Displacement Sensor

LS series LS

CD5

2D Displacement Sensor CD4


A Revolution in Profile Measurement
CD33

Linearity ±0.1% of F.S.


CD3
Sampling period 0.5 ms (max. speed)
Superbly affordable 2D measurement CD22

CD1

Line beam provides high-speed,high-precision measurement of


height and width UQ1

Now you can perform whole-lot profile measure- Repeatability Resolution


ment on a range of production lines to ensure qual-
ity control of parts and materials. Offering superb Height (Z axis) 2 µm Width (X axis) 25 µm
high-speed performance and value for money, the
FASTUS LS series handles high-precision 2D mea- Linearity Sampling period

surement applications that are not possible with ±0.1% of F.S. Max. speed 0.5 ms
spotbeam laser displacement sensors. The LS
series is a newgeneration profile measurement Total sampling period 5 ms
sensor that opens up a new category in the field of
component measurement.

Proprietary system delivers high-speed, Comparison of Process Flow


*With 800 x 800 light receiving element

compact size, and low price Camera image (image data)


Employing a mathematical operation known as a
projection transformation, which converts a
captured image into distance, allows both height Competitor's LS series
system
and width to be measured with a high degree of
precision. Moreover, the use of a proprietary
method in which the projection transformation is Projection transformation
performed after triangulation— unlike competitors’ Triangulation
(640,000 points)
systems, which performs the projection transforma-
tion on every pixel—makes it possible to significantly
compress throughput and achieve high-speed mea-
Projection transformation
surement. The processing unit has also been kept Triangulation (800 points)
small, to produce a compact, low-cost product.

High speed

Projection Projection
transformation of transformation
original image after compression
Profile (distance data)

256
Displacement Sensor

LS
Measurement of brake pad Detection of double feeding of
component height boards
Measures the position Compared to previous
CD5
(height) of the end of the systems in which a displace-
pad wear indicator (PWI), a ment sensor was installed
CD4 metal part that indicates above and below the boards
brake wear, relative to the to measure thickness, a single
brake surface. LS series unit can measure
CD33 from the side, providing easy
installation and line design.

CD3

CD22

CD1

UQ1

Inspection of application Inspection of gap/level difference


position/amount of sealant between automobile doors
By measuring sealant width Provides quick, non-contact
and height directly after measurement of gap and level
application, feedback differences between door and
regarding the appropriate chassis to check precision of
amount and position can be automobile door installation.
provided immediately.

257
Displacement Sensor

Easy Setup LS
Imaging
The LS series can be configured in four easy steps: 01
imaging, profile, area measurement and calculation, The optimum shutter speed is set
CD5
and result judgment and output. automatically, just like a regular
camera.

CD4
Profile
02 A cross-sectional waveform (profile) is
created from the image. CD33
Correction is also possible.

CD3
Area measurement
03 Up to four areas can be set.
Measurement functions can be CD22
selected for each area.

CD1
Area calculation
Calculation settings can be
configured as necessary.
The operators that can be UQ1
used are + and -.

Result judgment and output


04
Output 1
Output 2 There are a total of four outputs: three
Output 3 control outputs and one analog output.
Analog output

Functions for Stable, High-precision Measurement


Auto function Profile correction function
Simply set the workpiece The LS series is equipped with a profile correction function
and click “Auto Adjust” to Auto Adjust that corrects the positional displacement of the workpiece
automatically select the relative to a registered master image in terms of height,
optimum shutter speed to position, and tilt. Profile
suit the amount of light
AUTO correction is effective on
received from the work- production lines where
piece. workpieces do not remain
still.

Four camera modes HDR mode NR mode


The LS series incorporates four camera (High Dynamic Range) (Noise Reduction)
modes for stable imaging: a standard, high
Ideal for workpieces with areas Without NR With NR
resolution mode; high speed mode, which of high contrast
captures images at four times the standard Metal surface: bright
speed; high dynamic range (HDR) mode,
which increases the range of brightness; and Black rubber: dark

noise reduction (NR) mode.


HDR mode creates a composite NR mode creates a composite
High resolution High speed image from two images taken image by amplifying an image of
with different shutter times. This the bright areas and combining it
HDR NR function is useful for workpieces with an image of the dark areas.
with areas of high contrast such This feature reduces noise such
as mirrored metal surfaces. as ambient light.

