You are on page 1of 33

GROUNDING AND LIGHTNING

SPECIFICATION
Aluminium Air Terminal
Suitable for typical installation.

Rod Length Rod diameter Thread


Cat. No.
(mm.) (Ø) (mm.) (inch.)
T-LBAT-58-300A 300 15 5/8

T-LBAT-58-500A 500 15 5/8

T-LBAT-58-600A 600 15 5/8

T-LBAT-58-1000A 1000 15 5/8

T-LBAT-58-1500A 1500 15 5/8

T-LBAT-58-2000A 2000 15 5/8

T-LBAT-34-300A 300 19 3/4

T-LBAT-34-500A 500 19 3/4

T-LBAT-34-600A 600 19 3/4

T-LBAT-34-1000A 1000 19 3/4

T-LBAT-34-1500A 1500 19 3/4

T-LBAT-34-2000A 2000 19 3/4

* special Length size can be requested.


Material : Aluminium - BS 2898
Tested : IEC 62561-2

Aluminum Tape Saddle

Thread Max. Conductor


Cat. No.
Size (inch) Width (mm.)
T-LTS 58A 5/8 25

T-LTS 34A 3/4 25

Material : Copper Alloy - BS EN 1982

Aluminium Alloy - BS 2898


Tested : IEC 62561-1
�\\�u,,
�[3TOPWELD
'''"''
LIGHTNING PROTECTION & ACCESSORIES

Aluminium Adjustable Saddle


Thread Tape Size
Cat. No.
Size (inch) (mm.)
T-LAST 58-253A 5/8 25 x 3

T-LAST 58-254A 5/8 25 x 4

T-LAST 34-253A 3/4 25 x 3

Material : Aluminium Alloy - BS 2898


Tested : IEC 62561-1
For Tape Aluminum

Thread Tape Size


Cat. No.
Size (inch) (mm.)
T-LASC 58A 5/8 50-70

T-LASC 58-120A 5/8 95-120

Material : Aluminium Alloy - BS 2898


For Cable Aluminum Tested : IEC 62561-1
Steel Plate For Saddle Of Air Terminal

Support air terminal and saddle base


onto metal sheet roof. Air Terminal

Cable Conductor
Saddle for Air Terminal

Stainless Bolt Taper 1/4"x3/4" Stainless Bolt


M5x25 mm.

Support (Bakelite)

Diemension (mm)
Cat. No. For Saddle Metal Sheet Clamp
W L T
T-LSPS-BS525 For Adjustable Saddle 90 170 5 Steel Plate

Material : Hot Dip Galvanized Steel with Stainless Steel Bolt JP size M5x25 mm. T-BS525

Stainless Steel Bolt For Support


Cat. No. Type/Size

Stainless Steel Bolt Taper


T-BS26
Head size 1/4" x 3/4"

Support (Bakelite)
Support equipment as an insulator.

Cat. No. Color

T-LSB Black

Material : Bakelite
Metal Sheet Clamp (Can supply one complete set)
TOPWELD , we realize to design , material selection, galvanic corrosion avoidance, accurate
production, practically installation and architectural harmony.
Production
- No effect to roof structure
- No galvanic corrosion
- Effective cost
- Special Type can be request
- Customer can send example of roof to our factory
- Easy to Installation (Supply one set)
Supply Typical Detail

Material
1 304 stainless steel has excellent resistance to a wide range
of atmospheric environments and many corrosive media.
It is subject to pitting and crevice corrosion in warm
chloride environments and to stress corrosion cracking
above about 60 °C. It is considered resistant to potable
water with up to about 200 mg/L chlorides at ambient
2 temperatures, reducing to about 150 mg/L at 60 °C.

Quantity
Item Description
3 /Set
1 Bolt for Cable Support ,Brass 2

4 2
Stainless Steel Bolt Taper Head
Size ¼’’ x ¾’’
1

3 Stainless Steel Bolt JP M5 x 25 mm. 2

5 4 Bakelite Support 1

5 Nut ¼’’ in Insulator 1

6 6 Metal Sheet Clamp 1


Metal Sheet Clamp
Hold copper stranded or tape conductors
to metal roof.

Cat. No. Material

T-LMSC-1S Stainless Steel

T-LMSC-2S Stainless Steel

T-LMSC-3S Stainless Steel

T-LMSC-4S Stainless Steel T-LMSC-1S T-LMSC-2S

* special new model can be requested.

