VA LV E

15
53.8
54.5

65

2
VA LV E

CR2 01 Wiring Diagram ( 2 wires control )


1, RD connect with positive, the BK connect with negative, the valve
Closed POWER
closed, the actuator automatically power off after in place , the RD
valve remains fully closed position Control
GND
Circuit SW
2, BK connect with positive, the RD connect with negative, the valve
BK Open
open, the actuator automatically power off after in place, the valve
M
remains fully open position .
Actuator Internal Chart Actuator External Chart
* Suitable Working Voltage: DC5V/DC12V/DC24V
* Exceeding the working voltage is forbidden

CR2 02 Wiring Diagram ( 2 wires control – Spring return in case of the power failure)
1, When SW is closed , the valve open. the actuator automatically Farah Capacitors
SW
power off after in place RD
POWER
2, When SW is open, the valve closed, the actuator automatically Control
Circuit
power off after in place GND
BK
* Suitable Working Voltage: AC/DC9-35V
* Exceeding the working voltage is forbidden M
Actuator Internal Chart Actuator External Chart

CR3 01 Wiring Diagram (3 wires control )


1, RD & GR connect with positive, BK connect with negative
2, When OPEN (RD) & SW connected, the valve open, the Open
RD SW
actuator automatically power off after in place, valve remains POWER
Control Closed
fully open position GR
Circuit GND
3, When CLOSE (GR) & SW connected, the valve closed, the BK
actuator automatically power off after in place, valve remains M
fully closed position Actuator Internal Chart Actuator External Chart
* Suitable Working Voltage: DC5V, DC12V, DC24V
* Exceeding the working voltage is forbidden

3
VA LV E

POWER
1, RD connect with positive, the BK & GR connect with negative RD
SW
2, SW CLOSED, the valve OPEN, the actuator automatically power off Control
GR
Circuit GND
after in place. BK
3, SW OPEN, the valve CLOSED, the actuator automatically power off M
after in place. Actuator Internal Chart Actuator External Chart

* Suitable Working Voltage: DC9V-35V


* Exceeding the working voltage is forbidden

POWER
RD
1, RD& GR connect with positive, the BK connect with negative
Control
GR
2, SW CLOSED, the valve OPEN, the actuator automatically power off Circuit SW
GND

after in place BK

M
3, SW OPEN, the valve CLOSED, the actuator automatically power off
Actuator Internal Chart Actuator External Chart
after in place.
* Suitable Working Voltage: AC/DC9-35V/AC110-230V
* Exceeding the working voltage is forbidden

CLS RD
RD BK
Control OLS
1, RD & GR connected with positive, and the BK connected with GR
Circuit
negative COM
BK
2, When RD & SW connected, the valve closed, the actuator M
Actuator External
Actuator Internal Chart
automatically power off after in place , remains fully closed position Chart

3, When GR & SW connected, the valve open, the actuator automatically power off after in place, remains fully
open position
* Suitable Working Voltage: DC5V, DC12V, DC24V, AC/DC9-35V
* Exceeding the working voltage is forbidden

1, RD connect with positive, GR connect with SW & positive Farah Capacitors


POWER
RD
2, BK connect with negative
Control
3, When the SW of GR closed, the valve closed, the actuator Circuit
GR
GND
SW
automatically power off after in place , remains fully closed position BK
4, When the SW of GR open, the valve open, the actuator M
automatically power off after in place , remains fully open position Actuator Internal Chart Actuator External Chart

* Suitable Working Voltage: DC5V/DC12V/DC24V


* Exceeding the working voltage is forbidden

Farah Capacitors
POWER
1, RD connect with positive, GR connect with SW & positive RD
2, BK connect with negative Control
GR
3, When the SW of GR closed, the valve open, the actuator automatically Circuit SW GND
BK
power off after in place , remains fully closed position
M
4, When the SW of GR open, the valve closed, the actuator automatically
Actuator Internal Chart Actuator External Chart
power off after in place , remains fully open position.
* Suitable Working Voltage: DC1 2 V
* Exceeding the working voltage is forbidden

4
VA LV E

CR4 01 WIRI G DI GR (4 WIR S CO TROL)


POWER
1, RD&BK are connected to the power, WT&YW are connected AC/DC RD

BK GND
to the controlled wiring.
SW
Control
WT
2, When the sw is closed, the valve open Circuit

3, When the sw is open, the valve closed YW

M
4, Suitable working voltage:AC110v-230V5, Actuator Internal Chart Actuator External Chart
5, Exceeding the working voltage is forbidden

CR5 01 WIRI G DI GR ( WITH F DB CK SIG L)


