You are on page 1of 10

Parameters

6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

0 Passw. control page 0 N/A N/A N/A N/A


0 Passw. language page 0 N/A N/A N/A N/A
0 Passw. log page 0 N/A N/A N/A N/A
0 GSM Pin code 1933 N/A N/A N/A N/A
0 12345678905 N/A N/A N/A N/A OFF N/A 
0 12345678904 N/A N/A N/A N/A OFF N/A 
0 12345678903 N/A N/A N/A N/A OFF N/A 
0 12345678903 N/A N/A N/A N/A OFF N/A 
0 12345678903 N/A N/A N/A N/A OFF N/A 
0 Cmd. 8 Min 0 N/A N/A N/A N/A
0 Cmd. 8 Hour 10 N/A N/A N/A N/A
0 Cmd. 8 Day(s) 10 N/A N/A N/A N/A
0 Start/Stop Cmd8 1 N/A N/A N/A OFF N/A
0 Cmd. 7 Min 0 N/A N/A N/A N/A
0 Cmd. 7 Hour 10 N/A N/A N/A N/A
0 Cmd. 7 Day(s) 10 N/A N/A N/A N/A
0 Start/Stop Cmd7 1 N/A N/A N/A OFF N/A
0 Cmd. 6 Min 0 N/A N/A N/A N/A
0 Cmd. 6 Hour 10 N/A N/A N/A N/A
0 Cmd. 6 Day(s) 10 N/A N/A N/A N/A
0 Start/Stop Cmd6 1 N/A N/A N/A OFF N/A
0 Cmd. 5 Min 0 N/A N/A N/A N/A
0 Cmd. 5 Hour 10 N/A N/A N/A N/A
0 Cmd. 5 Day(s) 10 N/A N/A N/A N/A
0 Start/Stop Cmd5 1 N/A N/A N/A OFF N/A
0 Cmd. 4 Min 0 N/A N/A N/A N/A
0 Cmd. 4 Hour 10 N/A N/A N/A N/A
0 Cmd. 4 Day(s) 10 N/A N/A N/A N/A
0 Start/Stop Cmd4 1 N/A N/A N/A OFF N/A
0 Cmd. 3 Min 0 N/A N/A N/A N/A
0 Cmd. 3 Hour 10 N/A N/A N/A N/A
0 Cmd. 3 Day(s) 10 N/A N/A N/A N/A
0 Start/Stop Cmd3 1 N/A N/A N/A OFF N/A
0 Cmd. 2 Min 0 N/A N/A N/A N/A
0 Cmd. 2 Hour 10 N/A N/A N/A N/A
0 Cmd. 2 Day(s) 10 N/A N/A N/A N/A
0 Start/Stop Cmd2 1 N/A N/A N/A OFF N/A
0 Cmd. 1 Min 0 N/A N/A N/A N/A
0 Cmd. 1 Hour 10 N/A N/A N/A N/A
0 Cmd. 1 Day(s) 10 N/A N/A N/A N/A

Device: multi-line2 AGC 2 (2.11.0)


