Section 25 V3.20 - TSConfig32
Section 25 V3.20 - TSConfig32
TSConfig32
539.1259/02
De La Rue TCR Twin Safe TSConfig32
TSConfig32
All rights reserved. Without written permission of the publisher it is forbidden to duplicate or copy in
any way this publication, partly or completely. De La Rue reserve the right to amend or change any
part of this document without prior notice.
Administration
Document TSConfig32
Doc. number 539.1259/02 Language english
Edition date 27th September 2002 Version 3.20
FIling www.askdelarue.com
Created with FrameMaker 6.0
Version
Edition Description Date
1.00 First edition 30-03-2000
2.00 Revised edition 14-07-2000
3.20 Revised edition 27-09-2002
TSConfig32
Contents
1 Introduction ..................................................................... 5
2 How do I work with TSConfig32 ? .......................... 8
3 Communication Box .................................................... 10
4 Description ..................................................................... 11
5 Configuration ................................................................ 20
6 Roll Storage Module (RSM) Configuration .......... 25
7 Configuration TS Hardware ....................................... 32
8 General Options............................................................ 33
9 Safemaster...................................................................... 50
10 Glossary ........................................................................... 59
11 Index ................................................................................. 65
1 Introduction
1.2 Presentation
1.2.3 Dialogue
Dialogue requests are always placed inside quotation marks,
Presentation range, see chapter 4.7, page 17 “Client Range”.
1.2.5 TAB‘s
TAB‘s are sub-menu’s (lower dialogue level) and always displayed in bold
print the same as the menu’s.
1.2.6 Range
The range of entries are always displayed inside of quotation marks.
Example:
Language range
Supervisor The Supervisor has the power to authorize himself and a system administra-
tor, and also to change or modify his own password.
At delivery of the TCR Twin Safe two supervisors will have been authorized.
000000001 ADM
000000002 ADM
System The system administrator has the power to authorize customer advisors and
administrator also change or modify the complete configuration of the TCR Twin Safe.
A total of four system administrators can be defined.
Remarks The system administrator can define up to 27 customer advisors.
Define / Delete A list of all the currently configured users is displayed in the middle of each
user of the dialogue boxes (list box). A new user can be defined over the “New
Entry” button. The “Delete” button deletes selected users from out of the
list box. A user entry can be modified with the help of the “Modify” button
(user ID and password). Because of security reasons, the password must be
verified twice at any modifications to the user data.
Note In order to leave the current modifications being processed and to close the
dialogue fields, click on “Cancel“ or press the Esc key.
Selection- Activation
fields panels
Activation
panels
What‘s a Combobox?
Combobox Combobox
not selected selected
3 Communication Box
This will appear whenever an application communicates with the TCR Twin
Safe for a long period of time (approximately 5 seconds).
By clicking on the “Abort” option you can stop the communication. This
will also result in activation of the main application once again.
Under certain circumstances the TCR Twin Safe will have to be started-up
again.
4 Description
Transmission- Station-
speed address
Side
being
used
COM Port
of the PC
Ensure that at connection of the service port the baud rate has been set to
57600bps and both connection settings for the operators 1+2 have been
set to 9600bps. You also have the possibility to set the communication
parameters automatically using the “Auto Detection“ box.
Transmission speed
in Baud rate
Communication- If no communication is possible with the TCR Twin Safe, then the error mes-
errors sage shown below will appear. Please check the communication parame-
ters, the COM-Port settings and the connection cable.
A list of all the currently configured users is displayed in the middle of each
of the dialogue boxes (list box).The “New Entry” button allows you to
define a new user. The “Delete” button deletes selected users from out of
the list box. A user entry can be modified with the help of the “Modify”
button (user ID and password). Because of security reasons, the password
must be verified twice at any entries or modifications to the user data.
If the login or password entry is not correct then the application will be termi-
nated.
Note In order to operate as the supervisor, you must first register (login) as the
supervisor. To do this, the supervisor must login for the first time at the TCR
Twin Safe, over TSConfig32 using a pre-defined user name and password.
Subsequently he can change his password and define system administrators.
In order to operate as the system administrator, you must first register as the
system administrator. In order to login as a system administrator, the supervi-
sor must have previously defined at least one system administrator.
• Menu bar: provides the user with direct access to all the commands and
dialogue options in the TSConfig32
• Main function bar: provides the user with quick access to all the com-
mands and dialogue options in the TSConfig32
• Status bar: informs the user about the current procedures between the
TSConfig32 and TCR Twin Safe and also displays the current time and
date.