258
Displacement Sensor

LS
Diverse Range of Measurement Functions
Height Position
Allows measurement of average, peak, and bottom Allows measurement of peak, bottom, and edge
CD5
heights. positions.
The sensor outputs the average, maximum, and
CD4 minimum values for the profile within the area.
Bottom Peak Edge

CD33
Peak
Average

CD3 Bottom
Measurement
area
CD22 Measurement area

Width Edge count


CD1 Allows measurement of width of gaps and differ- Counts the number of times the profile crosses the
ences in level. center line of the area in the height direction.
The sensor detects the width of the profile at the This function can be used for applications such as
UQ1
center line of the area in the height direction. counting the number of pins.
12 3 4 5 6

Measurement Measurement
area area

Tilt (°) Size (mm2)


Creates a straight line approximating the profile, Calculates the area between the specified side of
and then measures the tilt of this line. (Unit: °) This the measurement area and the profile.
function measures and calculates the angle of both Selecting “↑” measures the cross-sectional area
sides of gaps and protrusions. of protrusions, while selecting “↓” measures the
cross-sectional area of concave sections.

Measurement area Measurement area

Length Diameter
Measures the length of the profile. Measures the diameter of the approximate
The value is the same even if the workpiece is curve determined from the measured values.
misaligned, so this function can be used without This function can be used to calculate the
position correction. diameter of cylinders,
protrusions, and gaps. R

Measurement area Measurement area

259
Displacement Sensor

Area calculation function provides a wider variety of measurement capabilities LS


Example of level difference measurement Example of angle measurement
By measuring the height of the upper and lower By measuring both angles of a feature in two
CD5
surfaces of a step in two measurement areas and measurement areas and subtracting one from the
subtracting one from the other, it is possible to other, it is possible to measure the angle.
measure the difference in level. This allows you to This lets you accurately measure the outer angle of CD4
ignore small areas of unevenness and variation, gaps and protrusions.
and enables more stable measurement compared
to a displacement sensor. CD33

CD3

CD22

Measurement area Measurement area


CD1

UQ1
Easily Configurable PC Software LS-Navigator (included as standard)

As standard, the LS series comes with software that lets you easily configure settings from a PC.

Easy configuration of capturing area and measurement area settings


All settings can be configured via RS-485 communication CD-ROM
Profiles can also be output with high precision included
No need for expensive purpose-built displays Software can also be
downloaded from
website.

Calculation settings Main screen Measurement screen


You can set up two calculation The main screen lets you check Settings screens are displayed as
formulas by choosing “Calc1” and measurement results and profiles. categories in the tabs on the left of
“Calc2”. You can also check hold and the screen.
trigger operation from this screen. Settings can be configured by
selecting these tabs in order from
top to bottom.

260
Displacement Sensor

LS
Measurement Range Dimensions
Beam range Emitter axis center
60 40
Receiver axis center 5.8
[Actual size]
CD5 2-ø4.2 Liquid-crystal
display
Tightening
torque:
0.7 N m Power indicator
or less
84.8 (green)

CD4 Laser emission


indicator
0 mm
94.5 (green)
67

CD33 46.5

6.2

4.5 External
CD3 communication
42.5 connector
11.6

CD22

25.8
18.05
CD1
32 mm Main cable
ø6 12 pins x 0.2 mm 2

UQ1
(mm)

17 mm 75 mm

I/O Circuit Diagram


Width of view
(Measurement range)
GND (blue) *PNP
12 to 24 VDC (brown) *NPN
Internal circuit

22 mm 100 mm
Inputs
* Selection of one of the below

Offset/stop laser emission (white)


Bank input 1/reset (purple)
Bank input 2/hold (orange)
Bank input 3/trigger (gray)
27 mm 125 mm
12 to 24 VDC (brown)
Internal circuit

Control OUT1 (yellow)


Beam projection range OUT2 (black)
output
OUT3 (red)
(NPN type)
0 V (blue)

Z Axis Material Linearity 0 V (blue)


Internal circuit

Control OUT1 (yellow)


OUT2 (black)
output
Aluminum Blue MC nylon Aluminum Nitrile rubber OUT3 (red)
(Al) (rolled) (PNP type)
0.2
12 to 24 VDC (brown)

0.15
Internal circuit

0.1

Analog
Linearity (% F.S.)