Closed POWER
1, RD connect with positive, the BK connect with negative, the Control
RD

Circuit SW GND
valve closed, the actuator automatically power off afterin place BK
M
2, BK connect with positive, the RD connect with negative, the Open

BL Full Open Signal


valve open, the actuator automatically power off after in place
LS.1
3, BL & WT are connect when the valve open fully, YW&WT are YW Full Closed Signal
LS.2
connect when the valve closed fully WT

* Suitable Working Voltage: DC12V,DC24V Actuator Internal Chart Actuator External Chart

* Exceeding the working voltage is forbidden

CR502 WIRI G DI GR ( 5 wires control , with feedback signal)


1, When SW is closed , the valve open. the actuator automatically
power off after in place Farah Capacitors SW
POWER
RD
2, When SW is open, the valve closed, the actuator automatically Control
Circuit GND
power off after in place BL & WT are connect when the valve BK
M
open fully, YW & WT are connect when the valve cl osed fully
BL Full Open Signal
* Suitable Working Voltage: AC/DC9-24V, AC/DC110V-230V, LS.1
YW Full Closed Signal
* Exceeding the working voltage is forbidden LS.2
WT

Actuator Internal Chart Actuator External Chart

CR7 01 WIRI G DI GR ( 7 WIR S CO TROL WITH F DB CK SIG L)


1, RD connect with positive
2, GR connect with SW and negative wiring
RD POWER
3, BK connect with negative wiring Control
SW
GR
Circuit
5, SW closed. the valve closed, and keeping fully closed. BK
GND

M
6, BL & GY connect with the valve’s fully open signal wiring BL
Full Open Signal
7, YW & WT connect with the valve’s fully closed signal wiring. LS.1 GY

* Suitable Working Voltage: DC9V-35V LS.2 YW


Full Closed Signal
* Exceeding the working voltage is forbidden WT
Actuator Internal Chart Actuator External Chart
* Feedback with load ability
①The Max. off voltage: DC36V AC220V
②The Max. off current: 0.4A

5
VA LV E

CR7 02 Wiring Diagram ( 7 wires control with feedback signal )


Open
1.RD & GR connect with positive, the BK connect with negative RD SW
POWER
Closed
2. When RD & SW connected, the valve open, the actuator Control
Circuit
GR
GND
automatically power off after the valve fully open. BK
M
3. When GR & SW connected, the valve closed, the actuator BL
Full Open Signal
automatically power off after the valve fully closed. LS.1 GY

4. BL & GY connect with the valve’s fully open signal wiring LS.2 YW
Full Closed Signal
5. YW & WT connect with the valve’s fully closed signal wiring WT
Actuator Internal Chart
* Suitable Working Voltage:DC5V, DC12V, DC24V, AC/DC9-35V Actuator External Chart

* Exceeding the working voltage is forbidden


* Feedback with load ability
①The Max. off voltage: DC36V AC220V ②The Max. off current: 0.4A

RD POWER
SW
1, RD& GR connect with positive, the BK connect with negative Control
GR
Circuit GND
2, SW CLOSED, the valve OPEN, the actuator automatically BK
M
power off after in place BL
Full Open Signal
3, SW OPEN, the valve CLOSED, the actuator automatically LS.1 GY

power off after in place LS.2 YW


Full Closed Signal
4, BL & GY connect with the valve’s fully open signal wiring WT
5, YW & WT connect with the valve’s fully closed signal wiring. Actuator Internal Chart Actuator External Chart

* Suitable Working Voltage: DC12V, DC24V


* Exceeding the working voltage is forbidden

CR7 04 Wiring Diagram ( 7 wires control with feedback signal )


1, RD & BK are connected to the power, WT & YW are connected
AC/DC RD POWER
to the controlled wiring.
BK GND
2, When the SW is closed , the valve open Control
GY
Circuit SW
3, When the SW is open , the valve closed GR
4, BL & GY connect with the valve’s fully open signal wiring M
BL Full Open Signal
5, YW & WT connect with the valve’s fully closed signal wiring. LS.1

* Suitable Working Voltage: AC/DC110V-230V YW Full Closed Signal


LS.2
* Exceeding the working voltage is forbidden WT

Actuator Internal Chart Actuator External Chart

Manual override instructions:


In case of an electric supply failure, it is possible to operate the
actuator manually:
1, Power must in off position when start the manual override.
2, Gently pull up the knob about 3mm, then revolve the knob
around left and right to control the valve open or close.
3, When the red needle in the indicator pointing to S, means the
valve is closed. When pointing to 0, means the valve is open.
4, After finish the manual override operation, must press down
the knob, so that for the normal electric operation.