Classification of hazard\n7. Means of egress\n8. Features of fire protection\n9. Building service and fire equip\n10. Interior finish & contents Performance based/ special structures Chapter 5\chapter 11 New and existing 12/13. assembly\n14/15. educational\n16/17. day care\n18/19. health care\n20/21. ambulatory health care\n22/23. detention/ correction\n24. 1–2 residential\n26. lodging /recovery homes\n28/29. hotel and dorm\n30/31. apartment \n32/33. residential board\n40. industrial\n42. storage\n Navigation Occupancy classification – ch.6\new or existing– Definitions\Occupancy load– ch. 7.3\hazard content– ch.6 If mixed assembly then Use the strictest guidelines Subsections XX.1–General requirements\nXX.2–Means of egress\nXX.3–Protection\ nXX.4–Special provisions\nXX.5–Building services\nXX.6–Reserved\nXX.7–Operational features Ch. 1 Administration Ch.2 Reference Ch. 3 Definition Ch.4 General Ch. 6 Classification of Hazards Ch.7 Means of egress Ch. 8 Features of fire protection Ch. 9 Building services and fire equipment Ch. 10 Interior finish and content XX.1 General XX.2 Means of egress XX.3 Protection XX.4 Special Provisions XX.5 Building services XX.6 Revised XX.7 Operational features Soiled trash holding capacities Less than or = to 32 gallons Soiled trash holding capacities in hazard room Greater than 32 Greater than 2000 56" Less than 2000 44" Max smoke compartment size 22,500 NFPA code for helicopter NFPA 418 Corridor separation 18.3.6 21.7.5.4 combustible decor shall be prohibited unless Meets NFPA 701\exhibits a heat release rate no greater than 100kW NFPA 289\Pics and paints allowed in limited quantity 21.7.8 portable heaters prohibited in ambulatory health unless Used in non-sleeping areas\heating element doesn’t exceed 212F 100C Drills shall be conducted Quarterly on each shift Drills conducted 0900pm– 6am Code announcement shall be permitted to be used instead of audible alarms Latching hardware shall not be required On smoke barrier cross corridor and door shall not be required to swing in direction of egress Smoke barriers shall have minimum of Half hour fire ratings unless permitted in 21.3.7.6 Fuelled fire heating device shall comply with all the following Chimney connected or vent connected\take air from combustion to outside\designed to provide complete seperation of combustion system Approved suspension unit heaters shall be permitted in locations other than means of egress if both apply Located out of reach of person using area\n \equipped w safety features .. Alcohol hand rub shall be protected unless Dispensers are installed in corridor min width 6ft\n \n.32 gals for dispensers in rooms and corridor\n \n.53 gals for dispensing in suits and rooms\Aerosol containers max cap 18oz. \NFPA 30B\ All building below one level of exit discharge Type II (111) Clear width of corridor for exit access shall not be less than 44in Major renovation More than 50% or 4500 ft Minor rehabilitation shall involve Not more than 50% and no more than 4500 ft Any required aisle, corridor or ramp shall not be less than 48in Sleeping rooms of more than 1000ft shall not have Less than 2 exit doors remotely located from each other Non sleeping rooms more than 2500ft shall not have Less than 2 access remotely located from each other Exit sign illumination and visible sight distance 100ft Medical gas storage NFPA 99 Fixed extinguisher system protecting commercial cooking equipment in kitchen are protected by complete automated sprinkler system shall not require To initiate the fire alarm system Corridor walls shall Form a barrier to limit the smoke transfer Doors to toilet, shower, sink, auxiliary spaces that do not contain flammable or combustible material shall be permitted to have Ventilation louvers or be undercut Aisle corridor and ramps required for exit in hospital or nursing home shall not have less than 8ft in clear unobstructed width Eye wash station is required how far must it be from injurious corrosive Material 55ft or 10 secs Nfpa 99 adopted in 2012 Joint commison surveys every 3 yrs We must divide existing ambulatory health occupany under 5000sqft into no less than 2 smoke compartments True For NO EXIT, NO shall be 2in, 1in How many cubic feet of compressed gas do you need before the room housing it is required to be rated 3000 cubic sqft How many cubic feet of gas is in an e cylinder 23 cubic ft Fire extiguishers under 40lbs min distance off floor 4in Non patient transport corridor width shall be no less than 44in Vertical opening 4 stories or more are required to be enclosed at what fire resistance rating 2hr Vertical openings 3 stores or less require... 1hr What is required for fire/smoke damper to be omitted in smoke barrier in healthcare Fully ducted HVAC Minuim distance of a wall a sprinkler head should be 4in Percentage of fire door face can be used for signage 5% What is minimum dead corridor limit in HC 30ft Common path of travel shall not exeed 100ft Max height window sill 36 Doors shall be BLANK in thick with a BLANK min fire rating Vision panel required inBLANK doors 1.75, 20, swinging Fire extingishers shall be checked BLANK by a qualifited person and servixed BLANK by examiner\n Quarterly\nAnnually Hand fire extingushers are required on every floor and in every Hazardous area Smoke detectors shall be no father than BLANK ft and no more than BLANK from any wall. They should also be connected 30, 15, electrically Emergency generators must go on within 10 secs Exit signs must be visable Every direction Travel distance to exit in a room must not exceed 50 ft Travel distance to exit between any patient room and exit must not exceed 200 ft Travel distance to exit between doors in any room and exit must not exceed 150 Max rise in single ramp 30" Max slope in ramp 1inch in 12 inches Ramps require a clear width of at least 44 inches Ramps less than BLANK degrees = Ramp 7 Ramps BLANK to BLANK degrees = stairway + landing 7, 20
The Complete HVAC BIBLE for Beginners: The Most Practical & Updated Guide to Heating, Ventilation, and Air Conditioning Systems | Installation, Troubleshooting and Repair | Residential & Commercial