238-4/Z-E/T-0891 238-4 UFD 7001 No Comments.

Kindly confirm flowrate and outlet temperature of EA-705


238-4/Z-E/T-0891 238-4 UFD 7002
(Ref to GPP Utility Summary)
Flowrates mismatch from GTC Tech Utility Consumption Rev.
238-4/Z-E/T-0891 238-4 UFD 7003
A.
238-4/Z-E/T-0891 238-4 UFD 7004 Please explain the clouded area
Plant air connection to K-701 A/B in 238-4-PFD-7002 not
238-4/Z-E/T-0891 238-4 UFD 7005
available.
238-4/Z-E/T-0891 238-4 UFD 7006 No Comments
238-4/Z-E/T-0891 238-4 UFD 7007 No Comments
238-4/Z-E/T-0891 238-4 UFD 7008 No Comments
238-4/Z-E/T-0891 238-4 UFD 8001 No Comments.
238-4/Z-E/T-0891 238-4 UFD 8002 Please confirm PFD of EA-827
Flowrates mismatch from GTC Tech Utility Consumption Rev.
A.
238-4/Z-E/T-0891 238-4 UFD 8003
Two MP headers shown (LP header mislabeled as MP
Header)
238-4/Z-E/T-0891 238-4 UFD 8004 Please explain the clouded area.
238-4/Z-E/T-0891 238-4 UFD 8005 No Comments.
238-4/Z-E/T-0891 238-4 UFD 8006 No Comments
238-4/Z-E/T-0891 238-4 UFD 8007 Please explain the clouded area.
238-4/Z-E/T-0891 238-4 UFD 9001 No Comments.
238-4/Z-E/T-0891 238-4 UFD 9002 No Comments.
238-4/Z-E/T-0891 238-4 UFD 9003 Please explain the clouded area.
238-4/Z-E/T-0891 238-4 UFD 9004 Please explain the clouded area.
238-4/Z-E/T-0891 238-4 UFD 9005 No Comments.
238-4/Z-E/T-0891 238-4 UFD 9006 No Comments.
238-4/Z-E/T-0891 238-4 UFD 9007 No Comments.
Please specify equipment tag of fuel gas K.O. drum.
238-4/Z-E/T-0891 238-4 UFD 9008
Please explain the clouded area.