Single-phase

Portable Dewatering Pumps

LB/HS/NK
LSC/LSP

LB LB-A HS NK

LSC LSP

Printed on recycled paper with soy ink - Amenities from Technology


Evidence of our commitment to the environment for People and the Earth
Specification Table Common Features
Submersible Pump Anti-Wicking Cable Entry Oil Lifter (Patented)
Category
General Dewatering An anti-wicking block is The Oil Lifter was developed as a lubricating device for the
provided at the cable Cable mechanical seal. Utilizing the centrifugal force of the shaft
Series LB LB-1500 HS NK entry section of the motor seal, the Oil Lifter forcibly supplies lubricating oil to the
Molded upper seal faces even if the lubricant falls below the
Discharge Bore mm 50 (80) 50 (80) 50 · 80 (50) 50 chamber. Even if the
Cable
cable jacket becomes Boot
specified volume. This amazingly simple device reliably
Output kW 0.48 – 0.75 1.5 0.4 – 0.75 1.5 – 2.2
Motor damaged or the tip of lubricates and cools but also stabilizes the effect of the
No. of Poles 2 2 2 2 the cable is accidentally shaft seal and extends the length of the inspection period.
Gland
immersed in water, this
Flow-Thru ● ● (Limited
Top Discharge device prevents water Tightning
Discharge
Design
Side Flow ● from traveling into the Plate)
Side Discharge ● motor chamber through Oil Lifter
Anti-Wicking
capillary action. Guide Vane Mechanical
Impeller Block
Semi-vortex Semi-open Semi-vortex Semi-vortex Seal

Automatic Operation Electrode (LB-A) — Float (HSZ) —


High-Performance Motor
Page No. 3–4 5 6 7 Dry type, squirrel-cage induction
Oil Lifter
motor, housed in a watertight casing,
Submersible Pump Non-submersible Pump conforms to either insulation class B or
Category E. In both of these classes, all stand-
Residue Dewatering ard pumps can be used in ambient
Series LSC LSP temperatures up to 40°C. Guide Vane

Discharge Bore mm 25 25

Output kW 0.48 0.48 Automatic Motor Protection Device V-Ring


Motor A built-in thermal motor protection device reacts to the heat *Not Available on HS2.4S
No. of Poles 2 2
caused by overcurrent or run-dry conditions. It not only A V-ring is mounted at the top of the impeller and is brought
Flow-Thru ● ● cuts off the motor circuit automatically but also resets by in close contact to the bottom of the mechanical seal by the
Top Discharge itself. When the motor cools down to a safe operating
Discharge Side Flow internal pressure of the pump casing. This V-ring acts as a
Design temperature, the motor restarts. dust seal to prevent fine abrasive particles in the pumping
Side Discharge fluid from reaching the mechanical seal.
Impeller Semi-vortex Semi-vortex

Automatic Operation — —

Page No. 8 9

Miniature Thermal Protector Circle Thermal Protector

Selection Curves Dual Inside Mechanical Seal V-Ring


28 28 A dual inside mechanical seal, located in the oil chamber
together with the Oil Lifter, has two sealing faces made of
quality materials, including silicon carbide (SiC). The Semi-Vortex Design
advantages of this seal are two-fold; it eliminates spring *Not Available on LB-1500 series
failure caused by corrosion, abrasion or fouling, which can The “high-gap structure” used on the pump minimizes the
20 20 prevent the seal faces from closing properly, and prevents “impeller lock” that can occur when the pump sucks in a
Total Head (m)

Total Head (m)

NK loss of cooling to the lower seal faces during run-dry large amount of sand at once. This structure is highly
2-
22
NK

HS LB conditions, which causes the lower seal faces to fail. resistant to wear, and performance is largely unaffected
NK
2-

3. -1
22

75 2- 50 even if the impeller becomes worn.


LB S 15 0/
-8 0 NK
0 (A LB 2-
) LB 15
10 -1 10 -4
50 80
0 (A
)
HS

LB
LB

HS H
3.75
-4

2.
-80
S2
80

.4

0( A
4S

(A

S
S
)

0 0
0 0.1 0.2 0.3 0.4 0.5 0 0.1 0.2 0.3 0.4 0.5
Capacity (m 3/min) Capacity (m 3/min)

1 2
LB
General Dewatering Pumps
Light, Compact, Easy-to-Uses
Tsurumi Typical Portable Pumps,
Perfect for a Variety of Applications
■Performance Curves
20
S.S. 3000min–1
20
S.S. 3600min–1
■Applications
Draining at civil engineering and building sites
Draining storm water, groundwater, or puddles
Draining from basements or utility pits
Draining water from dewatering wells
■Major Standard Specifications 16 16