• Client’s range: all dialogue options will be displayed in the client’s
range.
Status bar
Example: In order to open the main menu in the dialogue “Roll storage“
with tab “Empty RSM“, press the [Alt] key and the keys [R] and [P].
If you would like to change from one tab to another inside of a main menu,
then you must press the [TAB] keys in sequence.
In order to change inside a Tab from one control element to another, the
[TAB] key must be pressed a number of times until the selected element
has been reached. You can now select the element by pressing the
[RETURN] key (Windows Standard).
Inside of a pop-up menu, respective a listbox or ComboBox you will be able
to select an entry by using the Cursor-control keys for selection and then
pressing the [RETURN] key (Windows standard).
Example: In order to assign a new currency code, select from over the
menu bar the dialogue option “Note Configuration“ and open up the
“Assign Currency“ tab.
4.9 Configuration
To set the communication parameters please click on the menu option Tool,
and then Configuration in the sub-menu. The following dialogue will
appear:
Transmission- Station-
speed address
Side
being
used
LAN
Auto
find
Trans-
mission
speed
Note Ensure that at connection of the service port the baud rate has been set to
57600bps and both connection settings for the operators 1+2 have been
set to 9600bps.
You now have the possibility to select the chosen operating language.
Note After the selection / setting of the language, TSConfig32 has to be restartet.
5 Configuration
5.1 Configuration of the customer advisor
In order to implement configuration of a customer advisor, please click on
the “User“ button in the menu bar option and then on the “Customer
Advisor“ tab or equilivent menu option point in the main function bar.
A list of all the currently configured users is displayed in the middle of each
of the dialogue boxes (list box). A new customer advisor can be defined
over the “Define New” button. The “Delete” button deletes selected cus-
tomer advisors from out of the list box. Because of security reasons, the
password must be verified twice at any modifications to the user data.
In order to assign a currency code to a note, first select the note from out of
the list and then click on the the “Assign Currency Code.” ” button. All the
configured currency codes will then be listed in a dialogue field (see the seg-
ment relating to configuration of the currency codes). You can now select
the code to be used.
Listbox contents Index, Notes ID, Values, Supplement, Blocked, ISO and Currency codes,
RSM.
In order to assign a certain note to a roll storage module, first select a note
from out of the list and then click on the “Assign RSM” button. You will
now be able to choose one or more roll storage module’s from out of a list
to assign the note. If more than one roll storage module must be selected,
then this can be done as is usual with Windows Explorer, by pressing the
[Shift+Cursor] keys or [CTRL+Cursor] keys, or with the mouse using the-
help of these keys. In order to once again remove an assigned note from
out of a roll storage module, first select the note from out of the list and
then click on the “Release RSM” button.
Note The currency codes must previously be defined in the Currency menu.
Note Empty the roll storage module before the assignment procedure.
In order to assign a note to a roll storage module, first select a note from
the list and then click on the “RSM Assignment” button. You can now
select one or more roll storage modules from out of a list and assign the
note to one (or more) of them. If more than one RSM is selected using the
keys [Shift+Cursor] or [CTRL+Cursor] or via the mouse under a help-
option name for one of these key combinations (as is normal with Windows
Explorer). In order to remove an assigned note from out of a roll storage
module, select the note from out of the list and then click on the “RSM
Release” button.
RSM Allocations
In order to carry out an assignment procedure first select the corresponding
roll storage module that the assignment is specified for and then press the
“New Assignment” button. Subsequently you also have the possibility to
assign the note identification and note orientation
The requested orientation setting can be made in the orientation field.
“Not assigned” signifies that the orientation has no influence in this case
and no attention must be paid to it.
Assignment field
In the note identification option field, the user can select a chosen note
from out of the list of loaded notes.
Delete assignment In order to delete an allocation, select it from the tree directory and then
click on the “Delete Assignment” button.
Delete all In order to delete all allocations of a roll storage module, select the corre-
assignments sponding roll storage module and press the “Delete Assignment“ button.
In the range of the “Set Parameters“ you have the possibility to define the
operation data relating to the lower and higher pre-warning limits for the
number of notes and tape length. To do this first select the corresponding
roll storage module (to be used). TSConfig32 will display the current operat-
ing values. You can change these values. The new values will be transferred
by the TCR Twin Safe as soon as you have pressed the “Update” button. If
you do not confirm any changes or modifications that you have carried out,
they will be lost.