Page 1
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

0 Start/Stop Cmd1 1 N/A N/A N/A OFF N/A


1010 Reverse power -5 % 10 0 0 ON Trip of GB
1020 Over current 1 115 % 10 0 0 ON Warning
1030 Over current 2 120 % 5 0 0 ON Trip of GB
1070 Fast Overcurr.1 150 % 2 0 0 ON Warning
1080 Fast Overcurr.2 200 % 0,5 0 0 ON Trip of GB
1100 Gen high-volt 1 110 % 10 0 0 ON Warning
1110 Gen high-volt 2 115 % 5 0 0 ON Shutdown
1120 Gen low-volt 1 97 % 10 0 0 RUN Warning
1130 Gen low-volt 2 95 % 5 0 0 RUN Shutdown
1140 Gen high-freq 1 105 % 10 0 0 ON Warning
1150 Gen high-freq 2 107 % 5 0 0 ON Shutdown
1160 Gen low-freq 1 97 % 10 0 0 RUN Warning
1170 Gen low-freq 2 95 % 5 0 0 RUN Shutdown
1180 BUS high-volt 1 103 % 10 0 0 OFF Warning
1190 BUS high-volt 2 105 % 5 0 0 OFF Warning
1200 BUS low-volt 1 97 % 10 0 0 OFF Warning
1210 BUS low-volt 2 95 % 5 0 0 OFF Warning
1220 BUS high-freq 1 105 % 10 0 0 OFF Warning
1230 BUS high-freq 2 107 % 5 0 0 OFF Warning
1240 BUS low-freq 1 97 % 10 0 0 OFF Warning
1250 BUS low-freq 2 95 % 5 0 0 OFF Warning
1260 Over load 1 100 % 10 0 0 ON Warning
1270 Over load 2 110 % 5 0 0 ON Trip of GB
1280 Unbalance curr. 30 % 10 0 0 ON Trip of GB
1290 Unbalance volt. 10 % 10 0 0 ON Trip of GB
1300 var import 40 % 10 0 0 ON Trip of GB
1310 var export 45 % 10 0 0 ON Trip of GB
1350 df/dt (ROCOF) 3 Hz/s N/A 0 0 ON Trip of GB
1351 df/dt (ROCOF) 6 Per N/A N/A N/A N/A
1360 Vector jump 5 deg N/A 0 0 ON Trip of GB
1580 Radiator Fans failed N/A 1 N/A N/A ON Shutdown
1590 Ventil. fan Failed N/A 1 N/A N/A OFF Warning
1600 Outlet louvers fail N/A 1 N/A N/A ON Warning
1611 Prelube pump ON time N/A 300 N/A N/A N/A
1612 Prelub pump OFF time N/A 7200 N/A N/A N/A
1620 Prelube pump failure N/A 1 N/A N/A ON Warning
1630 Air Compressor Fail N/A 1 N/A N/A ON Warning
1640 Backup Genset Fail N/A 1 N/A N/A OFF Warning
1640 Backup Genset failur N/A 1 N/A N/A OFF N/A

Device: multi-line2 AGC 2 (2.11.0)


Page 2
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

1651 Fuel Pump On N/A 1 N/A N/A ON Shutdown


1652 Elec. Fuel Pump Fail N/A 1 N/A N/A ON Shutdown
1660 IC Pump Failure N/A 1 N/A N/A ON Shutdown
1671 Safety timer 1 N/A 5 N/A N/A N/A
1672 Safety timer 2 N/A 5 N/A N/A N/A
1673 Warm up timer N/A 5 N/A N/A N/A
1674 Safety timer 3 N/A 5 N/A N/A N/A
1675 Fans start del N/A 10 N/A N/A N/A
1676 IC W. lev Sensor err N/A N/A N/A N/A OFF N/A
1676 Low IC water level N/A N/A N/A N/A ON Warning
1676 Water lev Sensor err N/A N/A N/A N/A OFF N/A
1676 Low cool water level N/A N/A N/A N/A ON Warning
1680 Crank Air P. 1 2 20 N/A N/A OFF Shutdown
1690 Crank Air P. 2 10 20 N/A N/A OFF Shutdown
1700 Manifol Air T.1 77 20 N/A N/A OFF Warning
1710 Manifol Air T.2 105 20 N/A N/A OFF Shutdown
1720 Lube Oil Temp 1 88 20 N/A N/A OFF Warning
1730 Lube Oil Temp 2 99 20 N/A N/A OFF Trip and stop
1740 Lube Oil Pres 1 100 20 N/A N/A OFF Warning
1750 Lube Oil Pres 2 75 20 N/A N/A OFF Shutdown
1760 Coolant Temp. 1 93 20 N/A N/A OFF Warning
1770 Coolant Temp. 2 99 20 N/A N/A OFF Trip and stop
1780 Coolant Press.1 25 20 N/A N/A OFF Warning
1790 Coolant Press.2 10 20 N/A N/A OFF Shutdown
1810 Radiator Door N/A 10 N/A N/A OFF Warning 
1820 Intake AirPres1 N/A 10 N/A N/A OFF Warning 
1830 Intake AirPres2 N/A 10 N/A N/A OFF Warning 
1840 Gen Air Filters N/A 10 N/A N/A OFF Warning 
1850 Lube Oil press N/A 10 N/A N/A OFF Warning 
1860 Fuel Oil press N/A 10 N/A N/A OFF Warning 
1870 low Volt Genera N/A 10 N/A N/A OFF Warning 
1880 Over Voltage N/A 10 N/A N/A OFF Warning 
1890 Over Frequency N/A 10 N/A N/A OFF Warning 
1900 Under Frequency N/A 10 N/A N/A OFF Warning 
1910 Neg Ph Seq curr N/A 10 N/A N/A OFF Warning 
1920 Reverse Power N/A 10 N/A N/A OFF Warning 
1930 Rev Reactive P N/A 10 N/A N/A OFF Warning 
1940 Neg Ph Seq Volt N/A 10 N/A N/A OFF Warning 
1950 Instan Overcurr N/A 10 N/A N/A OFF Warning 
1960 Timed Overcurr. N/A 10 N/A N/A OFF Warning 
Device: multi-line2 AGC 2 (2.11.0)
Page 3
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