Discharge Bore mm 50(80)

Total Head (m)


Total Head (m)
12 LB
Motor Output kW 0.48 - 0.75 LB
12 -8
-8 00
Rain, Spring, Ground, 0 (A
Pumping Type of Fluid
Fluid
Sand Carrying Water
0(
A)
LB
)
■Standard Accessories
Coupling ............1pc.
8 LB 8 -4
Fluid Temperature 0 to 40°C -4 80 ● Hose
80 (A
Impeller Semi-vortex
(A
)
) ● Hose Band .................. 1pc.
4 4
Structure Shaft Seal Double Mechanical Seal (with Oil Lifter)
Bearing Double-shielded Ball Bearing
Impeller Urethane Rubber 0 0
Pump 0 0.1 0.2 0.3 0 0.1 0.2 0.3
Casing Synthetic Rubber 3
Capacity (m /min)
3
Capacity (m /min)
Materials Suction Cover Carbon Steel + Urethane Rubber
Automatic Version Outer Cover Carbon Steel
Shaft Seal Silicon Carbide
Type, Pole
Dry Type Submersible
Induction Motor, 2-pole
■Standard Specifications 50/60Hz
Discharge Motor Starting Cable Dimensions C.W.L.
Insulation Class E Model Phase Dry Weight mm mm
Bore Output Method Length
Single-phase/
Phase/Voltage mm kW kg m d A A1 B B1 D W1
110V, 220V, 230V, 240V
■Individual Features Starting Method Capacitor Run 50 LB-480 0.48 Single Capacitor Run 10.4 5 50 233 162 286 228 187 50
Flow-Thru Design Motor
Protection Device Miniature Thermal Protector/
An excellent cooling effect for (Built-in) Circle Thermal Protector 50 LB-480A 0.48 Single Capacitor Run 11.0 5 50 233 162 286 228 187 115
the motor can be achieved at Lubricant Turbine Oil (ISO VG32)
Frame Aluminium Alloy Die-casting 50(80) LB-800 0.75 Single Capacitor Run 13.2 5 50 230 160 337 283 187 50
low water levels. The top dis-
Materials Shaft 403 Stainless Steel
charge port enables the pump to Cable
50(80) LB-800A 0.75 Single Capacitor Run 13.8 5 50 230 160 337 283 187 170
PVC
be installed in narrow locations. ● 80 mm discharge available upon request ● Dry weight excluding cable

Multi-Directional Hose Coupling Simple Structure


Discharge can be converted to horizontal direction. The pump section can be disassembled and ■Dimensions ■Cross-Section
Notched bolt holes enable the hose coupling to be reassembled using a single 13-mm box wrench.
removed by merely loosening the cap nuts.
Electrode Auto Control Device (LB-A)
<LB> <LB-A> 1
32 68
Stable electrode-type sensor ON/OFF operation
A A
51 114
prevents dry running, saves power consumption,
A1 A1 52A 76
and extends operational life.
65 50
64 53
52B 55
36 56

D
Slimline Models 26 54
The non-automatic model has the overall dimension Electrode- 3 31 25
22
of 187 mm and can fit in a 200-mm (8" ) casing. Type Sensor 35 29
20 30

■Automatic Operation Repeats


21 71
Level Control Unit 23 22
d d

No. Description No. Description No. Description


1 Cabtyre Cable 31 Wearing Plate 54 Shaft
20 Pump Casing 32 Hose Coupling 55 Rotor
Start 21 Impeller 35 Oil Plug 56 Stator
Water
B

B
Level 22 Suction Cover 36 Lubricant 64 Motor Frame

B1
B1
23 Strainer Stand 50 Motor Bracket 65 Outer Cover

W1
C.W.L. 25 Mechanical Seal 51 Motor Head Cover 68 Handle
W1
26 V-ring 52A Upper Bearing 71 Shaft Sleeve
Electrodes submerged Water level falling. Pump continues Timer makes pump Water level reaches
29 Oil Casing 52B Lower Bearing 76 Capacitor
in water. Pump starts Electrodes emerged operation for 1 min. to stop operation. electrodes. Pump
operation. from water and timer restarts. C.W.L. : Continuous Running Water Level
30 Oil Lifter 53 Motor Protector 114 Relay Unit
starts.