You can select the roll storage module to be emptied with the help of the
integrated RSM check button or click on the „None“ Button and then start-
up the withdrawal procedure by clicking on the “Start Withdrawal” button.
The markings in the check buttons will be resetted by clicking again on the
„None“ button.
Note You cannot log-on twice using the same password! This makes it impossible
to bypass the four-eye-principle.
The notes registered (stored) in the RSMs will be displayed on the tab. After
completion of the withdrawal procedure the actual number of notes will be
displayed. The data will then be compared with the original data. Any dif-
ferences will be displayed in the “Difference” column.
7 Configuration TS Hardware
In order to configuration the Roll Storage Module you have followings pos-
sibility.
Note After the update procedure only the number of accepted RSMs will be dis-
played in the menu roll storage module and the note configuration menu.
8 General Options
In order to display configuration of the general operation data in the TCR
Twin Safe, click on the “General“ button in the main function bar or equiv-
alent menu option in the menu bar. The corresponding dialogue will appear
in the display and will contain the following Tabs: System Status, Periodi-
cal Operation Times, Aperiodical Operation Times, TS Options, Copy
System Data, Journal and Daylight saving time.
By clicking on the selected LED the TSConfig32 will provide detailed infor-
mation regarding the problem in the corresponding component assembly.
A self test can be executed with the help of the “Start Self Test” button.
The current system status will consequently be displayed. A click on the
“Display History” button will initiate the output of the last command car-
ried out by the TCR Twin Safe. When the “Last Error” button is pressed,
the last error that has occurred will be display. The software versions of all
the modules found in the TCR Twin Safe can be displayed by clicking on the
“Software Versions” button.
Four LED’s extend the dialogue in providing information concerning the sta-
tus conditions of the deposit and withdrawal functions (“Deposit” / “With-
drawal”) and displays the current alarm status conditions (“External Alert” /
“Silent Alert”).
Important If the TCR Twin Safe is blocked, then no changes to the operating times
may be made and no “Open Door" commands executed; therefore it is not
possible to carry out any service procedures or revision during these times.
TSConfig32 shows on this menu segment the current configuration for all
four time windows for the seven weekdays. In order to change a time,
select the desired time field and then edit the contents of the field. The time
is entered in hh:mm format (Hours:Minutes). The entry 24:00 will be trans-
ferred to the safe at 23:59 and serves as a flag so that the safe will not be
switched off when the first time field for the next day begins with 00:00.
When a click is made on the “Update Times” button, all the time windows
will be checked for their consistency and if correct, transferred to the safe.
Note The “Update Times” button must absolutely be pressed, because other-
wise the changes will not become active!
Remarks:
The TCR Twin Safe does not check to see that the switch-on and switch-off
times overlap. If the switch-on time is defined later than the switch-off time,
then the TCR Twin Safe will be blocked the whole day.
The switch-on and switch-off times will be initiated immediately.
Configuration can be carried out here using the information relating to the
date (e.g. holidays) and special operating times. In this way holidays or spe-
cial working days that do not fall within normal periodical operation times,
can be taken into account. The aperiodical operation times are however
placed within periodic operation times, this means that during existing ape-
riodic operation times the periodic operation time will not be taken into
consideration. At delivery of the the TCR Twin Safe no aperiodic operation
times will have been defined.
In the range “Alarm Settings“ menu option you can configure a factor for
the withdrawal time period at occurrence of an alarm (Field Alarm Faktor).
The value will be transferred to the TCR Twin Safe when you click on the
“Set Alarm Factor“ button. In order to simulate an alarm click on the
“Activate Alarm” button. To deactivate the alarm once again, click on the
“Deactivate Alarm” button.
The alarm can also switch itself off after a certain period of time. In order to
activate this option, click on the checkbox “Automatic Alarm Reset” but-
ton. In this way an edit box will be activated where the reset time can be
entered.
The factory pre-programs the TCR Twin Safe with the following graphic:
10
9
8
7
6
Zeit [sec] 5
4
3
time 2
1
[sec] 0
0 100000 900000
Amount Betrag
Additional explanations:
• This curve must be defined for amounts in national currency; that is, for
currencies with the currency factor 1. The delay times for foreign curren-
cies are multiplied by the currency factor of the foreign currency.
• In the event of an alarm the delay time is multiplied by the alarm factor.
• The delay is counted down before feeding of the bank notes from the
TCR Twin Safe is started.
• When the command „Empty roll storage module“ is executed, the delay
is only counted down if this is requested in the telegram data.
• In TCR Twin Safe you must first define the number of classes and then
the values of the individual classes.