1970 Ground Fault N/A 10 N/A N/A OFF Warning 


1980 Three Ph Diff. N/A 10 N/A N/A OFF Warning 
1990 Aux Gen Fail N/A 10 N/A N/A OFF Warning 
2011 Static sync N/A N/A N/A N/A OFF N/A
2021 Sync. dfMax 0,3 Hz N/A N/A N/A N/A
2022 Sync. dfMin 0 Hz N/A N/A N/A N/A
2023 Sync. dUMax 3% N/A N/A N/A N/A
2024 Sync. t GB 50 ms N/A N/A N/A N/A
2025 Sync. t MB 50 ms N/A N/A N/A N/A
2031 Static sync df max 0,1 Hz N/A N/A N/A N/A
2032 Static sync dU max 5% N/A N/A N/A N/A
2033 Static close window 10 deg N/A N/A N/A N/A
2034 Static phase Kp 10 N/A N/A N/A N/A
2035 Static phase KI 10 N/A N/A N/A N/A
2041 Blackout dfMax 3 Hz N/A N/A N/A N/A
2042 Blackout dUMax 3% N/A N/A N/A N/A
2070 GB General failure N/A 60 0 0 N/A
2080 MB General failure N/A 60 0 0 N/A
2091 MB Open failure N/A N/A N/A N/A Warning
2092 MB Close failure N/A N/A N/A N/A Warning
2093 GB Open failure N/A 5 N/A N/A Warning
2094 GB Close failure N/A 5 N/A N/A Warning
2100 Cylinder T. 1_1 660 °C 10 N/A N/A ON Alarm
2110 Cylinder T. 1_2 670 °C 10 N/A N/A ON Shutdown
2120 Cylinder T. 2_1 660 °C 10 N/A N/A ON Alarm
2130 Cylinder T. 2_2 670 °C 10 N/A N/A ON Shutdown
2140 Cylinder T. 3_1 660 °C 10 N/A N/A ON Alarm
2150 Cylinder T. 3_2 670 °C 10 N/A N/A ON Shutdown
2160 Cylinder T. 4_1 660 °C 10 N/A N/A ON Alarm
2170 Cylinder T. 4_2 670 °C 10 N/A N/A ON Shutdown
2180 Cylinder T. 5_1 660 °C 10 N/A N/A ON Alarm
2190 Cylinder T. 5_2 670 °C 10 N/A N/A ON Shutdown
2200 Cylinder T. 6_1 660 °C 10 N/A N/A ON Alarm
2210 Cylinder T. 6_2 670 °C 10 N/A N/A ON Shutdown
2220 Cylinder T. 7_1 660 °C 10 N/A N/A ON Alarm
2230 Cylinder T. 7_2 670 °C 10 N/A N/A ON Shutdown
2240 Cylinder T. 8_1 660 °C 10 N/A N/A ON Alarm
2250 Cylinder T. 8_2 670 °C 10 N/A N/A ON Shutdown
2260 Cylinder T. 9_1 660 °C 10 N/A N/A ON Alarm
2270 Cylinder T. 9_2 670 °C 10 N/A N/A ON Shutdown

Device: multi-line2 AGC 2 (2.11.0)


