You are on page 1of 3

Parameters Guide Words

No

Flow Rate Less

More

As well as

No

Pressure Less

More
Deviation Causes Consequences

No flow BLockage of pipe No Process run


Closed Valve Wastage of feed
Less flow Sightly blocked pipe Changed product composition
Half opened valve Incomplete absorption
Leakage of pipe
More flow Valve failure Changed product composition
Uncontrolled flow meter
Contamination Source exposed Corrosion
Pipe filled for the long time
No pressure change Compressor failure Less apsorption

Less pressure change BLockage of pipe Less absorption


Leakage of pipe Changed product composition
More pressure change Inappropriate function of valve, pump Damage column
Safeguards

Alarm installation
Bypass
Alarm installation
Regular inspection

Maintanence of valve
Install relief valve
Regular inspection

Regular inspection

Checking of valves

Check pump