8.00
1.00 3.70 3.30
A B C D E
Y
W2 W4 8.00
1 1.00 3.70 3.30
MAID'S
T&B
2.00 QUARTER 2.00 Y
DN
W2 D4 W2 D2
D5
2 DN
2
D3 FAMILY ROOM
KITCHEN
2.50 W2 DINING AREA SERVICE 2.50 2.50
OPEN
W2 2.50
BELOW
W2 AREA
3 UP 3 DN
T&B UP T&B
2.00 W4 2.00 2.00 W4 2.00
X W I C D5 12.00 X D5
8.50
4 13.00 4
D2 MASTER'S D2
LIVING AREA BEDROOM 2.30
11.00
OPEN 2.30
2.50 W2 UP 2.50 W3 BEDROOM
BELOW
UP
5 W2
5
W3
1.50 D1 1.70 1.50 D2 1.70
W1 W1
6 6
GARAGE BALCONY
PORCH 1.50
2.50 2.50
UP
7 7
RAMP UP 3.00 2.00 3.00
8.00
3.00 2.00 3.00
8.00
APPEX
0.40mm RIDGE CAP APPEX
0.40mm RIDGE CAP
*VARIES* 0.40mm RIB TYPE 0.40mm RIB TYPE
*VARIES*
ANALOK TYPE
WINDOW
T.O.B. T.O.B.
2.10 x 0.90m
PANEL DOOR
2.80 2.80
2.10 x 0.90m
PANEL DOOR
S.F.L. S.F.L.
3.00 3.00
F.F.L. F.F.L.
0.40 N.G.L. 0.40 N.G.L.
APPEX
0.40mm RIDGE CAP APPEX
0.40mm RIDGE CAP
*VARIES* *VARIES*
ANALOK TYPE
WINDOW
T.O.B. T.O.B.
2.10 x 0.90m ANALOK TYPE
PANEL DOOR WINDOW
2.10 x 0.90m
2.80 2.80
PANEL DOOR
S.F.L. S.F.L.
3.00 3.00
F.F.L. F.F.L.
0.40 N.G.L. 0.40 N.G.L.
APPEX APPEX
*VARIES* *VARIES*
T.O.B. T.O.B.
2.80 2.80
3.00 3.00
MASTER'S MAID'S
F.F.L. LIVING AREA BEDROOM F.F.L. MASTER'S BEDROOM WIC KITCHEN QUARTER
0.40 N.G.L. 0.40 N.G.L.
PANEL FLUSH PANEL FLUSH FLUSH ANALOK TYPE ANALOK TYPE ANALOK TYPE ANALOK TYPE
DOOR TYPE DOOR TYPE DOOR TYPE DOOR TYPE DOOR TYPE WINDOW WINDOW WINDOW WINDOW
0.70
1.20 1.20
1.80
2.10
1.40
0.90 0.90
0.30
D1 D2 D3 D4 D5 W1 W2 W3 W4
DN
UP
1
8"
THK FICEM BOARD ON
METAL FURRING SPACED
1
@ 0.60m, O.C. BOTHWAYS 8"
THK FICEM BOARD ON
METAL FURRING SPACED
@ 0.60m, O.C. BOTHWAYS
RAMP UP
3.70 3.30
Y
RB RB
2
RB
RB
2.50 2.50
RB RB
3
RB
RB
RB
RB
2.00 2.00
X
8.50 8.50
4 RB
RB
RB
RB
2.50 2.30
5 RB
RB
1.70
RB
1.50
FB
6 RB RB
7.00
Y
C5F1 C5F1
TB/WF
1
TB/WF
TB/WF
TB/WF
ON FILL ON FILL
2.00 EL. 0.40 m. EL. 0.40 m. 2.00
C4F1 C2F1 C2F1 Y
TB/WF FB FB
2 TB/WF
2
TB/WF
TB/WF
ON FILL OPEN
FB
FB
FB
2.50 EL. 0.40 m. 2.50 2.50 2WS 2.50
BELOW
C4F1 C1F2 C2F1
TB/WF FB FB
3 3
TB/WF
TB/WF
TB/WF
TB/WF
ON FILL ON FILL
FB
FB
FB
FB
2.00 EL. 0.40 m. EL. 0.40 m. 2.00 2.00 2WS 2WS 2.00
X C4F1 C1F2 C2F1 12.00 X
8.50
4 13.00
0.10 m. THK. CONCRETE
SLAB REINFORCED WITH
10 mm Ø BAR SPACED @ TB/WF
4 FB
0.60 m. O.C. B.W.