• Up to 10 classes can be defined.
120
100
80
Zeit [sec] 60
40
20
time
[sec] 0
0 5000 10000 30000 100000 900000
Amount Betrag
The “Copy Configuration and Operation Data“ option contains the follow-
ing selection fields:
1. You have the possibility to specify a time period from which the journal
lines will be loaded from. To do this, mark the radio button ”By Range”
option. Both the date and time settings can be entered into the four sub-
sequent fields from when and until when the journal date should be
loaded. If you would like to load the present day (today) starting from
midnight up to the current time, then you can enter in the times using
the tabulator key. The cursor will jump from one text field to the next
and carries out a standard initialization.
2. Alternatively, there is also the possibility to load the last xxx lines of the
journal. To do this, you must activate the radio button “Last xxx Lines”,
xxx is the string for the number of lines.
4. “All Lines” will load all of the available lines from out of the journal file.
In order to load the specified data journal lines, click on the “Load Journal”
button. The individual lines will subsequently be displayed in the lower part
of the dialogue field.
The loaded journal files can be exported as ASCII files when a click is made
on the “Export Data” button. It will open up a dialogue box that allows
you to specify a file name / path for the journal file. Subsequently, the data
will then be written into the file.
To make a time change click on the “New“ button. This will open a dia-
logue where data can be input (date, time, shifting plus or minus). To delete
an entry choose it from the list then click on “Delete“.
To modify an entry choose it from the list and click on “Modify“.
9 Safemaster
As an option, one or more Safemaster units can be connected to the TCR
Twin Safe. They allow objects of value to be processed that cannot be han-
dled by the roll storage module’s of the TCR Twin Safe because of their
dimensions or quality (foreign currencies, coins, cheques, banknotes of poor
quality etc.).
The number of drawers can be displayed at any time, whenever the Safe-
master has been configured in the TCR Twin Safe.
Important:
Whenever a Safemaster is configured in the TCR Twin Safe, the connection
to the Safemaster will test the state of the connection every time the „Test"
command is executed.
The type of Safemaster cannot be changed without first executing a new-
configuration procedure.
So that the drawers of the Safemaster can be used by the TCR Twin Safe, a
drawer currency must first be defined for every account. A drawer currency
is made up of an index text and the physical drawer number. The TCR Twin
Safe will generate a currency related index, over which the deposit and
withdrawal procedures are made.
Drawer operation is also possible with the Safemaster system without actual
connection of a Safemaster unit. This however must then be configured
using the physical drawer number equal to zero (0).
A number of various delay times can be set for operation of the Safemaster.
9.1.1 Configuration
In order to carry out configuration of the general TCR Twin Safe operation
data, please click on the “SafeMaster“ button in the main function line or
on the equilivant menu point in the menu option bar. The corresponding
dialogue will then appear in the display and contain the following tabs:
SafeMaster General, SafeMaster Drawer Currency and SafeMaster
Drawer Delay Times.
By selection of the buttons you have the possibility to display on-screen sort-
ing of currencies or drawers.
Use the “New Drawer Currency” button in order to configure a new cur-
rency to a drawer. A dialogue window will be displayed where the currency
code can be entered. The index text is an additional identification. It should
be used in order to describe more fully the corresponding drawer currency
(coins, cheques, etc.). The number of the drawer is required as the last entry
The new drawer currency will be registered in the root directory of the dia-
log.
Using the “Delete Drawer Currency” button, you can delete a selected
drawer currency entry in the root directory.
The following delay times are used in conjunction with the SafeMaster and
can be changed or set:
With the help of the “Unlock SafeMaster” button you will be able to open
all the drawers of the SafeMaster in sequence.
Drawer specific modifications can be carried out in the lower part of the dia-
logue field. First you must select the corresponding drawer and confirm
using the “Modify Delay Time” button. After this a dialogue window will
appear into which the new delay time can be entered.
In order to open a certain drawer, it must first be selected from out of the
list box. After this, the drawer will be opened after the defined delay time
shown in the field „Remaining time“ (countdown) has started to run down
and the “Open Drawer” button has been pressed.
By clicking on the “Empty Drawer” button the cash contents of all the
drawers will be reset. Before this procedure commences the TSConfig32 will
request authentification by another member of the bank personnel (four-
eye principle). This dialogue prevents the same user, (same user ID) to log-in
a second time over a different user level. This means that two different users
(different user ID’s) must log-in to confirm successful authentification!
