Professional Documents
Culture Documents
APPLICATION STANDARDS
A halogen free fire resistant, individually screened, NEK 606, IEC 60092-353, EN 60228,
instrumentation and telecommunication cable for fixed
installation. Suitable for use in all marine environments such as Flame Retardant according to IEC/EN 60331, IEC/EN
muddy, dry, wet or oily conditions, meeting the requirement for 60332-3-22, IEC/EN 60332-1-2
NEK 606. Halogen free according to IEC/EN 61034-2, IEC/EN 60754-1/2
CHARACTERISTICS
Voltage Rating Uo/U
150/250V
THE CABLE LAB®
Test Voltage
1.5kV AN ISO/IEC 17025 AND IECEE CBTL ACCREDITED FACILITY
Our world-class testing facility assures the quality and compliance of this cable
Temperature Rating through a continuous and rigorous testing regime.
-40°C to +90°C
SUSTAINABILITY COMMITMENT
CONSTRUCTION We are on a journey to Net Zero.
We've committed to near-term emissions reductions and a net-zero target with the
Conductor Science Based Targets initiative and we're a signatory to the United Nations Global
Class 2 stranded tinned copper conductor Compact Sustainable Development Goals.
Learn more about embodied carbon and our carbon emissions reduction actions,
Tape our comprehensive recycling services, and wider ESG activities for sustainable
Mica glass tape operations at: www.elandcables.com/company/about-us/esg-sustainability
Insulation
Halogen free EPR (Ethylene Propylene Rubber)
Drain Wire
Stranded tinned copper
Screen
TCWB (Tinned Copper Wire Braid)
Sheath
SHF, MUD (halogen free, mud resistant)
Core Identification
Pairs: Black Blue
Triples: Black Blue Brown
Sheath Colour
Blue Grey
DIMENSIONS
ELAND PART NO. NO. OF PAIRS/ NOMINAL CROSS SECTIONAL AREA NOMINAL OVERALL DIAMETER NOMINAL WEIGHT
TRIPLES mm2 mm kg/km
ELAND PART NO. NO. OF PAIRS/TRIPLES NOMINAL CROSS SECTIONAL AREA NOMINAL OVERALL DIAMETER NOMINAL WEIGHT
mm2 mm kg/km
*Eland Part No. shown above designate the gland colour (*). For each colour substitute * for a colour code as listed below. e.g. ASHNBI0175GR = 0.75mm2 Grey
COLOUR CODES
CODE GR BL
CONDUCTORS
NOMINAL CROSS MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C
SECTIONAL AREA ohms/km
mm2
Class 2 Class 5
ELECTRICAL CHARACTERISTICS
NOMINAL CROSS SECTIONAL AREA SINGLE CORE 2 CORE 3 AND 4 CORE 5 CORE
mm2 Amps Amps Amps Amps
1 18 15 13 11
1.5 23 20 16 13
2.5 30 26 21 18
The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is
believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.