Material : Stainless Steel


Bolt - Stainless Steel

T-LMSC-3S

Roof Holders T-LMSC-4S

Hole copper stranded or tape conductors for hip, ridge and sheet tiled roof installation.

For Hip or Ridge Tiles

Dimensions (mm.)
Cat. No. Vary (H) Vary (L)
Max. Min. Max. Min.

T-LRHHR-100S 180 90 242 235

T-LRHHR-200S 180 145 340 225 T-LRHHR-100S T-LRHHR-200S


Material : Stainless Steel

Roof Holders
Hole copper stranded or tape conductors for hip, ridge and sheet tiled roof installation.

For Tile Sheet


Dimensions (mm.)
Cat. No.
H W L
T-LRTHS-205SF 20 25 205

T-LRTHS-405SF 20 25 405

Material : Stainless steel T-LRHTS


A

GROUNDING SYSTEM & LIGHTNING PROTECTION

Square Tape Support Aluminium

Suitable for 4 way connections, straight through


or tee joints for copper tape or aluminium tape.

Tape Size
Cat. No.
(mm.)
T-LSTS 253A 25 x 3

T-LSTS 254A 25 x 4

Material : Aluminium Alloy - BS EN 2898 , Bolt - Stainless Steel

Tape Test Connector Aluminium


Suitable for straight through tape joint.

Maximum Tape
Cat. No.
(mm)
T-LTTC 256A 26 x 8

T-LTTC 518A 51 x 8

Material : Aluminium Alloy - BS EN 2898 ,

Bolt - Stainless Steel

Cable Saddle $OXPLQLXP


Cable Size
Cat. No.
(mm2)
7/&670$ 5070

7/&6120$ 95 - 120

Material : Aluminium Alloy - BS EN 2898 ,


Bolt - Stainless Steel

GROUNDING SYSTEM
& LIGHTNING PROTECTION A A-27
A

GROUNDING SYSTEM & LIGHTNING PROTECTION

Cable to Tape Clamp Aluminium


Suitable to connect conductor to tape.

Cable Size Tape Size


Cat. No.
(mm2) (mm.)
T-LCTC 35-253A 35 - 120 25 x 3

Material : Aluminium Alloy

Cable Cross Clamp Aluminium


Clamp suitable for 4 way connections, straight through or tee joints for cable.

Cable Size
Cat. No.
(mm2)
T-LCCC 35-70A 35 - 70

T-LCCC 95-120A 95-120

Material : Aluminium Alloy

Tee Clamp Aluminium


Clamp used for forming tee joints for cable.

Cable Size
Cat. No.
(mm2)

T-LTC 70A 50 - 70

T-LTC 120A 95 - 120

Material : Aluminium Alloy

A-28
GROUNDING SYSTEM
& LIGHTNING PROTECTION A
Copper-Bonded Ground Rod
Standard Ground Rod Single Type (UL-Listed)

Dia. Size Actual Size Length


Cat. No.
(inch) (mm.) (Ft.)
IH-858 5/8 14.2 8
IH-1058 5/8 14.2 10
IH-834 3/4 17.2 8
IH-1034 3/4 17.2 10

Standard Ground Rod Single Type

Dia. Size Actual Size Length


Cat. No.
(inch) (mm.) (Ft.)
IH-658 5/8 14.2 6

Sectional Ground Rod Screw Type (UL-Listed)

Dia. Size Actual Size Length


Cat. No.
(inch) (mm.) (Ft.)
IHP-858 5/8 14.2 8
IHP-1058 5/8 14.2 10
IHP-834 3/4 17.2 8
IHP-1034 3/4 17.2 10

Sectional Ground Rod Screw Type

Dia. Size Actual Size Length


Cat. No.
(inch) (mm.) (Ft.)
IHP-658 5/8 14.2 6

Standard Ground Sectional Ground


Rod Rod
(Single Type) (Screw Type)

Couplings Ground Rod For Screw Type

Dia. Size
Cat. No.
(inch)
LEH-58R 5/8

LEH-34R 3/4

Product Features
> Copper is a molecularly bonding to the thickness of the copper-bonded steel core at any point. Shall not be less than
250 microns (0.25 mm.).
> Steel is used as a core made of low carbon steel with a tensile strength.
> Copper coating will not crack
> Corrosion resistance while providing tee lowest resistance to ground.
> Steel core provides driving strength, copper bonded provides conductivity with the soil.
> The fixed and durability of copper plated with Jacket Adherence test and Bending Test standard UL-467.

