You are on page 1of 2

Certificate of Analysis Report No.

HSNDS/PL-24-07
Issue Date: 15-01-2024
Client Name: USAID
PO #: 7200AA24F50006
Quantity: 12000 pcs
Product Name: Plastic Tarpaulin sheet (4 m x 6 m)
Manufacturing Site: Lahore, Pakistan
Standard Atmosphere: ISO- 2231:1989E: Temp: 20 + 2 oC, R.H%: 65 + 4 % Actual
Atmosphere: ISO- 2231:1989E: Temp: 20.3 oC, R.H%: 67.4 %

Sr.
No. Test Name Customer Requirements Test Method Results

Woven high-density polyethylene


(HDPE) black fibers fabric laminated Woven high-density polyethylene
on both sides with low density (HDPE) black fibers fabric laminated
1 Material Physical
polyethylene (LDPE) on both sides with low density
assessment
Recycle content maximum possible polyethylene (LDPE)
without compromising the product Recycle content % age = 25 %
quality
Width = 4000 mm + 1 %
2 Dimensions ISO 22198:06 4009 x 6004 mm
Length = 6000 mm

3 Weight (g/m2) 190g/m² ± 20 g/m² ISO 3801 176.9 g/m²

Minimum 500 N (Both Warp and Warp : 728.6N, E % = 20.3


4 Tensile Strength (N) ISO 1421-1
weft). Elong. % age (15 % - 35%) Weft : 690.5 N, E % = 21.2

As per customer define test Warp : 12 Kg


5 Tear Strength (N) Manual
instructions. Min 10 kg Weft : 12 Kg
Minimum 100 N, Warp : 230.2 N
6 Tear Strength (N) ISO 4674-1B
(Both Warp and weft) Weft : 218.4 N

7 Coating Color ‘L’ value Coordinates Minimum ISO 105 J01 L = 83.7
L : 82
Minimum 50% of the original value
8 Welding Strength (%) ISO 1421-1 84.2 %
of the actual product.
The 4 corner eyelets must be
Corner Eyelets Physical
9 reinforced with black rubber patch Comply (Plastic patch)
reinforcements assessment
or similar

10 Marking Labels Printing paper 80gsm or similar. ISO 3801 80.4 g/m²

Instruction sheet and Physical


11 Preferred: eco-friendly ink Comply
labels assessment
(A4 size or similar) and glue the
Physical
12 Instruction sheet sticker (for double reinforcement) Comply
assessment
onto the plastic sheeting.
The tarpaulin tensile strength
UV resistance of the under ISO 1421-1 after 1500 hours
plain sheet, measured UV under ASTM G53/94 (UVB 313
ISO 1421-1
13 as remaining tensile nm peak] must be: Minimum 80 % Comply
ASTM G53/94
strength after UV of the original value of the actual
exposure product, AND not less than 475N.
To be tested in the plain sheet.
Minimum class D, s2, d2.
14 Flame retardant Minimum time to reach large wing EN13823+A1 Comply
external edge: 4minutes (LFS)
Measured under ISO 13468-1.
Values should be measured
Opacity measured as respectively from 350 to 750nm,
minimum reflection and from 750 to 2500nm
15 and maximum wavelength. The final result is the ISO 13468-1. Comply
transmission, in the average of the averages in each
range of visible light range. Minimum total reflection:
35% Maximum total reflation: 50%.
Maximum total transmission : 5%
Minimum rack able load capacity
of 2,500 lbs (1,134 kgs), dynamic
16 Pallet Capacity load capacity of 2,200 lbs (998 kgs) Lab developed Comply
and a static load capacity of 2,500
lbs (1,134 kgs).

Saeed ul Hassan

Deputy Manager
QC Lab

You might also like