
Do not allow braid
to contact bus wires Trim
1
2 1
AII
B
2
AII
B
3
3
nVent.com | 3
11 12
• Remove release liner, if present, from gasket. • Tape splice connection to pipe.
• Position gaskets and covers on body. • Loop and tape extra heating cable to pipe.
• Tighten covers to body. • Apply insulation and cladding.
• Install label on outside of cladding.
• Leave these instructions with the end user
for future reference.
North America Europe, Middle East, Africa Asia Pacific Latin America
Tel +1.800.545.6258 Tel +32.16.213.511 Tel +86.21.2412.1688 Tel +1.713.868.4800
Fax +1.800.527.5703 Fax +32.16.213.604 Fax +86.21.5426.3167 Fax +1.713.868.2333
thermal.info@nvent.com thermal.info@nvent.com cn.thermal.info@nvent.com thermal.info@nvent.com
nVent.com
©2018 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners.
nVent reserves the right to change specifications without notice.
Raychem-IM-H54256-PMKGLS-EN-1805 PN 305209-000