FEATURES
■Simplified calibration and testing procedures for PT and CT circuits assure safety with their structure
Our test terminals allow you to perform calibration and that prevents wrong insertion.
testing procedures with instrument and relays connected ■High insulation and anti-inflammability
in place, resulting in great labor saving. For the housing material, high-performance engineering
■Broad range of applications plastics is used to provide high insulation,
Our test terminals are available in a broad range of types anti-inflammability, and impact resistance.
including the stud type and insertion type to meet your ■Special spec for tropical region
current capacity requirements ranging from 5 to 30A and To ensure high durability in harsh use under tropical
your applications. regions, special protective treatment is applied to some
■Safety structure products, which are available in the same ratings,
Our test terminals for CT circuits are designed to prevent performance, and dimensions as those of the standard
the circuit open. Both of the insertion type test terminals products.
Insulation resistance Insulation-resistance meter (1,000V DC) 1,000 MΩ Insulation-resistance meter (500V DC) 1,000 MΩ
∗ Operating current-carrying capacity as general termial use: 30 A (The rating varies depending on the conventional standard)
C219
CONNECTING DEVICES
HOW TO ORDER
A SWITCH
[B-type test terminal]
B-PTT B MR
Basic type Code Specification
Code Munsell color (blank) Standard
Code Structure / Usage 4/1.5 7.5BG4/1.5 MR Moisture resistance
PTT Single-contactor Structure 3/3.5 7.5BG3/3.5
CTT Dual-contactor Structure R 7.5R4.5/14
C Cover (Clear) Y
INDICATOR
SB Jumper
LB
K TT- A W 3-B M MR
B
Basic type
Code Specification
Test terminal Code Front cover (blank) Standard
(blank) Removal type MR Moisture resistance
M Slide type
Munsell color
CONNECTING
Code
4/1.5 7.5BG4/1.5
Code Contactor structure B N1.5
DEVICES
Code Specification S Single contactor
(Only for voltage type)
A For current W Dual contactor Code No. of poles Code No. of poles
V For voltage 1 1 pole (∗) 4 4 poles
2 2 poles 6 6 poles
3 3 poles 8 8 poles (∗)
C
[K-type test plug] (∗): Only for current type
K TP- A 3 MR
* There is no line up of 1 pole type
with the flont cover slide structure.
Basic type
Code Specification
(blank) Standard
MR Moisture resistance
ELECTRONIC
A TT- A 3
Basic type
Code No. of poles Code No. of poles
CENTER PARTS
TQ Test plug
(screw-type)
C220
E
●INSERTION TYPE
TEST TERMINALS
K-TYPE
STANDARD PRODUCTS (TERMINAL)
18
7 5 3 1
50
60
8 6 4 2
40
CTT
t=1.6∼6
81
A
Pin position
M4×10
●Applicable plugs
No. of poles 1 2 3 4 6 8 KTQ-A□
A 44 62 80 98 134 170 KTP-A□
18
7 5 3 1
50
60
8 6 4 2
40
VTT
t=1.6∼6
81
A
Pin position
M4×10
7 5 3 1
60
50
60
8 6 4 2
40
VTT
t=1.6∼6
81
A
Pin position
M4×10
C223
CONNECTING DEVICES
SLIDE COVER MODELS (TERMINAL)
A SWITCH
KTT-AW No. of poles
- Color (For current)
– Circuit open prevention type –
Terminal cover (clear) Terminal
t=1.6 to 6 No. NP
Slide cover up position
(70)
7 5 3 1
50
40
60
8 6 4 2
CTT
10
INDICATOR
M4×10
No. of poles 1 2 3 4 6 8
●Recommended plug type
KTQ-A□
A 44 62 80 98 134 170 KTP-A□
B
KTT-VW□-□M
No. of poles Color (For voltage)
CONNECTING
7 5 3 1
40
60
50
8 6 4 2
VTT
DEVICES
10
A 14 81
Plug mis-insertion
prevention pin
Slide cover Terminal cover (clear) M4×10
C
Pole
No. No.
of poles 2 3 4 6 ●Recommended plug type
KTQ-V□
A dimension
A 62 80 98 134
KTT-VS□-□M
No. of poles Color (For voltage)
DEVICES
(70)
7 5 3 1
60
40
50
8 6 4 2
VTT
10
A 14 81
D
Plug mis-insertion
prevention pin
Slide cover Terminal cover (clear) M4×10
C224
E
●INSERTION TYPE
TEST TERMINALS
K-TYPE
STANDARD PRODUCTS (PLUG)
mounted: 53.2)
22
10 10
60
22
18 18
L
69
●Applicable terminal
KTT-AW□
mounted: 53.2)
22
10 10
60
22
Jumper
L
69
●Applicable terminal
KTT-VS□
KTT-VW□ (Recommended)
10.
5
No. of poles 2 3 4 6
10
Short conductive portion on plug top L 62 80 98 134
mounted: 53.2)
22
10 10
60
22
18 18
L
5
66.