2WS
TB/WF
TB/WF
ON FILL 11.00
FB
FB
2.30 2.30
FB
EL. 0.40 m.
2.50 2.50
TB/WF
C5F1
C4F1 C6F1 C2F1 ON FILL
EL. 0.40 m. 2WS
TB/WF
5 5
TB/WF
TB/WF
FB FB
FB
1.50 TB/WF 1.70 1.50 1.70
FB
C1F2 C5F1
TB/WF TB/WF
FB
6 ON FILL
6 FB FB
FB
FB
EL. 0.40 m. ON FILL 2WS
EL. 0.40 m. 1.50
2.50 2.50
C4F1 C4F1
7 7 FB
0.20 (TYP.)
PLAN
F.F.L.
300mm x 300mm SEMI RUSTIC TILES
10mmØ STIFF. BAR
SPCD. @ 0.30m O.C. T.O.B.
GRAVEL BED
0.20
COMPACTED
SUBGRADE 0.10
3.00
0.20 0.90
0.80
1 STAIR DETAIL
SCALE
A-8 NTS
2 SECTION 3 SECTION
SCALE
A-8 SCALE 1:150M A-8
SCHEDULE OF COLUMNS
MARK C1 C2 C3 C4 C5 2ND FLOOR
END SPAN
END SPAN
AS SHOWN ( END
0.35 SPAN)
AS SHOWN ( END
0.35 SPAN)
AS SHOWN ( END
0.35 SPAN)
3 SCHEDULE OF WALL FOOTING
SCALE NTS
A-10
4 - 12mm dia. RSB 7 - 16mm dia. RSB 4 - 12mm dia. RSB SEE SCHEDULE OF WALL
MID SPAN
MID SPAN
MID SPAN
AS SHOWN (MID AS SHOWN (MID AS SHOWN (MID
0.35
SPAN)
0.35
SPAN)
0.30
SPAN) VERIFY
TB 1 FB 1 RB 1 F.G.L.
NOT TO
2 SCHEDULE OF BEAM SCALE
A-10 SCALE NTS
D PLAN
SEE SCHEDULE OF WALL FOOTING
T GRAVEL BED
MARK W1 W2 h
COMPACTED SUBGRADE
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORINGS AND 1. PROVIDE SUFFICIENT/STANDARD SHEATING, JOISTS, FOOTINGS, SHORES SPCD. AT 4' O.C.B.W.
BRACINGS OF THE STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION.
2. USE 38" FORM PLYWOOD W/ STANDARD STUDS & STRINGERS.
B. CONCRETE AND REINFORCEMENT
3. USE 2" PRE-CAST CONCRETE SPACER PROPERLY TIED ON STIRRUPS/TIES.
1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING CODE OF
THE PHILIPPINES. E. STRUCTURAL STEEL
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE END OF 1. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTMA-36 Fy = 36,000 psi
TWENTY EIGHT (28) DAYS WITH COSSEPONDING MAXIMUM SIZE AGGREGATE AND SLUMPS AS
FOLLOWS: 2. WELDING SHALL CONFORM TO AWS STANDARDS.
0.40 mm RIDGE ROLL 3. FABRICATION SHALL SUBMIT SHOP DRAWING FOR APPROVAL OF THE CIVIL ENGINEER AND THE
LOCATION 28 DAYS STRENGTH MAX. SIZE AGGREGATE MAX. SLUMP OWNER OF THE FABRICATION.
2" TEKSCREW
2" X 3" X 0.90 mm C PURLINS SPACED @ 0.60m O.C. CURBS, SLAB ON GRADE 2,500 psi (175 kg/sq.cm.) 1 in. (25 mm) 4 in. (100 mm) F. FOUNDATION
FOOTINGS AND FOOTING 3
in. (19 mm)
1/4" THICK 2X2 ANGLE BAR CENTER POST 3,000 psi (210 kg/sq.cm.) 4 4 in. (100 mm) 1. FOUNDATION SHALL REST ON NATURAL SOIL. UNLESS OTHERWISE NOTED BY THE CIVIL
TIE BEAMS
ENGINEER. NO PART OF THE FOUNDATION SHALL REST ON FILL FOR ISOLATED FOOTING.