GROUNDING SYSTEM
& LIGHTNING PROTECTION
A A-1
�\��u,,
it3
'''"''
TOPWELD
GROUNDING SYSTEM & LIGHTNING PROTECTION

Concrete Inspection Pit


Concrete Inspection Pit are designed to convenient
in maintenance and measure ground resistance on
lightning protection system.

Dimensions (mm.)
Cat. No.
L W H
T-GCIPB 330 330 254

Material : Concrete

3,000 kg

Ground Bar Pit


These earth bars fit into the slots provided in the concrete inspection housing
and are used when multiple connections to the earth rod are required.

Dimensions (mm.) No. of Ø Hole


Cat. No.
L W T Hole (mm.)
T-GBP-5 315 50.8 6.35 5 10

T-GBP-7 315 50.8 6.35 7 10

Material : Tin Plated Copper Bar With Bolt - Stainless Steel

GROUNDING SYSTEM
& LIGHTNING PROTECTION A A-11
Ground Test Box

PVC Test Box


PVC Test boxes with connection bar are suitable for inspection
and testing point for grounding system.

Lug Size Dimensions (mm.)


Cat. No. 2
(mm ) L W H
T-GPVCTB 16 - 120 200 150 100

Material : Box - ABS IP66 , Bolt - Stainless steel

Aluminium Test Box


Aluminium Test boxes are cast aluminium with connection bar.
They are suitable for inspection and testing point for grounding system.

Lug Size Dimensions (mm.)


Cat. No.
(mm2) L W H
T-GATB 16 - 120 260 163 77

Material : Box -Cast Aluminium Alloy , Bolt - Stainless steel


Bi-Metallic Connector

This connectors are used in bi-metallic


earthing systems. It is recommended to
use inhibiting compound with this assembly.

Cat. No. Materials

T-LBMC Copper / Aluminium

Material : Copper / Aluminium Bolt - Copper, Stainless Steel

Bi-Metallic Washer Connector


This connectors are used in bi-metallic earthing systems. It is recommended to use inhibiting
compound with this assembly.

Hole Size
Cat. No. Materials
(mm.)
T-LBWC-12 Copper / Aluminium 14

Material : Copper / Aluminium

A-29
GROUNDING SYSTEM
& LIGHTNING PROTECTION A
Aluminum Compression Type Terminal Lug

For used on :
Aluminum Cable according to TIS 293

FOR ALUMINUM CABLE DIAMENSION OF COMPRESSION TYPE TERMINAL LUG

Cat.No. OVERALL
SIZE mm2 DIAMETER OF DØ dØ L1 L2
CONDUCTOR

+5
LW351 35 6.95 14.0 ( + 0.4) 7.85 ( + 0.15) 125 75
- 0
+5
LW501 50 8.33 16.0 ( + 0.5) 9.75 ( + 0.25) 125 75 - 0
+5
LW701 70 9.73 18.5 ( + 0.5) 11.25 ( + 0.25) 130 75 - 0
+5
LW951 95 11.45 23.0 ( + 0.5) 13.25 ( + 0.25) 140 75 - 0
+5
LW1201 120 12.95 23.0 ( + 0.5) 14.75 ( + 0.25) 145 75 - 0
+5
LW1851 185 17.64 28.5 ( + 0.5) 18.3 ( + 0.25) 155 75 - 0
ELECTRICAL CONNECTIONS

วิธีเชื�อมต่ อกราวด์ หลอด

1. ชิ �นส่วนต่างๆทังหมด
� ได้ ถกู บรรจุอยูใ่ นแบบหล่อ ซีลยางถูกบรรจุในส่วนด้ านล่างสุดของแบบหล่อ เพื�อป้องกันการรั�วไหล
2. สอดสายไฟลงในสลีฟ และวางแท่งกราวด์หลอด
3. เทผงเชื�อมลงในเบ้ า OneTime เตรี ยมเชื�อมโลหะในแม่พิมพ์
4. ปิ ดฝาเคาะผงที�ค้างก้ น ตรงปากทางนําร่องจุดชนวนระเบิดโดยใช้ ปืนสําหรับจุดเท่านัน�
5. เสร็จสิ �นการเชื�อมต่อสายแบบหล่อของ OneTime

