You are on page 1of 1

℄ CRUSHER

C 1900 VARIES VARIES


29⌀ @ 200
DOWELS W/

The information and know-how on this drawing are the property of P.T. Freeport Indonesia, and may not be copied or reproduced without the written permission of P.T. Freeport Indonesia, nor may they be used,in any manner directly or indirectly detrimental to the interest of P.T. Freeport Indonesia. This print is lent upon the express condition that it, and all copies thereof, are subject to return upon demand.
8950 12000 STD. HOOKS
(REF.)
3200 2000 5300 75
29⌀ @ 200 (E.W.) CLR.
6885 (REBAR SKEWED IN
VIEW, SEE TOP DUMP HOPPER WALL
REBAR PLAN ON ABOVE, FOR DETAILS SEE
℄ CRUSHER

2150
DWG. GC-O9260050) DWG. GC-O9260037

(2) SETS OF 16⌀


T.O.C. STIRRUPS @ 150
EL. 2747.050
TOP LAYER ROCK ANCHOR
LINERS, FOR BY U/G (TYP.)
DETAILS SEE DWG. SEE DWG.
GC-O9260033

1800
GM-09260021 (TYP.)

2200
MIDDLE LAYER
FOR EMBED STEEL
DETAILS SEE DWGS. C.J.
GS-O9260057 & 58
BOTTOM LAYER
⌀ SRC PAD B.O.C. EL. 2744.850

@ -32
T.O.C. EL. 2746.000

0
)
18

CLR.
2 ROWS OF

(6

40
(SEE DET. "2" ON

(REF.)
1850
(10) 32⌀

YP S
REBAR SKEWED IN VIEW,

(T RUP
DWG. GC-O9260049)

.)
(6)-32⌀

15 TIR
SEE BOTTOM LAYER REBAR PLAN

S
ON DWG. GC-O9260052

0
16
@
1
1000 SEE NOTE 3 THIS DWG. &

(2 IRR
)S U
ST
(MAX.) OVERBREAK REPAIR DETAIL

ET P S

C:\Users\snguyen\OneDrive - Freeport-McMoRan Inc\Documents\CRUSHER 603 LOWER_snguyen.rvt


ON DWG. GC-O9260052

S @
OF 1

16 50

YP S
(T RUP
SECTION B

.)
15 TIR

S
0
SCALE: 1 : 50 -

16

3650
@
GC-O9260050,52

(3) SETS OF 16 STIRRUPS @ 150


℄ CRUSHER

B
C

25 x 8000 LG. @ 150


VARIES 1900

-
-

MOTOR PAD

15000
(REF.)

℄ CRUSHER T.O.C. EL. 2746.416 A


(SEE DET. "1" ON
M.

SI
DWG. GC-O9260049) GC-O9260049
SI


M. 75
DUMP HOPPER WALL CLR.
ABOVE, FOR DETAILS SEE 29⌀ @ 200 (E.W.)
C

B (REBAR SKEWED IN
DWG. GC-O9260033 29⌀ @ 200
-

VIEW, SEE TOP


DOWELS W/

2150
REBAR PLAN ON
STD. HOOKS
DWG. GC-O9260050)

⌀ (2)-16⌀ STIRRUPS

16
2-ADD'L.

(TYP.)
@

500
T.O.S.
16⌀ x 2000 LG.
@ 150

ST ( T
15
IR YP
EL. 2747.050

0
RU .)
@ 100

PS
⌀ (TYP. 2-PLCS.) ROCK ANCHOR TOP LAYER
@ 16

BY U/G (TYP.)
0
LINERS, FOR

6150

1000
15

MIN.
PS F
RU S O

SEE DWG. DETAILS SEE DWG.


IR ET

1800
GC-O9260033
ST ) S

GM-O9260021 (TYP.)

2200
(2

FOR EMBED STEEL


C.J. DETAILS SEE DWGS.
⌀ GS-O9260057 & 58
16

16⌀x2600 STRAIGHT
@

ST ( T

BOTTOM LAYER
15

24⌀ ANCHOR BOLTS DOWELS @ 400


IR YP
0
RU .)

B.O.C. EL. 2744.850


PS

FOR 610UB EMBEDS,


(6 18

CLR.