The current delay time will be displayed. They can now be changed; the
range allowed is 0-9999 seconds. At delivery of the TCR Twin Safe the delay
time for each drawer will have been set to 0 seconds.
After you have selected the drawer with the help of the Combobox, you will
be able to enter the new time into the delay time field (in secs.) in order to
set the unlocking delay time for this SafeMaster drawer. It will only be pos-
sible to open the drawers after this time period has elapsed.
All of the drawer currencies will be deleted and the Safemaster registered as
not configured.
Important:
The configuration will also be deleted if the contents are not equal to 0.
If drawer currencies are defined using the physical drawer = 0, (e.g. coin
drawers), then they will not be deleted using this command.
This command can also be executed when a Safemaster is connected and a
current configuration must be deleted.
If the communication to a configured Safemaster is no longer functioning
(corresponding error messages at start-up and Safemasters operations),
then the configuration can be deleted using this command.
10 Glossary
Term Description
Alarm Alarm activation, see security functions.
In the case of an alarm, all withdrawal transactions can additionally
be delayed.
Application Application software also known as link software. The software dis-
Programs plays the input windows at the operators terminal and also sends
and receives commands to and from the TCR Twin Safe via the
interface. The link software also has the responsibility for TSUSER
operations and simultaneously supervises the account processing of
the bank.
Authorization Authorization permission protected by a password that allows
access to the functions of the TCR Twin Safe.
Term Description
Currency Data Software for recognition of a currency.
Customer Advisor Operator of the TCR Twin Safe. Lowest user level in the TSUSER32.
Customer Currency All banknotes that are to be processed by the TCR Twin Safe must
Code first be allocated a free selectable currency code (for example.US $)
and then configured.
Data-Log Contains recordings of all the system internal events (including con-
trolling procedures and transactions).
Delay Times Free definable time delay period dependent of the amount for the
banknote output. This must be entered by the supervisor or system
administrator.
Event Messages Comprised of the event status and event number. If both are 0,
then the function has been executed free from errors.
Event messages are divided into detail events and main events.
Every event occurring will be displayed on the monitor and / or the
corresponding event number will appear on the printer.
Three digit event numbers will be displayed on the monitor. Four
digit numbers on the printer, in the display module and in the log
file.
Exception Messages See also event messages or exceptions. Event messages are not nec-
essarily error messages.
Term Description
Initialization All configuration settings will be deleted whenever the MCU is ini-
tialized. Subsequently a new configuration, a new visible file and a
new language must be loaded and set.
Journal File Journal file of all executed actions. Also known as the logfile.
Journal Printer All actions carried out by the TCR Twin Safe as well as all the event
messages will be placed in a protocol for the printer.
Language File This file contains the text for the error messages in all of the lan-
guages used. Current error text options include German (ger),
English (eng) and French (frc).
Module Description of individual components inside the TCR Twin Safe such
as the input module, output module, reader module etc.
Note Movement The position of a note movement inside the TCR Twin Safe is con-
Communication stantly monitored and transported and reported from module to
module. The position and distance to the neighboring notes are
constantly checked for their plausibility.
Off-line Operation The terminals of the customer advisors are all connected directly to
the TCR Twin Safe. Operation is carried out for example using the
TSUSER32 software from De La Rue. The processing of accounts is
carried out over a separate function procedure independent from
the TCR Twin Safe.
On-line Operation The terminals of the customer advisors are linked to the correspond-
ing EDP equipment of the bank. Operation of the TCR Twin Safe is
carried out using the host software.
Operation Times The TCR Twin Safe be blocked for free definable days or for certain
time periods by special software blocking commands.
Overflow Roll Storage Serves to store banknotes that cannot be placed into a roll storage
Unit unit(s) that has insufficient space. Only deposit transactions can be
carried out! Blocked for withdrawal procedures. This roll storage
unit must be emptied using the „Empty“ command.
Term Description
OVM Optical verification module. General term for reader module
Parameter Parameters are specific setting values that can be loaded using files
into a module of the TCR Twin Safe. These then serve to adjust the
logical and physical behavior of the module.
Printer If a printer is connected to the TCR Twin Safe, then all the executed
functions including their parameters as well as any possible occur-
ring events will be recorded. The events displayed by the printer are
indicated a a five digit number.
Remote Access General term for all defined access operations to a remote device of
a system over a communication medium.