●Applicable terminal
KTT-AW□
10.
5
No. of poles 1 2 3 4 6 8
10
Long conductive portion on plug top L 44 62 80 98 134 170
mounted: 53.2)
22
10 10
60
22
Jumper
L
5
66.
●Applicable terminal
KTT-VS□
KTT-VW□ (Recommended)
10.
5
No. of poles 2 3 4 6
10
Long conductive portion on plug top L 62 80 98 134
C225
CONNECTING DEVICES
JUMPERS SUPPLIED WITH TEST PLUGS
A SWITCH
The quantities of jumpers supplied are shown as below:
Model KTP-A / KTQ-A KTP-V / KTQ-V
Pole 1P 2P 3P 4P 6P 8P 2P 3P 4P 6P
Jumper
KT jumper A ― 2 3 4 6 8 2 3 4 6
KT jumper B ― 1 2 3 5 7 ― ― ― ―
KT jumper A KT jumper B
(Vertical jumper) (Horizontal jumper)
INDICATOR
Plug case set
B
CONNECTING
■Box set for KTPB plugs Model Description ■Boset for KTQB plugs Model Description
KTP-A2 1 piece KTQ-A2 1 piece
DEVICES
KTPB-A2-V2 KTP-V2 1 piece KTQB-A2-V2 KTQ-V2 1 piece
Red, white wire 4 pieces each Red, white wire 4 pieces each
KTP-A3 1 piece KTQ-A3 1 piece
KTPB-A3-V3 KTP-V3 1 piece KTQB-A3-V3 KTQ-V3 1 piece
Red, white, blue wire 4 pieces each Red, white, blue wire 4 pieces each
KTP-A4 1 piece KTQ-A4 1 piece
KTPB-A4-V4 KTP-V4 1 piece KTQB-A4-V4 KTQ-V4 1 piece
Red, black, white, blue wire 4 pieces each Red, black, white, blue wire 4 pieces each
C
KTP-A6 1 piece KTQ-A6 1 piece
KTPB-A6 Red, white, blue wire 4 pieces each KTQB-A6 Red, white, blue wire 4 pieces each
Jumper
DEVICES
KT jumper A KT jumper B
D
29.5
●The material is single-side coated paper (white).
(Ordering unit: 100 pieces)
CONTROL
Type KT mark
C226
E
●INSERTION TYPE
TEST TERMINALS
K-TYPE
STRUCTURES AND EACH COMBINATION CHARACTERISTIC
Diagram of Main
Auxiliary contactor contactor Spring Upper terminal
Diagram of
Contactor Spring Upper terminal
contactor for current contactor for voltage
(KTT-AW□) (KTT-VS□)
When a plug is inserted and the auxiliary contactor is opened, When the plug is inserted, the contactor is opened. This
the main contactor will not be opened. The auxiliary contactor state will be maintained until the contactor makes contact
closes before the plug releases the main contactor. with the contact point of the plug. This eliminates the
Either the auxiliary contactor or the main contactor always possibility of making contact with the power source.
make circuit with a plug, preventing the CT circuit opening.
■Combination of KTT-AW and KTQ (Recommended) ■Combination of KTT-VS and KTP (Recommended)
The KTT-AW terminal has a dual-contactor structure The KTT-VS has a single-contactor structure consisting of a main contactor
consisting of main and auxiliary contactors. In addition, the only. The KTP has a long conductive part for contact up to 10 mm before its
KTQ plug has a long conductive part for contact up to its leading end (the leading 10 mm part is an insulator). When the plug is inserted,
leading end. Therefore, when the plug is inserted, the contact the contact (C) of the terminal is opened before the contact (B) is closed.
is completed at two contacts (A) and (B) before the contact Therefore, even if another power source is inserted from the plug when the
(C) of the terminal is opened. Thus, this combination provides plug is inserted or removed, there will be no possibility of making contact with
excellent function for preventing the circuit from being the power source. However, when the circuit voltage is measured with a test
opened. instrument, the relay will malfunction due to the momentary disconnection of
the circuit. For this reason, the relay must be locked.
To instrument or
power source for test To transformer
or instrument
To instrument or To transformer
power source for test or instrument
A B C
B C
■Combination of KTT-AW and KTP ■Combination of KTT-VS and KTQ (special combination)
The KTT-AW has a dual-contactor structure consisting of The KTT-VS has a single-contactor structure consisting of a main contactor
main and auxiliary contactors. The KTP plug has a shorter only. However, the KTQ has a long conductive part for contact up to its leading
conductive part for contact than the KTQ. However, when it is end. Therefore when the plug is inserted, the contact (B) of the terminal is
inserted, the contact (A) of the terminal is closed before the closed before the contact (C) is opened.
contact (C) is opened (the contact (B) starts being closed This ensures that the circuit never be opened when the plug is inserted or
after the contact (C) has been opened). removed. Therefore, when the circuit voltage is measured using a test
instrument, the relay will not malfunction due to the momentary disconnection
of the circuit. However, if you try to insert another power source from the plug,
a temporary connection with the power source will occur.