Page 4
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

2280 Cylinder T.10_1 660 °C 10 N/A N/A ON Alarm


2290 Cylinder T.10_2 670 °C 10 N/A N/A ON Shutdown
2300 Cylinder T.11_1 660 °C 10 N/A N/A ON Alarm
2310 Cylinder T.11_2 670 °C 10 N/A N/A ON Shutdown
2320 Cylinder T.12_1 660 °C 10 N/A N/A ON Alarm
2330 Cylinder T.12_2 670 °C 10 N/A N/A ON Shutdown
2340 Cylinder T.13_1 660 °C 10 N/A N/A ON Alarm
2350 Cylinder T.13_2 670 °C 10 N/A N/A ON Shutdown
2360 Cylinder T.14_1 660 °C 10 N/A N/A ON Alarm
2370 Cylinder T.14_2 670 °C 10 N/A N/A ON Shutdown
2380 Cylinder T.15_1 660 °C 10 N/A N/A ON Alarm
2390 Cylinder T.15_2 670 °C 10 N/A N/A ON Shutdown
2400 Cylinder T.16_1 660 °C 10 N/A N/A ON Alarm
2410 Cylinder T.16_2 670 °C 10 N/A N/A ON Shutdown
2420 Exhaust T. 1_1 660 °C 10 N/A N/A ON Alarm
2430 Exhaust T. 1_2 670 °C 10 N/A N/A ON Shutdown
2440 Exhaust T. 2_1 660 °C 10 N/A N/A ON Alarm
2450 Exhaust T. 2_2 670 °C 10 N/A N/A ON Shutdown
2460 Spare Termo 1_1 520 °C 10 N/A N/A OFF Alarm
2470 Spare Termo 1_2 520 °C 10 N/A N/A OFF Shutdown
2480 Spare Termo 2_1 520 °C 10 N/A N/A OFF Alarm
2490 Spare Termo 2_2 520 °C 10 N/A N/A OFF Shutdown
2511 Freq. Control DB 1% N/A N/A N/A N/A
2512 Freq. Control Kp 50 N/A N/A N/A N/A
2513 Freq. Control Ki 10 N/A N/A N/A N/A
2521 Power Control DB 1% N/A N/A N/A N/A
2522 Power Control Kp 30 N/A N/A N/A N/A
2523 Power Control Ki 30 N/A N/A N/A N/A
2531 Power ramp up speed 20 %/s N/A N/A N/A N/A
2532 Power ramp up point 0,08 s 2 N/A N/A N/A
2541 Power ramp down 20 %/s N/A N/A N/A Warning
2542 Power ramp d. point 5% N/A N/A N/A N/A
2550 Analogue GOV Offset 0 N/A N/A N/A N/A
2560 GOV reg. fail 30 % 60 0 0 N/A
2581 Volt Control DB 1% N/A N/A N/A N/A
2582 Volt Control Kp 20 N/A N/A N/A N/A
2583 Volt Control Ki 50 N/A N/A N/A N/A
2591 Var Control DB 1% N/A N/A N/A N/A
2592 Var Control Kp 25 N/A N/A N/A N/A
2593 Var Control Ki 78 N/A N/A N/A N/A

Device: multi-line2 AGC 2 (2.11.0)