The Remote Access is divided into:
- Remote Control
- Remote Diagnostic
Remote Diagnostics Possibility for remote requests or remote signalling of the status of
the device. Just information access without possibility of direct influ-
ence to operations of the device itself. These include:
- File transfer to a remote system (Upload)
- Request of the current status of the system and data
Roll Storage Assign- Assignments of various notes in the roll storage module’s.
ment
RSM Roll storage module. A roll storage module (RSM) is comprised of a
note transport module (NTSPM) and roll storage unit (RS).
Term Description
Safemaster A Safemaster is a drawer safe compartment that can be connected
to a TCR Twin Safe. Up to 4 Safemasters can be connected optional.
They serve to process and store objects of value, that because of
their dimensions or quality (foreign currencies, coins, cheques etc.)
cannot be automatically processed by the TCR Twin Safe.
Sensors Sensors or probes are elements that are able to process physical
procedures. The TCR Twin Safe contains the following types of
sensors
Transmission sensors
Position sensors
Reflex sensors
Rotation sensors or timing wheels
Reading sensors
Inductive distance sensor for thickness measurement
Storage Module Device for storing entered banknotes. There is a difference for the
SPM above (RST) and SPM below (RSB).
Storage System All roll storage units available in the TCR Twin Safe make up the
(RSS) storage system.
Storage Unit A storage unit (STU) = two mounted on one another roll storage
module’s RSM.
System Administrator EDP Supervisor for the system; first contact person for the customer
advisor. Second user level in the TSUSER32.
Term Description
System Status The following information will be displayed:
SW-Versions, system language, operation status, blocked storage
module’s, number of storage module’s, last not corrected main
event, event status, printer connection yes/no, note reader type,
covered sensors and feedgates.
TSUSER32 Operating software for the TCR Twin Safe in off-line operation
User Names At delivery the following user names will have been defined:
User level B supervisor, user name =000000001
User level B supervisor, user name =000000002
The passwords will be issued by the bank. The user names can be
modified or changed.
Withdrawal Delay In the TCR Twin Safe, withdrawal procedures and emptying of the
Times roll storage module’s can have a time delay period appropriated by
a configured, amount dependent value. The device can also have a
supplementary withdrawal delay activated by the alarm.
11 Index
A Client range
configuration dialog 16
Accelerator keys
option 16
explanation 8
program framework 15
Alarm
Combobox
activate 40
definition 9
automatic reset 40
explanation 8
deactivate 40
factor 40 Communication
factor set 40 Baud Rate 12
settings 39 box display 10
simulation 40 error 12
parameter setting 18
Allocations
RSM 26 COM-Port
setting 12
Aperiodical
time options 37 Configuration
aperiodical time options 37
Assignment
currency code 22
delete RSM 28
currency codes 23
fields explanation 8
customer advisor 20
RSM 22
delay times 42, 43
Authentication dialog client range 16
user 13 drawer currencies 52
minimal 7
Authorization
note 21
administrator 7 printer flag 39
Automatic printer manager 40
alarm reset 40 Roll Storage Module 25
B safe door 39
SafeMaster 51
Baud Rate the first 7
connection for operator 12, 18 time change 49
service port 12, 18 time options 35
Button withdrawal delay times 39
explanation 8 connection
presentation 5 cable 12
C
Controlling side
Cable TSConfig32 58
connection 12
Copy
Cashier system data 44
dialog field 18
Currency
Change code configuration 23
system time 39 code edit 24
time 49 code modify 23
Example Login
combo box 9 administrator 13
Selection T
fields explanation 8
TCR Twin Safe
lists explanation 8
connect with SafeMaster 52
Service port
Time change
Baud Rate 12, 18
summer time 49
Service-Software TSConfig32 summer/winter 49
communication Box 10 winter time 49
description 11
Time options
general options 33
aperiodical 37
SafeMaster 50
configuration 35
Service-User-ID periodical 35
password 13
Tool
Setting option 18
communication parameters 18
Transmission
Language 19
detection 12
Side parameter 11
being used 11 speed define 11
user 11
TSCONFIG32
Simulate controlling side 58
alarm factor 40
TSConfig32
Start-Up elementary rules 8
first time 11 exit 15
how do work with 8
Station address
how do you work with 8
Input 11
installation 5
Status bar program framework 15
program framework 15 screen 15
who operates 7
Summer time
time change 49 TS-Software
TSConfig32 3
Supervisor
U
authorization 7
login 13 Unlocking
register 14 delay 41
System Used
data copy 44 PC time 39
language loading 39
User
status display 33
Button 20
time change 39
display configuration 20
System Administrator W
login 13
Winter time
max. definition 7
time change 49
System time
Withdrawal delay times
change 39
configuration 39