To transformer
To instrument or or instrument
power source for test
To transformer
To instrument or or instrument
A B C power source for test
B C
B
80
2
4
Size 1P 2P 3P 4P 6P 8P
A 36 54 72 90 126 162
A+50 A
B 44 62 80 98 134 170
A SWITCH
■Mounting procedure
●Terminal
cover
INDICATOR
(Take care so that the stoppers do not hit against any panel edge.)
B
OPERATING INSTRUCTIONS
■Measuring current and voltage
Voltage KT jumper A Current KT jumper A
1 5 3
3 1 5
CONNECTING
4
DEVICES
2 6
6
4 2
C
1. Short-circuit each phase (each set of the upper and lower 1. Connect an ammeter circuit between the poles to be
terminals represents the same phase) with the KT jumper measured.
A. 2. Short-circuit the other phases with the KT Jumper A.
2. Connect a voltmeter circuit between the phases to be 3. After the connection, insert the plug.
measured. Note: Opening the CT circuit creates a dangerous situation.
3. After the connection, insert the plug into the terminal. Be sure to avoid inserting the plug without ensuring the
Note: Be sure not to insert the plug with wrong phases proper connection.
short-circuited because it is dangerous to short-circuit Be sure to aroid inserting the plug with wrong
PT secondary circuit. The KT jumper B (for connection because it is dangerous to open CT circuit.
short-circuiting different phases) does not come with
the KTP-V and KTQ-V.
ELECTRONIC
DEVICES
Fuse Fuse
4 3
6 5
Meter or relay
D
Meter or relay
Connection diagram
Connection diagram
∗ When inserting the plug, take care not to touch with the
short bar or other.
CENTER PARTS
CONTROL
C228
E
●INSERTION TYPE
TEST TERMINALS
K-TYPE
■Calibrating a meter and testing a relay with the test power source
For voltage meter For current meter
(KTT-VS3
KTP-V3H ) (KTT-AW3
KTP-A 3 H)
Fuse Fuse
C.T
KT jumper B
∗ Note: Before connecting the power source for test, carefully check that it is connected to the correct terminals (not the vertically
reverse ones). To inset the plug, be sure to turn OFF the power switch.
Final block
∗ Note: Before inserting the plugs, short-circuit all the terminals
on the entire primary side of the current transformer
with the KT jumper B.
C229
CONNECTING DEVICES
WIRING INSTRUCTION
A SWITCH
Terminal: KTT-AW
Plug: KTP-A / KTQ-A
CT 1 unit Secondary output measurement CT 1 unit Current calibration
Circuit Connecting position Circuit Connecting position
∼
Jumper A
A
A A
INDICATOR
∼
3 4 4
CT CT 4
A
1 1 Outside 2
2
power supply
2 2
Jumper B
B
CT 2 units Secondary output measurement CT 2 units Current calibration
Circuit Connecting position Circuit Connecting position
A A ∼
CONNECTING
∼
SW SW A A
Terminal Plug 3 Terminal Plug Power SW
DEVICES
3
1 5 A
R S T 5 A R S T 5 1 5
6 6
4 ∼
∼ 4
3 A 3
2 6
4 4 2 6
A
1 1
C
A Outside
power supply
2 2
2xCT A A A 2xCT
Jumper B
Jumper A
A A ∼
∼
SW SW Power SW A A A
Terminal Plug Terminal Plug
3 7 3 7
7
D
7 1 5 1 5
8 8
RST RST A
5 A 5
4 8 ∼
∼
∼ 4 8
6 6
2 6 A 2 6
3 A 3
4 4
A
1 A 1
Outside
2 A A A 2 power supply Jumper B
3xCT 3xCT
CENTER PARTS
CONTROL
C230
E
●INSERTION TYPE
TEST TERMINALS
K-TYPE
WIRING INSTRUCTION
Jumper A ∼
V
V V
Terminal Plug 1 Terminal Plug Power SW 1
3 3
3 3
V ∼
4 2 4 2
V.T V.T
V 4 4
1 1 Outside
power supply
2 2
Jumper A
V ∼
V ∼
SW Terminal Plug V
SW Terminal Plug Power SW
1 5 V V
R S T 5 3 RST 5
V V 1 5
6 6
V ∼
∼
3 3 3
2xVT 6 2xVT
V 2 V
4 4
4 6
V 1 2
1 Outside
2 power supply 4
2
V V
Jumper A
V
V
∼
∼
SW
Terminal Plug SW Terminal Plug Power SW V
7 1 5 V
7
8 3 7 V V
V 8
RST 5 1 5
V RST 5
6 2 6 V ∼
∼
V 6 3 7
3xVT 3xVT
3 4 8 3
4 V 2 6
4
1 1 4 8
2 V Outside
2 power supply
V
C231
CONNECTING DEVICES
C232
CONTROL ELECTRONIC CONNECTING PILOT LAMP &
E D C B A SWITCH
CENTER PARTS DEVICES DEVICES INDICATOR