Page 5
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

2600 Analogue AVR Offset 0 N/A N/A N/A N/A


2610 AVR reg. fail 30 % 60 0 0 N/A
2690 Delay regulatio N/A s 0 0 0 N/A
2700 Short Parallel. 0 0,3 N/A N/A N/A
3060 EGU/SRLC FAULT N/A 0 0 0 RUN Shutdown 
3070 Dig. Input No44 N/A 10 0 0 OFF Warning 
3080 Dig. Input No45 N/A 10 0 0 OFF Warning 
3090 Dig. Input No46 N/A 10 0 0 OFF Warning 
3100 Dig. Input No47 N/A 10 0 0 OFF Warning 
3110 Dig. Input No48 N/A 10 0 0 OFF Warning 
3120 Dig. Input No49 N/A 10 0 0 OFF Warning 
3130 Dig. Input No50 N/A 10 0 0 OFF Warning 
3140 Dig. Input No51 N/A 10 0 0 OFF Shutdown 
3150 Dig. Input No52 N/A 3 0 0 ON Warning 
3160 Dig. Input No53 N/A 10 0 0 OFF Warning 
3170 Dig. Input No54 N/A 10 0 0 OFF Warning 
3180 GEN DIF/EF PROT N/A 10 0 0 ON Shutdown 
3190 Dig. Input No91 N/A 10 0 0 OFF Warning 
3200 Dig. Input No92 N/A 10 0 0 OFF Warning 
3210 Dig. Input No93 N/A 10 0 0 OFF Warning 
3220 Dig. Input No94 N/A 10 0 0 OFF Warning 
3230 Dig. Input No95 N/A 10 0 0 OFF Warning 
3240 Dig. Input No96 N/A 10 0 0 OFF Warning 
3250 Dig. Input No97 N/A 10 0 0 OFF Warning 
3300 Access lock N/A 0 0 0 OFF Warning 
3310 Run. feedback N/A 0 0 0 OFF Warning 
3320 Engine failure N/A 10 0 0 OFF Shutdown 
3330 Emergency STOP N/A 0 0 0 ON Shutdown 
3340 Dig. Input 118 N/A 10 0 0 OFF Warning 
4090 4-20mA No98.1 10 120 0 0 OFF Warning  
4100 4-20mA No98.2 10 120 0 0 OFF Warning  
4110 Prelube pump 1 10 5 N/A N/A OFF Warning  
4120 Prelube pump 2 10 5 0 0 OFF Warning  
4140 Fuel level 2 10 120 0 0 OFF Warning  
4150 Air tank pres.1 10 10 N/A N/A OFF Warning  
4160 Air tank pres.2 10 10 N/A N/A OFF Warning  
4240 Bear.temp 80 5 0 0 ON Shutdown 
4260 wind temp 120 5 0 0 ON Shutdown 
4301 Running detect. 1000 N/A N/A N/A N/A
4302 Running detect. type 1 N/A N/A N/A N/A

Device: multi-line2 AGC 2 (2.11.0)


Page 6
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

4310 Overspeed 1 1100 5 0 0 OFF Warning


4320 Overspeed 2 1150 1 0 0 OFF Shutdown
4340 W. fail ana 93 293 °F 10 N/A N/A OFF N/A  
4350 W. fail ana 95 329 °F 10 N/A N/A OFF N/A  
4360 W. fail ana 97 221 °F 10 N/A N/A OFF N/A  
4370 W. fail ana 98 230 °F 10 N/A N/A OFF N/A  
4370 W. fail ana 98 N/A N/A 0 0 OFF Warning
4380 W. fail ana 100 250 °F 10 N/A N/A OFF N/A  
4380 W. fail ana 100 N/A N/A 0 0 OFF Warning
4390 W. fail ana 102 250 °F 10 N/A N/A OFF N/A  
4390 W. fail ana 102 N/A N/A 0 0 OFF Warning
4400 W. fail ana 104 250 °F 10 N/A N/A OFF N/A  
4400 W. fail ana 104 N/A N/A 0 0 OFF Warning
4410 VDO104 W. fail max. 250 °F 10 N/A N/A OFF N/A  
4410 W. fail PT106 N/A % N/A 0 0 OFF Warning
4411 PT106 W. fail max. 100 % N/A N/A N/A N/A
4412 PT106 W. fail min. 0% N/A N/A N/A N/A
4420 VDO105 W. fail max. 10 bar 10 N/A N/A OFF N/A  
4420 W. fail PT109 N/A % N/A 0 0 OFF Warning
4421 PT109 W. fail max. 100 % N/A N/A N/A N/A
4422 PT109 W. fail min. 0% N/A N/A N/A N/A
5050 Relay 5 1 3 N/A N/A N/A
5060 Relay 6 0 5 N/A N/A N/A
5070 Relay 7 0 5 N/A N/A N/A
5080 Relay 8 0 5 N/A N/A N/A
6011 Nom. Frequency 50 Hz N/A N/A N/A N/A
6012 Nom. Power 2500 kW N/A N/A N/A N/A
6013 Nom. Current 190 A N/A N/A N/A N/A
6014 Nom. Voltage 10500 V N/A N/A N/A N/A
6031 Volt prim GEN 10500 V N/A N/A N/A N/A
6032 Volt sec GEN 105 V N/A N/A N/A N/A
6033 Current prim 250 A N/A N/A N/A N/A
6034 Current sec 5A N/A N/A N/A N/A
6041 Volt prim BUS 10500 V N/A N/A N/A N/A
6042 Volt sec BUS 105 V N/A N/A N/A N/A
6050 Engine Type N/A N/A N/A N/A N/A
6061 Gen-set Mode 1 N/A N/A N/A N/A
6081 Running Time 0 N/A N/A N/A OFF N/A
6082 GB Operations 0 N/A N/A N/A OFF N/A
6083 MB Operations 0 N/A N/A N/A OFF N/A

