You are on page 1of 5

Confidentiality Class External Confidentiality Label Document Type Page

Ericsson Internal Commercial in Confidence Activity Description 1 (5)

Upgrade SW Router 6000 Ericsson


Prepared By (Subject Responsible) Approved By (Document Responsible) Checked

CC&Q - EGS
Document Number Revision Date Reference

PA1 2020-10-07

Requisitos Básicos:
1 - Ter a Versão de Software compatível com o Modelo do Router;
2 – Colocar a Versão na “raíz” de um pendrive.
3 – Comandos destacados em vermelho e amarelo
login: _cde

Password: Spitfire12345

Last login: Tue Oct 6 13:35:12 on ttyS0

Hello from Router 6675

Copyright (c) 2017 Ericsson AB.

All rights reserved.

[local]SPCL11#show clock

Tue Oct 1 10:15:06 2000 UTC

[local]SPCL11#clock set 2020:10:06:14:29

[local]SPCL11#show clock

Tue Oct 6 14:29:06 2020 UTC

[local]SPCL11#show release

Installed releases:

p01: active (will be booted after next reload)

----------------------------------------------

Version SPR2-CXP9060188_1-R6B107_9999-Release

Built on Thu Aug 23 05:59:46 CEST 2018

Copyright (C) 1998-2018, Ericsson AB. All rights reserved.

p02: alternate

--------------

Version SPR2-CXP9060188_1-R6B107_9999-Release
Confidentiality Class External Confidentiality Label Document Type Page

Ericsson Internal Commercial in Confidence Activity Description 2 (5)


Prepared By (Subject Responsible) Approved By (Document Responsible) Checked

CC&Q - EGS
Document Number Revision Date Reference

PA1 2020-10-07

Built on Thu Aug 23 05:59:46 CEST 2018

Copyright (C) 1998-2018, Ericsson AB. All rights reserved.

[local]SPCL11#show disk external

Filesystem 1k-blocks Used Available Use% Mounted on

/dev/sda1 1952192 737120 1215072 38% /media/flash

[local]SPCL11#dir /media/flash

Contents of /media/flash

total 653728

-rwxr-xr-x 1 root root 1386698 Oct 5 13:07 CDM-2.08.28-WHQL-Certified1.zip

-rwxr-xr-x 1 root root 281505039 May 27 09:25 CXP9060188_1-R13B156_9999_ SF-RP-P1L.tar.gz

-rwxr-xr-x 1 root root 376837572 May 27 09:26 CXP9060188_1-R13B156_9999_SF-RP-P1L_NMS.zip

drwxr-xr-x 2 root root 32768 Oct 5 09:05 System Volume Information

-rwxr-xr-x 1 root root 4815 Oct 1 19:24 TU8SA22619_201001_192115.xml

-rwxr-xr-x 1 root root 1228 Oct 1 19:24 TU8SA22619_201001_192115_info.xml

Nome do arquivo de upgrade. Alterar conforme necessidade

[local]SPCL11#release download /media/flash/CXP9060188_1-R13B156_9999_SF-RP-P1L.tar.gz

The following "alternate" release will be erased:

Version SPR2-CXP9060188_1-R6B107_9999-Release

Built on Thu Aug 23 05:59:46 CEST 2018

Copyright (C) 1998-2018, Ericsson AB. All rights reserved.

Are you sure you wish to erase this release? (y/n) y

Erasing the "alternate" release...