COLUMNS, BEAMS AND 3,000 psi (210 kg/sq.cm.) 3
in. (19 mm) 4 in. (100 mm)
4
3/16" THICK 2X2 ANGLE BAR WEB MEMBER SLAB
2. THE CONTRACTOR MUST NOTIFY THE CIVIL ENGINEER AFTER FOOTING EXCAVATIONS HAVE
3
OTHERS 3,000 psi (210 kg/sq.cm.) 4 in. (19 mm) 4 in. (100 mm) BEEN COMPLETED AND PRIOR TO CONCRETING OF FOOTING TO CONFIRM THE ASSUMED SOIL
1/4" THICK 2"X2" ANGLE BAR TOP CHORD AND BUTTOM CHORD BEARING CAPACITY USED IN THE DESIGN.
3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 (PNS 49) GRADE 40 FOR DIA. 12 AND TABLE OF LAP SPLICE AND ANCHORAGE LENGTH
SMALLER BARS AND GRADE 60 FOR LARGER BARS, ALL BARS SHALL BE WELDABLE.
LAP SPLICE (m)
MINIMUM LAP SPLICE LENGTH
STANDARD HOOK
2" PVC PIPE DOWN SPOUT 4. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE DETAILING BAR ANCHORAGE (m) UNIT OF COLUMN REINFORCEMENT
DIAMETER LENGTH WEIGHT INDIVIDUAL BARS
0.44mmTHICK #24 SPANISH GUTTER REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO, UNLESS OTHERWISE SHOWN OR (mm)
TENSION BAR COMPRESSION BAR
(mm) (kg/m)
NOTED.
90 DEG. 180 DEG. 270 DEG. TOP BAR BOT. BAR TOP BAR BOT. BAR W/ TIES W/ SPIRAL
6. SPLICES SHALL BE SECURELY WIRED TOGETHER AND SHALL LAP OR EXTEND IN ACCORDANCE 32 1.12 0.56 0.43 1.90 1.35 1.74 1.24 6.327 1.03 0.93
WITH TABLE 1 (TABLE OF LAP SPLICE AND ANCHORAGE LENGTH) UNLESS OTHERWISE SHOWN ON
36 1.43 0.61 0.48 2.40 1.70 2.00 1.40 8.000 1.20 1.05
DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE.
5/8" ANCHOR BOLT WITH NUT
7.ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, SHALL BE PROPERLY POSITIONED AND
SECURED IN PLACE PRIOR TO PLACING OF CONCRETE.
NOTES:
8. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS,
1. ACI SECTION 12.4 STATES THAT DEVELOPMENT LENGTH OF INDIVIDUAL BARS WITHIN A BUNDLE,
TYPICAL TRUSS DETAILS EQUIPMENT AND MECHANICAL BASES THAT ARE REQUIRED BY THE ARCHITECTURAL,
ELECTRICAL, AND MECHANICAL DRAWINGS.
IN TENSION OR COMPRESSION, SHALL BE THAT FOR THE INDIVIDUAL BAR, INCREASED 20% FOR
THREE BAR BUNDLE, AND 33% FOR FOUR-BAR BUNDLE.
SCALE NTS 9. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7) CONSECUTIVE DAYS
2. FOR COLUMNS, AT ANY LEVEL NO MORE THAN ALL ALTERNATE BARS SHOULD BE SPLICED. NOT
IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP, FOG SPRAYING, CURING
MORE THAN 33% OF THE BARS SHALL BE SPLICED WITHIN THE REQUIRED LAP LENGTH. MINIMUM
COMPOUNDS OR OTHER APPROVED METHODS.
DISTANCE BETWEEN TWO ADJACENT BAR SPLICES SHALL BE 600mm.
10. STRIPPING OF FORMS AND SHORES:
3. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 300mm DEPTH OF CONCRETE CAST
BELOW THE REINFORCEMENT.
FOUNDATION . . . . . . 24 HRS.