คําเตือน: ก่ อนที�จะทําการเชื�อมต่ อทุกครั ง� เพื�อความปลอดภัยควรอ่ านรายละเอียดข้ อควรระวังและวิธีการทํางาน


ตามขัน� ตอนคําแนะนําตามคู่มือในกล่ อง OneTime โดยผู้ชาํ นาญการ

ข้ อควรระวัง !! ห้ ามเก็บไว้ ในที�เปี ยกชืน� , ระวังแตก

1 2 3 4 5

All parts packed Insert Cable in Dump OneTime Ignite with flint gun. Finished OneTime
In Mold.,Rubber Sleev and Weld metal in mold. Connection.
Seal in mold bottom Place Rod.
Prevents leaking.

Prior to marking a connection.,the detailed instructions and safety


precautions provide with each OneTime Mold should be read.
GUNKUL CATALOG & PRICE LIST

A-14
The TOPWELD "ONE TIME"
Connection is a ceramic disposable unit replacing the familiar semi-permanent graphite mold and
associated Handle clamp.
The TOPWELD "ONE TIME"
Consists of the ceramic mold which contains :
: The TOPWELD Weld metal
: a metal disk
: a flared sleeve or sleeves
: a cover

Type CC1 : Cable End to End Type CC4 : Cable Cross


Cat No. Cable Size (sq.mm) Cat No. Cable Size (sq.mm)

CC1-1616 16 CC4-1616 16
CC1-2525 25 CC4-2525 25
CC1-3535 35 CC4-3535 35

CC1-5050 50 CC4-5050 50
CC1-7070 70 CC4-7070 70

CC1-9595 95 CC4-9595 95
CC1-120120 120 CC4-120120 120
CC1-150150 150 CC4-150150 150
CC1-185185 185 CC4-185185 185
CC1-240240 240 CC4-240240 240
CC1-300300 300 CC4-300300 300

Type CC2 : Cable Run & Tap Type CB1 : Cable to Bar
Cat No. Cable Size (sq.mm) Cat No. Cable Size (sq.mm)

CC2-1616 16 CB1-16 16
CC2-2525 25 CB1-25 25
CC2-3535 35 CB1-35 35

CC2-5050 50 CB1-50 50
CC2-7070 70 CB1-70 70

CC2-9595 95 CB1-95 95
CC2-120120 120 CB1-120 120
CC2-12095 RUN 120 TAP 95 CB1-150 150
CC2-185185 185 CB1-185 185
CC2-240240 240 CB1-240 240
CC2-300300 300 CB1-300 300
The TOPWELD "ONE TIME"
Connection is a ceramic disposable unit replacing the familiar semi-permanent graphite mold and
associated Handle clamp.
The TOPWELD "ONE TIME"
Consists of the ceramic mold which contains :
: The TOPWELD Weld metal
: a metal disk
: a flared sleeve or sleeves
: a cover

Type GR1 : Cable to Rod Type NT3 : Cable Run & Tap to Rod
Cat No. Cable Size (sq.mm) Rod inch Cat No. Cable Size Rod inch
GR1-5816 16 NT3-581616 16
GR1-5825 25 NT3-582525 25
GR1-5835 35 NT3-583535 35

GR1-5850 50 NT3-585050 50
GR1-5870 70 NT3-587070 70

GR1-5895 95
120 5/8" or 3/4" NT3-589595 95 5/8" or 3/4"
GR1-58120
GR1-58150 150 NT3-58120120 120
GR1-58185 185 NT3-58150150 150
GR1-58240 240 NT3-58185185 185
GR1-58-300 300 NT3-58240240 240
NT3-58300300 300

Type GT2 : Cable Horizontal to Rod Type XT4 : Cable Cross to Rod
Cat No. Cable Size Rod inch Cat No. Cable Size Rod inch
GT2-581616 16 XT4-581616 16
GT2-582525 25 XT4-582525 25
GT2--583535 35 XT4-583535 35

GT2-585050 50 XT4-585050 50
GT2-587070 70 XT4-587070 70

GT2-589595 95 5/8" or 3/4" XT4-589595 95 5/8" or 3/4"


GT2-58120120 120 XT4-58120120 120

GT2-58150150 150 XT4-58150150 150


GT2-58185185 185 XT4-58185185 185
GT2-58240240 240 XT4-58240240 240
GT2-58300300 300 XT4-58300300 300
A
GROUNDING SYSTEM & LIGHTNING PROTECTION
Ground Station
Power Ground Station

Connect ground conductor wires to earth electrode.