Device: multi-line2 AGC 2 (2.11.0)


Page 7
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

6084 Reset KWh Coun. N/A N/A N/A N/A OFF N/A
6085 Start att count 0 N/A N/A N/A N/A
6090 Service timer 500 N/A 0 0 OFF N/A
6110 Battery low V 18 V 1 0 0 ON N/A
6131 Language 0 N/A N/A N/A N/A
6141 Alarm Horn N/A s 20 N/A N/A N/A
6150 Run status N/A 60 0 0 OFF N/A
6161 Remove Starter 100 N/A N/A N/A N/A
6162 Number of Teeth 0 N/A N/A N/A N/A
6171 Start Prepare N/A 30 N/A N/A N/A
6172 Start On Time N/A 15 N/A N/A N/A
6173 Start Off Time N/A 5 N/A N/A N/A
6181 Start attempts 1 N/A 0 0 N/A
6184 Fire start att. 7 N/A 0 0 N/A
6191 f/U OK N/A 5 N/A N/A N/A
6201 f/U failure N/A 30 0 0 ON N/A
6211 Cooldown Time N/A 360 N/A N/A N/A
6212 Extended Stop Time N/A 5 N/A N/A N/A
6213 Coil type 1 N/A N/A N/A N/A
6220 Stop failure N/A 30 0 0 ON N/A
6251 GB Control N/A s 2 N/A N/A N/A
6261 Pnom derate 0 N/A N/A N/A OFF N/A
6262 Start derate at 16 N/A N/A N/A N/A
6263 Derate slope 50 N/A N/A N/A N/A
6266 Proportional 800 % N/A N/A N/A OFF N/A
6311 Idle start tim. N/A 18000 N/A N/A N/A
6312 Idle start tim. N/A N/A N/A N/A OFF N/A
6313 Idle stop tim. N/A 18000 N/A N/A N/A
6314 Idle stop tim. N/A N/A N/A N/A OFF N/A
6315 Idle active N/A N/A 0 0 OFF N/A
6380 Loadshare out 5V N/A N/A N/A N/A
6390 L. Sharing Type 0 N/A N/A N/A N/A
6400 Master clock 20 N/A N/A N/A OFF N/A
6401 Master clock 8 N/A N/A N/A N/A
6402 Master clock 8 N/A N/A N/A N/A
6404 Master clock 0,1 Hz N/A N/A N/A N/A
6410 Battery Test 18 V 20 0 0 ON N/A
6420 Voltage Trip 0 N/A N/A N/A N/A
6501 Day Setting 750 kW N/A N/A N/A N/A
6502 Night Setting 1000 kW N/A N/A N/A N/A

Device: multi-line2 AGC 2 (2.11.0)