3 4
LB-Series High-Head Type Pump Equipped with an Agitator and a Spiral Pump Heavy-Duty, High-Head Pumps for
LB-1500
General Dewatering Pump
Fits into an 8" Casing HS
General Dewatering Pumps
Casing, Sand, Solids, Debris are Pumped with
Minimal Wear and Clogging
NK
General Dewatering Pumps
Handling Abrasive Materials Found on
Construction Sites

■Major Standard Specifications ■Major Standard Specifications ■Major Standard Specifications


Discharge Bore mm 50(80) Discharge Bore mm 50 80(50) Discharge Bore mm 50
Motor Output kW 1.5 Motor Output kW 0.4 - 0.75 Motor Output kW 1.5 - 2.2
Rain, Spring, Ground, Rain, Spring, Ground, Rain, Spring, Ground,
Pumping Type of Fluid Pumping Type of Fluid Sand Carrying Water Pumping Type of Fluid Sand Carrying Water
Sand Carrying Water Fluid Fluid
Fluid
Fluid Temperature 0 to 40°C Fluid Temperature 0 to 40°C Fluid Temperature 0 to 40°C
Impeller Semi-open Impeller Semi-vortex Impeller Semi-vortex
Structure Shaft Seal Double Mechanical Seal (with Oil Lifter) Structure Shaft Seal Double Mechanical Seal (with Oil Lifter) Structure Shaft Seal Double Mechanical Seal (with Oil Lifter)
Bearing Double-shielded Ball Bearing Bearing Double-shielded Ball Bearing Bearing Double-shielded Ball Bearing
Pump
Pump Impeller High-chromium Cast Iron Pump Impeller Urethane Rubber Impeller Ductile Cast Iron
Casing Synthetic Rubber Gray Cast Iron/ Materials Casing Synthetic Rubber
Materials Materials Casing
Outer Cover Carbon Steel Ductile Cast Iron Shaft Seal Silicon Carbide
■Individual Features Shaft Seal Silicon Carbide ■Individual Features Shaft Seal Silicon Carbide ■Individual Features Type, Pole
Dry Type Submersible
Flow-Thru Design Dry Type Submersible Spiral Design Type, Pole
Dry Type Submersible Side Flow Design Induction Motor, 2-pole
Type, Pole Induction Motor, 2-pole
An excellent cooling effect for the motor Induction Motor, 2-pole The large channel in the spiral casing Achieved efficient cooling of the Insulation Class B
Insulation Class B Insulation Class E motor. The top discharge port Single-phase/
can be achieved at low water levels. The allows sand and slit-laden water to Phase/Voltage
Single-phase/ Single-phase/ makes the pump easier to install 110V, 220V, 230V, 240V
top discharge port enables the pump to Phase/Voltage pass through efficiently. Phase/Voltage
110V, 220V, 230V, 240V 110V, 220V, 230V, 240V Capacitor Start/
in narrow locations. Starting Method
be installed in narrow locations. Starting Method Capacitor Start Starting Method Capacitor Run Capacitor Start + Capacitor Run
Motor Motor Motor Protection Device
Protection Device Circle Thermal Protector Air Lock Prevention Protection Device Miniature Thermal Protector/ Circle Thermal Protector
(Built-in) (Built-in) Circle Thermal Protector Internal Starting Capacitor (Built-in)
Internal Starting Capacitor The shaft-mounted agitator prevents
Lubricant Turbine Oil (ISO VG32) Lubricant Turbine Oil (ISO VG32) A starting capacitor is built into the pump, Lubricant Turbine Oil (ISO VG32)
A starting capacitor is built into the pump, Frame Aluminium Alloy Die-casting
the “air lock” that tends to take place Frame Aluminium Alloy Die-casting Frame Aluminium Alloy Die-casting
despite of the high-performance motor.
despite of the high-performance motor. Materials Shaft 403 Stainless Steel on vortex pumps. Materials Shaft 403 Stainless Steel Materials Shaft 403 Stainless Steel
Cable Chloroprene Rubber Cable PVC Cable Chloroprene Rubber
Agitator Simple Structure
Slimline Models ● Three-phase model available upon request Simple Structure
The pump section can be disassembled and
The pump has the overall dimension of 187 mm and
■Applications
The pump section can be disassembled and reas- ■Applications reassembled using a single 13-mm box ■Applications
can fit in a 200-mm (8" ) casing, making it suitable for sembled using a single 13-mm box wrench. Draining at civil engineering or building sites Draining at civil engineering or building sites
Draining at civil engineering and building sites wrench.
dewatering wells. Draining storm water, groundwater, or puddles Draining storm water, groundwater, or puddles
Draining storm water, groundwater, or puddles Auto Operation with Float Switch (HSZ) Draining from basements or utility pits Draining from basements or utility pits
Simple Structure Draining from basements or utility pits The pump employs a float switch for
Draining water from dewatering wells
The pump section can be disassembled and reas- automatic operation to prevent dry ■Standard Accessories ■Standard Accessory
sembled using a single 13-mm box wrench. running and lower power consump- ● HoseCoupling.........1pc. Coupling............1pc.
■Standard Accessories tion. ● Hose Band ............ 1pc.
● Hose

● HoseCoupling..................1pc.
● Hose Band ..................... 1pc.