SUSPENDED SLAB EXCEPT WHEN
4. AS MUCH AS POSSIBLE, SPLICES SUBJECTED TO TENSILE STRESSES ARE DISCOURAGED,
ADDITIONAL LOADS ARE IMPOSED . . . 8 DAYS
THESE SHOULD BE AVOIDED OR PROVIDED WITH STANDARD HOOKS.
WALLS . . . . . . . 18 HRS.
BEAMS . . . . . . . 14 DAYS
CONSTRUCTION NOTES
8.00
2.00 2.00
S S
S2
1 DN
2
2.00 S
2.00 2.00 S 2.00
12.00
S3 S2 8.50
13.00 S
S 11.00
2.50 UP 2.30 2.50
S 2.30
1.50
2.50 2.50
8.00
3.00 2.00 3.00
8.00
8.00
2.00 2.00
10 7
2.50 REF
2.50 2.50 2.50
11
DN
11.00
2.50 UP 2.30 2.50 2.30
1.50
2.50 2.50
8.00
3.00 2.00 3.00
8.00
2. THE CONTRACTOR SHALL VERIFY & ORIENT THE ACTUAL LOCATION OF THE CONCRETE TERMINAL POLE CEILING LIGHT OUTLET
FOR THE CONNECTION OF THE POWER SUPPLY OR TELEPHONE SERVICE.
REF REF OUTLET
3. ALL INSTALLATIONS SHALL BE CONCEALED FROM VIEW, WIRINGS SHALL BE ENCASED IN UPVC #40 EXCEPT
POWER & ELECTRICAL, TELEPHONE LINE SERVICE ENTRANCE W/C SHALL BE ENCASED IN RSC UNLESS
OTHERWISE SPECIFIED. CONVENIENCE OUTLET
4. MINIMUM WIRE & CONDUIT SIZE SHALL BE 2.0mm² & 15mm Ø RESPECTIVELY UNLESS OTHERWISE
SPECIFIED. R RANGE OUTLET
5. PULL BOXES OF APPROPRIATE SIZE SHALL BE PROVIDED EVEN IF NOT INDICATED IN PLAN TO CIRCUITS
ACCOMODATE NUMBER OF SUPPLIES.
8.00
FD
1.00 3.70 3.30
FC
2.00 WC 2.00
LAV
FC
FD FC
DN FD FC
11.00
2.50 UP 2.30 2.50 2.30
1.50
2.50 2.50
8.00
3.00 2.00 3.00
FD
2.00 WC 2.00
CB
LAV
CB
2.50 2.50
KS
FD
CB
FD 2.00 WC 2.00
FC
WC
LAV
CB 12.00
FD
WC
FC SEPTIC
LA
13.00 TANK
V
FC
2.50 UP 2.30
FD
WC
FC CB
LA
V
CB
RA
MP
UP CB
1.50 1.70
CB
1.50
TO WATER DRAINAGE
2.50
CB
TO WATER DRAINAGE
RAMP UP
8.00
WATERLINE LAYOUT
1 ISOMETRIC SEWER AND DRAINAGE
A-16 SCALE NTS
2 LAYOUT
A-16 SCALE 1:100 MTS
8.00
CB
FD
1.00 3.70 3.30 WC
LA
V FD
CB WC
CB LA
V
CB
KS
CE
AGB FD
AIN
DR WC
T ER LA
2.50 2.50 WA V
CB
TO
RA
MP
UP SE
CB TA PTI
NK C
DN FD
2.00 WC 2.00 CE
AGB
AIN
DR
LAV T ER
8.50 WA
TO
11.00
2.50 2.30
SEWER&DRAINAGE LAYOUT
2 ISOMETRIC
A-17 SCALE NTS
1.50 1.70
0.10 0.15
0.72
0.30
0.23 0.33
0.39
0.33
DIGESTIVE CHAMBER 0.41
0.44
1.50
LEACHING LEACHING W.L. 0.47
CHAMBER 1 CHAMBER 2 0.19
0.07 LB8
PF1/2
32Ø
0.73
0.20
0.76
0.56 0.37
0.48
S E C T I O N 0.20
F.L.
0.30 F.L.
WALL HUNG LAVATORY
1
SEPTIC TANK DETAIL LAVATORY AND WATER CLOSET INSTALLATION
A-18 SCALE NTS
2 DETAILS NTS
A-18 SCALE