Busbar No. of Ø Stud Dimensions (mm.)


Cat. No.
(mm.) Hole (mm.) L W H
T-GSPS-6 50.8 x 350 x 6.35 6 14.3 350 148 76.35

T-GSPS-8 50.8 x 440 x 6.35 8 14.3 440 148 76.35

T-GSPS-12 50.8 x 610 x 6.35 12 14.3 610 148 76.35

T-GSPS-6D 101.6 x 350 x 6.35 12 14.3 350 148 76.35

T-GSPS-8D 101.6 x 440 x 6.35 16 14.3 440 148 76.35

T-GSPS-12D 101.6 x 610 x 6.35 24 14.3 610 148 76.35

* special Length size can be requested

Material : Tin Plated Copper Bar - BS EN 13601 , Bolt - Stainless Steel


Support - Hot Dip Galvanized Steel with Insulator

Communication
Ground Station

Connect ground conductor wires to earth electrode.

Busbar No. of Ø Stud Dimensions (mm.)


Cat. No.
(mm.) Hole (mm.) L W H
T-GSCS-200 101.6 x 200 x 6.35 6 10 200 148 76.35

T-GSCS-300 101.6 x 300 x 6.35 11 10 300 148 76.35

T-GSCS-400 101.6 x 400 x 6.35 15 10 400 148 76.35

T-GSCS-450 101.6 x 450 x 6.35 18 10 450 148 76.35

T-GSCS-600 101.6 x 600 x 6.35 24 10 600 148 76.35

* special Length size can be requested

Material : Tin Plated Copper Bar - BS EN 13601 , Bolt - Stainless Steel


Support - Hot Dip Galvanized Steel with Insulator
GROUNDING SYSTEM
& LIGHTNING PROTECTION A A-9
�\\�u,,
�[3TOPWELD
'''"''
LIGHTNING PROTECTION & ACCESSORIES

Stranded Copper Conductor

Number and
Cable Size
Cat No. Diameter of Wire
(mm2) (no./mm)
T-SCC 010 10 7/1.35
T-SCC 016 16 7/1.70
T-SCC 025 25 7/2.14
T-SCC 035 35 19/1.53
T-SCC 050 50 19/1.78
T-SCC 070 70 19/2.14
T-SCC 095 95 19/2.52
T-SCC 120 120 37/2.03
T-SCC 150 150 37/2.25
T-SCC 185 185 37/2.52
T-SCC 240 240 61/2.25
T-SCC 300 300 61/2.52
T-SCC 400 400 61/2.85
T-SCC 500 500 61/3.20

Material : Copper
Reference Standard : TIS 2427-2552

Hard Draw Bus Bar


Suitable for grounding connection.

Size Coil Size Size (mm.)


Cat No. A B
(mm2) (m.) Width Thickness
T-HDBB304 120 5 30 4

T-HDBB324 128 5 32 4

T-HDBB305 150 5 30 5

T-HDBB325 160 5 32 5

T-HDBB405 200 5 40 5

T-HDBB505 250 5 50 5

* Other size is also available upon request.


Material : Copper - TIS 408

A-36
GROUNDING SYSTEM
& LIGHTNING PROTECTION A
CERTIFICATE AND TEST REPORT
KDER.E120176 - Grounding and Bonding Equipment Page 1 of 1

KDER.E120176
Grounding and Bonding Equipment
Page Bottom

Grounding and Bonding Equipment

See General Information for Grounding and Bonding Equipment

INTELLI INDUSTRIA DE TERMINAIS ELETRICOS LTDA E120176


AV MARGINAL 680
14620-000 ORLANDIA, SP BRAZIL

Trademark and/or Tradename:

Grounding rod couplings LEH-34, -58.

Grounding rod clamps TH-34-R, -58-R.

Grounding electrodes IH-812, -834, -858, -1012, -1034, -1058, IHP-834, -858, -1034, -1058.

Last Updated on 2002-07-25

Questions? Print this page Terms of Use Page Top

м 2016 UL LLC

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2016 UL LLC".