Page 8
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

6503 Transducer Range 1500 kW N/A N/A N/A N/A


6504 Transducer Range -1500 kW N/A N/A N/A N/A
6511 Start Hour 8 N/A N/A N/A N/A
6512 Start Minute 0 N/A N/A N/A N/A
6513 Stop Hour 16 N/A N/A N/A N/A
6514 Stop Minute 0 N/A N/A N/A N/A
6521 Start Generator 80 % 10 N/A N/A N/A
6523 Minimum Load 5% N/A N/A N/A N/A
6531 Stop Generator 60 % 30 N/A N/A N/A
6541 Test 80 % 300 N/A N/A N/A
6543 Test Syncr. N/A N/A N/A N/A OFF N/A
6544 Return mode 1 N/A N/A N/A N/A
6551 Contr. settings P 70 % N/A N/A N/A N/A
6552 Contr. settings PF 0,9 N/A N/A N/A N/A
6591 Mains Fail. Delay U N/A 5 N/A N/A N/A
6592 Mains OK Delay U N/A s 60 N/A N/A N/A
6593 Low Voltage 90 % N/A N/A N/A N/A
6594 High Voltage 110 % N/A N/A N/A N/A
6601 Mains Fail. Delay f N/A 5 N/A N/A N/A
6602 Mains OK Delay f N/A 60 N/A N/A N/A
6603 Low Frequency 95 % N/A N/A N/A N/A
6604 High Frequncy 105 % N/A N/A N/A N/A
6611 Modeshift 0 N/A N/A N/A N/A
6612 MB Control N/A s 0,5 N/A N/A N/A
6613 Back Synchronising N/A N/A N/A N/A OFF N/A
7012 Ext. Comm.Speed 0 N/A N/A N/A N/A
7131 Int. Comm. ID N/A N/A N/A N/A N/A
7132 CAN fail mode 0 N/A N/A N/A N/A
7161 BH Note ID 1 N/A N/A N/A ON N/A
7162 CanIO Comm. Err N/A N/A N/A N/A N/A
7163 Ena Master Modb N/A N/A N/A N/A OFF N/A
7501 Load dep. start 100 kW 10 N/A N/A N/A
7503 Minimum Load 20 kW N/A N/A N/A N/A
7511 Load dep. stop 180 kW 30 N/A N/A N/A
7521 DG's available 1 N/A N/A N/A N/A
7522 Mains avail. N/A N/A N/A N/A OFF N/A
7523 PM Active N/A N/A N/A N/A OFF N/A
7524 Command unit N/A N/A N/A N/A ON N/A
7525 Start/stop 0 N/A N/A N/A N/A
7531 Priority select 0 N/A N/A N/A OFF N/A

Device: multi-line2 AGC 2 (2.11.0)


Page 9
Utility software (1.4.0.100)
Parameters
6551
26/05/2008 18:27:56

Config bits

Outputs
Channel Name Value Timer A B Enabled Fail class

7532 Nbr Multistart 1 N/A N/A N/A OFF N/A


7533 Min Nbr Running 1 N/A N/A N/A OFF N/A
7534 Ena Multistart N/A N/A N/A N/A OFF N/A
7541 Enable Mains N/A N/A N/A N/A OFF N/A
7542 Enable ID1 N/A N/A N/A N/A ON N/A
7543 Enable ID2 N/A N/A N/A N/A OFF N/A
7544 Enable ID3 N/A N/A N/A N/A OFF N/A
7545 Enable ID4 N/A N/A N/A N/A OFF N/A
7546 Enable ID5 N/A N/A N/A N/A OFF N/A
7551 Enable ID6 N/A N/A N/A N/A OFF N/A
7552 Enable ID7 N/A N/A N/A N/A OFF N/A
7553 Enable ID8 N/A N/A N/A N/A OFF N/A
7554 Enable ID9 N/A N/A N/A N/A OFF N/A
7555 Enable ID10 N/A N/A N/A N/A OFF N/A
7556 Enable ID11 N/A N/A N/A N/A OFF N/A
7561 Enable ID12 N/A N/A N/A N/A OFF N/A
7562 Enable ID13 N/A N/A N/A N/A OFF N/A
7563 Enable ID14 N/A N/A N/A N/A OFF N/A
7564 Enable ID15 N/A N/A N/A N/A OFF N/A
7565 Enable ID16 N/A N/A N/A N/A OFF N/A
7576 Transmit N/A N/A N/A N/A OFF N/A
7601 Prio. update hour 175 N/A N/A N/A N/A
7602 Run hour type 0 N/A N/A N/A N/A
7603 Reset re. count N/A N/A N/A N/A OFF N/A
7610 Ground relay N/A N/A 0 0 OFF N/A
7640 Stop noncon. DG N/A s 60 N/A N/A N/A
7671 Fuel Optimise 80 % N/A N/A N/A N/A
7672 Fuel Optimise 200 kW N/A N/A N/A N/A
7673 Fuel Optimise N/A s 10 N/A N/A N/A
7674 Fuel Optimise 175 N/A N/A N/A OFF N/A
9116 Customer Password ****** N/A N/A N/A OFF N/A
9117 Service Password ****** N/A N/A N/A N/A
9118 Master Password ****** N/A N/A N/A N/A

Device: multi-line2 AGC 2 (2.11.0)


Page 10
Utility software (1.4.0.100)