■Performance Curves ■Dimensions ■Performance Curves ■Dimensions ■Performance Curves ■Dimensions


S.S. 3000min–1 S.S. 3600min–1 S.S. 3000min–1 S.S. 3600min–1 S.S. 3000min–1 S.S. 3600min–1
22 22 20 20 28 28

D
D

20 20

D
16 16
A1 A1
16 16 A 20 20 A
A1
Total Head (m)
Total Head (m)

Total Head (m)

Total Head (m)


Total Head (m)
Total Head (m)
A NK
LB 12 HS 12 H 2- d
3.

NK
d 22

S3
12 LB 12
-1

NK

2-
NK

75

.7
-1
50

22
5 2-

5S
S
2-
0

15
15
00

8 HS 8 HS
8 8 2. 2. 10 10

4S
4S

H
d

B
H
4 4

B1
4 4
B

C.W.L.
B1

B
C.W.L.

W1
B1
0 0 0 0 0 0

W1
0 0.1 0.2 0.3 0.4 0.5 0 0.1 0.2 0.3 0.4 0.5 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0.4 0.5 0 0.1 0.2 0.3 0.4 0.5
3 3 3 3 3 3
Capacity (m /min) Capacity (m /min) C.W.L. Capacity (m /min) Capacity (m /min) Capacity (m /min) Capacity (m /min) C.W.L. : Continuous Running Water Level
C.W.L. : Continuous Running Water Level
W1

C.W.L. : Continuous Running Water Level


■Standard Specifications 50/60Hz ■Standard Specifications 50/60Hz
■Standard Specifications 50/60Hz Discharge
Bore
Model
Motor
Output
Phase
Starting
Dry Weight
Cable
Length
Dimensions
mm
C.W.L.
mm
Discharge
Bore
Model
Motor
Output
Phase
Starting
Dry Weight
Cable
Length
Dimensions
mm
C.W.L.
mm
Method Method
Discharge Motor Starting Cable Dimensions C.W.L.
Model Phase Dry Weight mm mm mm kW kg m d A A1 B B1 D H W1 mm kW kg m d A A1 B B1 D H W1
Bore Output Method Length
mm kW kg m d A A1 B B1 D H W1 50 HS2.4S 0.4 Single Capacitor Run 11.3 5 50 241 207 158 84 184 328 90 50 NK2-15 1.5 Single Capacitor Start 29 10 50 240 187 555 473 240 573 80
Capacitor Start
50(80) LB-1500 1.5 Single Capacitor Start 33 10 50 187 122 600 518 187 593 80 80(50) HS3.75S 0.75 Single Capacitor Run 19.6 5 80 285 233 217 109 184 388 90 50 NK2-22 2.2 Single +Capacitor Run 29 10 50 240 187 555 473 240 573 80
● 80 mm discharge available upon request ● Dry weight excluding cable ● 50 mm discharge available upon request. Note that smaller discharge may increase friction loss. ● Dry weight excluding cable ● Dry weight excluding cable

5 6 7
Residue Dewatering Pump that Can Residue Dewatering Pump that is
LSC
Residue Dewatering Pump
Pump Water Down to a Minimum Level
of 1 mm
LSP
Self-Priming Residue
Dewatering Pump
Incorporated a Novel Mechanism
of Reverse-Flow Prevention

■Major Standard Specifications ■Major Standard Specifications


Discharge Bore mm 25 Discharge Bore mm 25
Motor Output kW 0.48 Motor Output kW 0.48