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name... 5/13/2016
CERTI FI C ATE OF COMPLI ANCE
Certificate Number UL-US-2002881-0
Report Reference E506106-20200921
Date 29-Sep-2020

Issued to: G K ASSEMBLY CO LTD


110/9-10 Moo2 Mahasawad Sub-District
Bangkruai District Nonthaburi
Thailand 11130

This is to certify that OVHF - Lightning Protection System Components Certified


representative samples of to IEC Publications
See Addendum Page for Product Designation(s).

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: IEC 62561-1, 2nd Ed., Issue Date: 2017-03-01

Additional Information: See the UL Online Certifications Directory at


https://iq.ulprospector.com for additional information

This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow-Up
Services Procedure provides authorization to apply the UL Mark.

Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL’s
Follow-Up Services.

Look for the UL Certification Mark on the product.


UL-US-2002881-0
E506106-20200921

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTI FI C ATE OF COMPLI ANCE
Certificate Number UL-US-2002881-0
Report Reference E506106-20200921
Date 29-Sep-2020

This is to certify that representative samples of the product as specified on this certificate were tested according
to the current UL requirements

Model Category Description


T-GATB Ground Test Box
T-GH 3 Clamp Bonding 2 Cables To Flat Surface
T-GM 3 Clamp Bonding Cable to Flat Surface
T-GSPS-12 Power Ground Station
T-GSPS-12D Power Ground Station
T-GSPS-6 Power Ground Station
T-GSPS-6D Power Ground Station
T-GSPS-8 Power Ground Station
T-GSPS-8D Power Ground Station
T-GTL 120 Terminal Lug Socket
T-LAST 58-253 Copper Alloy Adjustable Saddle
T-LCCC 35-70 Cable Cross Clamp
T-LCTC 120-253 Cable to Tape Clamp
T-LSTS 253 Copper Alloy Square Tape Clamp
T-LSTS 253A Aluminum Square Tape Clamp
T-LSTS 254A Aluminum Square Tape Clamp

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTI FI C ATE OF COMPLI ANCE
Certificate Number 20191120-E506106
Report Reference E506106-20190731
Issue Date 2019-NOVEMBER-20

Issued to: G K ASSEMBLY CO LTD


110/9-10 Moo2 Mahasawad Sub-District
Bangkruai District
Nonthaburi 11130 THAILAND

This certificate confirms that LIGHTNING PROTECTION SYSTEM COMPONENTS


representative samples of CERTIFIED TO IEC PUBLICATIONS
Air Termination Rod,
T-LBAT-58-500, LBAT-58-600, LBAT-58-1000,
T-LBAT-58-500A, T-LBAT-58-600A, T-LBAT-58-1000A

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: IEC 62561-2, Lightning Protection System Components


(LPSC) - Part 2: Requirements for Conductors and Earth
Electrodes
Additional Information: See the UL Online Certifications Directory at
https://iq.ulprospector.com for additional information.

This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow-Up
Services Procedure provides authorization to apply the UL Mark.

Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL’s
Follow-Up Services.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1
Issued to: G K ASSEMBLY CO LTD
110/9-10 Moo2 Mahasawad Sub-District
Bangkruai District Nonthaburi
Thailand 11130

This is to certify that OVHF - Lightning Protection System Components Certified


representative samples of to IEC Publications
See Addendum Page for Product Designation(s).

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: IEC 62561-4, 2nd Ed., Issue Date: 2017-07-01

Additional Information: See the UL Online Certifications Directory at


https://iq.ulprospector.com for additional information

This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow-Up
Services Procedure provides authorization to apply the UL Mark.

Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL’s
Follow-Up Services.

Look for the UL Certification Mark on the product.


UL-US-2002880-1
E506106-20200922
This is to certify that representative samples of the product as specified on this certificate were tested according
to the current UL requirements

Model Category Description


T-LTS 253 Tape Support For Copper
T-LTS 253A Tape Support For Aluminum
T-LTS 254A Tape Support For Aluminum
f, nmiur ff frfl u atrff dilnndrufi orJsr mdtm g
lnOH lNO STEEL INSTITUTE OF THA'ILAND