0.05
Analog output (white)
output
0

-0.05 Analog GND (shield)


3.3 V
-0.1
Internal circuit

-0.15 A(+) (orange)


RS-485
-0.2
75 80 85 90 95 100 105 110 115 120 125
B(-) (yellow)
Measurement distance (mm)
GND (black)
* All other cables are N.C. (No Contact).

261
Displacement Sensor

Options (Cables) LS
These cables are not included as standard. Purchase separately as needed.

CD5

CD4
Main cable PC connection cable (USB) RS-485 communication cable
(discrete wire)
Cable for power supply, I/O, and analog output. Connects sensor to PC when using PC software. Discrete wire cable for RS-485 communication.
RS-485-to-USB converter cable. CD33
z 2 m STL-0H12-G02M z 1.8 m DSL-DH06-G1M8 z 2 m DOL-SH06-G02M
z 5 m STL-0H12-G05M z 5 m DOL-SH06-G05M
z z
10 m STL-0H12-G10M 10 m DOL-SH06-G10M CD3
6SHFL¿cations: ø6 12 pins x 0.2 mm2

CD22
Specifications
Model LS-100CN CD1
Measurement range 100 ± 25 mm
Width of view (at measuring distance) 17 mm (at 75 mm) - 27 mm (at 125 mm)
Light source Red laser, wavelength: 655 nm, max. output: 1 mW
UQ1
Laser class IEC/JIS Class 2
FDA CLASS II
Spot size*1 0.3 × 32 mm
Linearity Z axis —эT— VM-:
Repeatability*2 Z axis эT
Resolution*3 X axis эT
Sampling period Typical value: 5 ms (when measuring the whole view in “Hi-res” mode), max. speed: 0.5 ms
Display Dot matrix display
Indicators Power indicator (green), laser emission indicator (green)
External input Selectable from bank, trigger, hold, reset, laser emission stop, and offset
Control output 3 NPN open collector outputs, max. 100 mA/30 VDC (max. residual voltage: 1.8 V)
Analog output [VT(V\[VMTLHZ\YLTLU[YHUNL!T(TH_SVHKPTWLKHUJL!£
Communication I/F RS-485 half duplex (9.6 kbps to 4.0 Mbps)
Temperature drift (typical example)  VM-:‡*
Power supply voltage [V=+*  PUJS\KPUNYPWWSL
Current consumption*4 Max. 180 mA
Protection category IP67
Ambient temperature/humidity [V‡*[V 9/UVJVUKLUZH[PVUVYMYLLaPUN
Storage temperature/humidity [V‡*[V 9/UVJVUKLUZH[PVUVYMYLLaPUN
Ambient illuminance Sunlight: 10000 lx or less, high-frequency lamp: 3000 lx or less
Vibration resistance [V/a"KV\ISLHTWSP[\KLTT"OV\YZPULHJOVM[OL?@HUKAKPYLJ[PVUZ
Shock resistance (WWYV_PTH[LS`.TZ[PTLZPULHJOVM[OL?@HUKAKPYLJ[PVUZ
Material /V\ZPUN!KPLJHZ[aPUJHUK7*SHZLYLTP[[LYHUKYLJLP]LYJV]LYZ!NSHZZ
Weight Approximately 300 g

PNP output model is LS-100CP.


*1 +LMPULK^P[OJLU[LYZ[YLUN[OL H[[OLJLU[LYVMTLHZ\YLTLU[YHUNL;OLZLUZVYTH`ILHMMLJ[LK^OLUSLHRSPNO[V[OLY[OHU[OH[VM[OLZWLJPMPLKZWV[ZPaLPZWYLZLU[HUK^OLU[OLYLPZ
a highly reflective object close to the detection area.
*2 Average height measurement of a white workpiece with a center width of 5 mm, smoothing performed 8 times, moving average performed 32 times (with the default settings)
*3 With a measurement distance of 75 mm
*4 Power supply voltage: 24 VDC not including the control output load current and including the analog output

Warnings
Never look directly into a laser beam or point a laser beam at another person’s eyes.
Doing so may cause eye damage and may be harmful to health.