Release erase completed

grep: /opt/ipos/config/spitfire_install.log: No such file or directory

grep: /opt/ipos/config/spitfire_install.log: No such file or directory


Confidentiality Class External Confidentiality Label Document Type Page

Ericsson Internal Commercial in Confidence Activity Description 3 (5)


Prepared By (Subject Responsible) Approved By (Document Responsible) Checked

CC&Q - EGS
Document Number Revision Date Reference

PA1 2020-10-07

grep: /opt/ipos/config/spitfire_install.log: No such file or directory

grep: /opt/ipos/config/spitfire_install.log: No such file or directory

Installing from /media/flash/CXP9060188_1-R13B156_9999_SF-RP-P1L.tar.gz

######Oct 6 14:04:02: %DLM-3-INVALID_TAG: Invalid information tag SWVC

grep: /opt/ipos/config/spitfire_install.log: No such file or directory

#grep: /opt/ipos/config/spitfire_install.log: No such file or directory

grep: /opt/ipos/config/spitfire_install.log: No such file or directory

grep: /opt/ipos/config/spitfire_install.log: No such file or directory

grep: /opt/ipos/config/spitfire_install.log: No such file or directory

Adding extended attribute, please wait ....

##########

Installation completed successfully.

[local]SPCL11#show release

Installed releases:

p01: active (will be booted after next reload)

----------------------------------------------

Version SPR2-CXP9060188_1-R6B107_9999-Release

Built on Thu Aug 23 05:59:46 CEST 2018

Copyright (C) 1998-2018, Ericsson AB. All rights reserved.

p02: alternate

--------------

Version SPR2-CXP9060188_1-R13B156_9999-Release

Built on Sun May 24 06:08:13 CEST 2020

Copyright (C) 1998-2020, Ericsson AB. All rights reserved.

[local]SPCL11#release upgrade
Confidentiality Class External Confidentiality Label Document Type Page

Ericsson Internal Commercial in Confidence Activity Description 4 (5)


Prepared By (Subject Responsible) Approved By (Document Responsible) Checked

CC&Q - EGS
Document Number Revision Date Reference

PA1 2020-10-07

Version SPR2-CXP9060188_1-R13B156_9999-Release

Built on Sun May 24 06:08:13 CEST 2020

Copyright (C) 1998-2020, Ericsson AB. All rights reserved.

Are you sure you wish to continue? (y/n) y

WARNING: Upgrade in progress.. DO NOT POWERCYCLE

Upgrading kernel flash...

Upgrading uboot flash...

Upgrading sbi flash...

Upgrading primary FPGA...

Upgrading...

..........................................................................................................................................................................................................................
.........................

FPGA upgrade OK.

Setting boot partition to "alternate"...

upgrading is done, reload chassis

The "reload" command will reboot all cards on this system

Irá demorar uns 5 – 10 minutos – Tenha paciência

login: _cde

Password:

Last login: Tue Oct 6 14:13:25 on ttyS0

Hello from Router 6675

Copyright (c) 2017 Ericsson AB.

All rights reserved.

[local]SPCL11#show release

Installed releases:

p02: active (will be booted after next reload)


Confidentiality Class External Confidentiality Label Document Type Page

Ericsson Internal Commercial in Confidence Activity Description 5 (5)


Prepared By (Subject Responsible) Approved By (Document Responsible) Checked

CC&Q - EGS
Document Number Revision Date Reference

PA1 2020-10-07

----------------------------------------------

Version SPR2-CXP9060188_1-R13B156_9999-Release

Built on Sun May 24 06:08:13 CEST 2020

Copyright (C) 1998-2020, Ericsson AB. All rights reserved.

p01: alternate

--------------

Version SPR2-CXP9060188_1-R6B107_9999-Release

Built on Thu Aug 23 05:59:46 CEST 2018

Copyright (C) 1998-2018, Ericsson AB. All rights reserved.

[local]SPCL11#save configuration

Save to file: /flash/ericsson.cfg

Target file exists, overwrite? (y/n) y

NESTE EXEMPLO, DEIXAMOS A PARTIÇÃO “p01” COMO “ALTERNATE” COM A VERSÃO DE SW ANTERIOR
POR QUESTÕES DE SEGURANÇA.

CASO QUEIRA DEIXAR AS 2 PARTIÇÕES COM A MESMA VERSÃO DE SW, FAÇA NOVAMENTE O
PROCEDIMENTO.