TESTING CENTER Page 1 of 3

Testing/Ana[ysis RePort

lSlT No. 3554/2016 August 25,201.6

Request No. 593081

Date of Request August 10,2016

Customer G.K. ASSEMBLY CO.,LTD

tto/g-to Moo 2 Bangkruai-chongtanom Rd,. Mahasawat sub-district

Bangkruai District, Nonthaburi 111,30 Te[: 02-985-2252-3 ext 107

Type of Sample A[uminum At[oy

Method of Testing/AnatYsis 1,.lSO 6892-1, :2009 : Tensile test


2. ISO 6507-t: 2005 : Vickers hardness test

Testing/Ana[ysis Resutt The Results are Attached 1 to 2

Tested by :\- Ns'(?*- Checked by cn{,^, \ui


(Mr.Nittipat lntarasamai) (Mr.Tossapon Chettaisong)

Material Testin gMnatysis Officer Academic Team

Tested by Approved by
J fu/F
(Mr.Akanit Thon gktuen g) (Mr.Prachuab Longsuwan)

MateriaI Testin g&Anatysis Officer QuaLity Manager

1. The above resutts are valid exclusively for tested/analysed samples as mentioned in this report.
governor of lSlT
2. pub[ication of the resutts on testing and ana[ysis is prohibited unless written permission is obtained from the

zz- lvrmrt:
o1n1fil1UnllBt {u 1-2 toflnflJnr nuurrrsflr 4 unr.:nrytru.r !{nnao.!!ng n?-.:rvrv{'l totto lvrt, a27P-4402-7,02713-6290-2 02 713'6294
d m riul n fr n u aB ff fr n fl dr u ri orlecl n d[ ms
B

inoru Rruo srEEL INsrlrurE oF THAILAND

TESTING CENTER Page 2 of 3

Attachment 1 : Tensite test results


August 25,201,6
lSlT No. 3554/2016

Request No. 593081

Test Date August 1-9,2016

Testing Laboratory 1" F[. Bureau of lndustrial Sectors Deve[opment Building, Room 105

Customer G.K. ASSEMBLY CO.,LTD

SampLe Aluminum A[[oy

Environ menta I Conditions : Temperature 24.3 'C, Relative Humidity 42o/oRH

Tested by : Universal Testing Machine Model : AG-100KN| M2

Sampte Name Atuminum Attoy

TC 5923027
-tc 5923A28
Operation No. TC s923026

Test items ResuLt Resutt Resutt

Maximum toad (kN) 8.56 8.64 8.49

Tensite strength (MPa) 1,23.74 133.45 131.63

** / -14 1.52
Etongation (7o)

Remark : t. 0.2o/o Proof

2.(**) Fracture outside gauge marks

valid exclusively for


J- \relF{a
tested/analysed samples as mentioned in this report.
tr-*rt
1. The above resu[ts are

governor of lSlT
2. publicat]on of the results on testing and analysis is prohiblted unless written permission is obtained from the

t&u t-z toafl6fin? nuuyrrsful 4 url.rilfstnu{ rsnano{lrlg t ot t o lut: oz r 124402-7. 02 7 1t-o2go-2 tumre: 0z 7 13'6294

FM-'1 7025-TC-002 (24101 149) Rev.O1


a o r riu r ff fr'n u as r ffi fr nn d'ru ri arJae t ndlm n
IRON AND STEEL INSTITUTE OF THAILAND

TESTING CENTER Page 3 of 3

Attachment 2 : Hardness test resutts

lSlT No. 3554/2016 August 25,201,6

Request No. 593081

Test Date August 24,201,6

Testing Laboratory L" FL. Bureau of lndustrial Sectors Development Building, Room 102
Customer G.K. ASSEMBLY CO.,LTD

Sampte A[uminum A[[oy

EnvironmentaI Conditions Temperature 25.5 "C, Relative Humidity 55 o/oRH

Tested by STRU E RS/Duram i n-5 Type 05656 242 Serial N o : 5655349


Unit : HV 0.3

Sampte Name Atuminum Attoy

Operation No. TC5923029 TC5923030 TC5923037

Point Resutt Resutt Resutt

1 100.6 97.2 93.2

2 1,1,8.7 r02.2 r04.2

3 98.6 1"0t.3 98.3

4 92.2 96.1 109.7

5 94 97.1 109.3

Average 97.7 98.5 to3.9

Remarks :The Average vatues are catculated by omitting maximum and minimum values

i Nf\-tF{"
1. The above results are valid exc[usiveLy for tested,ianalysed samples as mentioned in this report'

2. publ.icagon of the results on testing and analysls is prohibited unless written permission is obtained from the governor of lSlT

M-1 7025-TC-002 (24101/49) Rev.01

You might also like