Fruit Imbalance

RCA Breakdown Problems Interim Containment Action Permanent Corrective Action

Man Bins not properly segregated by FSD


No FSD data
Method
RA & NRA requirements
Unquantified FSD per bin/truck
Slow delivery of fruits or hand to mouth issue Utilize Accumulator to cater
Material FSD fluctuation (Elevate
Not properly graded
Accumulator, extend sidings)
Process bin-tail gate and provision of Direct/ High
Speed conveyor; and has the
Underutilized Accumulator ability to side feed to
No Direct Feed Conveyors Direct Feed Conveyor for 1T Fruits Accumulators.

Machine
Machine breakdown eg. ginaca., conveyors

Measurement Long holding time ( exceeded 12 hrs) for IQF requirement


M’vironment Heavy rain

1
Low Recovery-Bruising
Interim Containment Permanent Corrective
RCA Breakdown Problems
Action Action
Man Mishandling
Wrong Handling Procedure
Method
Fruit Pile Up
Delivered with Bruising
Material
High Shell Color
Sharp Edges
Establish a standard applicable
drop height and include in the
High Drops Provision of Decelerator Flaps future design
Machine
Simplify system by reducing
Quick Turns number of transfers before
Preparation
Measurement
M’vironment

2
Low Recovery – Fruit Upsize/ Downsize
Interim
RCA Permanent
Problems Containment
Breakdown Corrective Action
Action
Man
Method
Material Unique Fruit Sizes
Change Grader Design
Machine Grader Design
specifically grader pitch
Measurement
M’vironment