40
)- 0

SEE DET. ON THIS 2 ROWS OF


32
@

(6)-32⌀
DRAWING (TYP. 16) REBAR SKEWED IN VIEW,
SEE BOTTOM LAYER REBAR PLAN
ON DWG. GC-O9260052

650
L.P. T.O.C.
EL. 2745.836
2 1000
(MAX.)
SEE NOTE 3 THIS DWG. &
OVERBREAK REPAIR DETAIL
ON DWG. GC-O9260052

SECTION C
SCALE: 1 : 50 -
GC-O9260050,52
NOTE:
DOWELS & TOP LAYER
75 (20)-32⌀ @ 150 (17)-16⌀ @ 300 50 CLR.
STIRRUPS NOT SHOWN
FOR CLARITY. CLR. (TYP.)
(2)-24-C-1000-P460-T200 NOTES:
(WITH ADDITIONAL WASHER
PL 12x100x100, LEVELING
MIDDLE LAYER
1. FOR GENERAL NOTES, SEE DWG. 02022918-GC-00000001.
℄ CR-0603
PL 12x100x100 AND NUT FOR
EACH ANCHOR BOLT.)
REBAR PLAN AT T.O.C. EL. 2745.909 (U.N.O.) 2. FOR ROCK ANCHORS SEE DWG. GC-O9260033.
(TYP. 8 PLACES) SCALE: 1 : 50
3. IF OVERBREAK IS MORE THAN 1000mm, NOTIFY NOLA ENGINEERING.
FOR OVERBREAK BETWEEN 250mm AND 1000mm ON ROCK EDGE
84 SUPPORTING CRUSHER FOUNDATION, REPAIR PER DETAIL SHOWN
27 P.) 610UB, SEE DWG. ON DWG. GC-O9260052.
Y
(T GS-O9260057
4. SEE DWG. GE-O9260514 AND GE-O9260515 FOR ELECTRICAL CONDUITS
T.O.S.

CRUSHER FOUNDATION MIDDLE LAYER REBAR PLAN


AND GE-O9260604 FOR GROUNDING BEFORE PLACING CONCRETE.
EL. 2746.909
16
25 P.) 5. DIMENSIONS ARE IN MILLIMETERS AND ELEVATIONS ARE IN METERS.
Y
(T NUT
6. WHERE NECESSARY, REBAR SPLICES SHALL BE STAGGERED. MINIMUM SPLICE
WASHER LENGTHS SHALL BE AS FOLLOWS:
℄ CR-0603 PL 12 25⌀ = 1850mm
29⌀ = 2150mm
PL 25 C.J. 32⌀ = 2375mm
LEVELING PL 12 T.O.C. 36⌀ = 2675mm
(TYP
45°

EL. 2745.909
7. ALL REBAR WHICH EXTEND TO RIB SHALL BE OVER FABRICATED BY 1000mm
.)

ADD'L. NUT AND BE FIELD TRIMMED AS REQUIRED.


(2)-24-C-1000-P460-T200
15 P.)
(T

0
Y

15 P.)
(T

150 150
Y

T.O.C. EL. 2745.909

LAST EDIT: 11/5/2021 10:17:08


300
ANCHOR BOLT PLAN FOR 610UB EMBEDS UNDERGROUND - GBC
SCALE: 1 : 100 GBC CRUSHER 23-CR-0603
REV.No DATE BY REVISION NOTES. REV.No DATE BY REVISION NOTES. DRAWING REFERENCES:
ISSUED FOR : CONSTRUCTION CRUSHER FOUNDATION
02022918-GC-00000001 CONCRETE STANDARDS GENERAL NOTES AND ANCHOR BOLT DETAILS FCX DRAWING NUMBER : MIDDLE LAYER REBAR PLAN, SECTIONS AND DETAILS
23270020-GC-O9260049 CRUSHER FOUNDATION PLAN, SECTIONS AND DETAILS
23270020-GS-O9260057 CRUSHER FOUNDATION EMBEDDED STEEL PLAN, SECTIONS AND DETAIL
GBC603-DD-O926-CIV-DWG-0051 Designed KJY 19AUG21 SCALE: SHOWN EWP: C603C.2A

23270020-GS-O9260058 CRUSHER FOUNDATION EMBEDDED STEEL SECTIONS AND DETAILS DISCIPLINE LEAD FMI DISCIPLINE LEAD AREA MANAGER ENGINEERING MANAGER Drawn KML 30JUN21 PTFI DRAWING NUMBER REV.

JOEL S. DORSA NEIL MARINELLO KODY KIRCHNER STEVEN L. MITCHELL Checked BLW 19AUG21

26OCT21 01NOV21 02NOV21 05NOV21 Approved JSD 20AUG21


23270020-GC-O9260051 0

You might also like