Pumping Type of Fluid Residual Water, Puddles Pumping Type of Fluid Residual Water, Puddles
Fluid Fluid
Fluid Temperature 0 to 40°C Fluid Temperature 0 to 40°C
Impeller Semi-vortex Impeller Semi-vortex
Structure Shaft Seal Double Mechanical Seal (with Oil Lifter) Structure Shaft Seal Double Mechanical Seal (with Oil Lifter)
Bearing Double-shielded Ball Bearing Bearing Double-shielded Ball Bearing
■Individual Features Impeller Urethane Rubber ■Individual Features Impeller Urethane Rubber
Flow-Thru Design Pump Casing Synthetic Rubber Flow-Thru Design Pump Casing Synthetic Rubber
An excellent cooling effect for the motor can Suction Cover Carbon Steel + Urethane Rubber An excellent cooling effect for the motor can be achieved Suction Cover 304 Stainless Steel
Materials Materials
be achieved at low water levels. The top Bottom Plate Carbon Steel + Synthetic Rubber at low water levels. Bottom Plate Aluminium Alloy Die-casting + Synthetic Rubber
discharge port enables the pump to be Outer Cover Carbon Steel Outer Cover Carbon Steel
Low Water Draining Mechanism
installed in narrow locations. Shaft Seal Silicon Carbide Shaft Seal Silicon Carbide
Dry Type Submersible The pump is ideal for draining shallow Dry Type Submersible
Type, Pole Type, Pole
Low Water Draining Mechanism Induction Motor, 2-pole flooding and narrow spaces. The new Induction Motor, 2-pole
A unique structure Insulation Class E siphon breaker mechanism prevents the Insulation Class E
enables the pump to Phase/Voltage
Single-phase / reverse-flow of water once it is sucked in. Phase/Voltage
Single-phase/
110V, 220V, 230V, 240V 110V, 220V, 230V, 240V
drain water down to a
Starting Method Capacitor Run Free-Positioning Suction Attachment Starting Method Capacitor Run
minimum water level Motor Motor
Protection Device The suction attachment can be placed freely without the Protection Device
of 1 mm. A proprietary valve seat and newly (Built-in)
Miniature Thermal Protector
(Built-in)
Miniature Thermal Protector
need to move the pump.
developed swing valve prevent the reverse- Lubricant Turbine Oil (ISO VG32) Lubricant Turbine Oil (ISO VG32)
flow of water once it is sucked in. Frame Aluminium Alloy Die-casting Simple Structure Frame Aluminium Alloy Die-casting
Materials Shaft 403 Stainless Steel The pump section can be disassembled and reassem- Materials Shaft 403 Stainless Steel
Rubber Lining Base Plate
Cable PVC bled using a single 13-mm box wrench. Cable PVC
The base plate is provided with a rubber
lining to prevent scratching of floor surfaces.
■Applications ■Applications ■Dimensions
Multi-Directional Hose Coupling Ideal for complete drainage of flat surfaces Ideal for complete drainage of flat surfaces where a
Discharge can be converted to horizontal where a sump is not available. sump is not available.
direction. Notched bolt holes enable the hose Rooftops, parking lots, utility pits, basements, Rooftops, parking lots, utility pits, basements, plant

D
coupling to be removed by merely loosening the plant maintenance, pools maintenance, pools
cap nuts. A

Simple Structure ■Standard Accessories ■Standard Accessories Discharge Port

The pump section can be disassembled and ● HoseBand ................................................1pc. ● φ25 mm Hose Coupling with Union .......... 1set
reassembled using a single 13-mm box wrench. ●φ25 mm Hose Coupling with Union Hose Band ...... 1set
● Suction Hose with Union (5m) ................. 1set Suction Port

● Suction Attachment .............................. 1pc.

H
B
■Performance Curves ■Dimensions

B1
S.S. 3000min–1 S.S. 3600min–1
13 13

■Standard Specifications 50/60Hz


D

10 10 Suction & Motor Starting Max. Cable Dimensions


Discharge Model Phase Dry Weight
Total Head (m)

Total Head (m)

A1 Output Method Vacuum Length mm


LS LS
A
Bore
C1 C1 kW kPa(mmHg) m A B B1 D H
. 4S .4 mm kg
S d
25 LSP1.4S 0.48 Single Capacitor Run 73.3(550) 16.5 5 276 263 153 240 307
5 5
● Dry weight excluding cable
9
H
B

B1

We reserve the right to change the specifications and designs for improvement without prior notice.
0 0
0 0.1 0.2 0 0.1 0.2
3 3
Capacity (m /min) Capacity (m /min) C.W.L.
W1

Your Dealer
■Standard Specifications 50/60Hz C.W.L. : Continuous Running Water Level

Discharge Motor Starting Cable Dimensions C.W.L.


Model Phase Dry Weight mm mm
Bore Output Method Length
mm kW kg m d A A1 B B1 D H W1

25 LSC1.4S 0.48 Single Capacitor Run 12 5 25 196 169 316 258 196 316 1
● Dry weight excluding cable
CAT. IB101-C Printed in Japan