DESIGN OF 300 KL CAPACITY CWR AT PS2, NEAR BAPLIYAN

Given Data :-
2
1 Grade of Concrete M-30 fck 30 N/mm
2
2 Grade of Steel M-500 fy 500 N/mm
2
3 Safe Bearing Capacity at 1.25 m 70 KN/m
3
4 Unit wt. of Liquid W 10 KN/m
3
5 Unit wt. of Soil gs 18 KN/m

:- Reference :-
I.S. 456 - 2000
I.S. 3370 PART-1 : 2021
I.S. 3370 PART-2 :2021
I.S. 3370 PART-4 :2021

:- Minimum Clear Cover to Reinforcement :-

Sr. No. Member Not in contact with in contact with Soil or


1 Slab 20 45
TOP 30 45
2 Beam
BOTTOM 30 45
3 Column & Pedestal 40 45
TOP 50 50
4 Column Footing / Pile Caps
BOTTOM 50 50
5 Walls 45 50
TOP 50 50
6 Wall Footing
BOTTOM 50 50
TOP 50 50
7 Raft
BOTTOM 50 50

:- Calculation of Development Length ( Ld ) :-


M - 30
Ø x 0.87 x fy 8 x 0.87 x 500
Ld = = = 363 mm
4 x tbd 4 x 1.5 x1.6

Bar Dia. Req. Development Length ( Ld ) Pro. Development Length ( Ld )


#8 363 370
# 10 453 460
# 12 544 550
# 16 725 730
# 20 906 910
# 25 1133 1150
# 32 1450 1450
DESIGN OF TOP DOME :-

Clear Span of Top Dome 9.8 m


Rise of Lower Face of Top Dome 1.4 m
Thickness of Top Dome 150 mm = 0.15 m
Radius of Lower Face of Dome:-

2 2
D/2 + r 4.9^2 + 1.4^2
R = = = 9.275 m
2r 2 x 1.4
3
Unit Wt. of Concrete 25 KN/m

2
Self Load of Dome 0.15 x 1.00 x 1.00 x 25 = 3.75 KN/m
Live Load = 2 KN/m2
Finishes = 0 KN/m2
Toatl Load (Q) = 5.75 KN/m2

Cos Ø = (9.275-1.4)/9.275 = 0.849


Sin Ø = 0.528
Ø = 31.89 Degree
< 51 Degree
Therefore, The Dome is in Compresion Throughout

Maridianal Thrust at Edge :-

Qx R 5.75 x 9.275
T = = = 28.842 KN/m
1+ CosØ 1 + 0.849

Factored Maridianal Thrust at Edge (T) = = 43.264 KN/m

Maridianal Stress at Edge :- 43.264


= 0.29 N/mm2
0.15 x 1000
2
< 13.38 N/mm
Safe

2
Circumferential Force at Crown Cos Ø + CosØ -1
wR
(Ø = 0 ):- 1 + CosØ

1+ 1 -1 2
= 5.75 x 9.275 x = 26.67 N/mm
1+1

Factored Circumferential Force 2


= = 40.00 N/mm
at Crown (Ø = 0 ):-

Hoop Stress at Crown :- 39.998 2


= 0.27 N/mm
0.15 x 1000
2
< 13.38 N/mm
Safe
Both the max. Stresses are Compressive and within Limits Hence min. Temp. Reinf. @ 0.24% of Gross
Sectional Area shall be Provided as per the Thickness of the Dome Adopted.
Temp. Reinf. Required = 0.24 %

2
Area of Reinf Required :- 0.24 % x 150 x 1000 = 360 mm
Area of Reinf Provided :-
2
#8 @ 125 C/C = 402.1 mm

Hoop Tension at Edges due to Continuity = -45.6 KN


2
Steel Required for Hoop Force = 248.6 mm
1.5*ABS(-45.57)*1000/275
Required No. of Bar = 4.95 Nos.

Provided No. of Bar :- 6- #8 Safe

BM at Edges Due to Continuity = -2.53 KN-m

2
Area of Steel Reqd. for Moment = 58.5 mm

Area of Reinf Provided :-


2
#8 @ 150 C/C = 335.1 mm
Vert. Bars of Outer Face of Wall shall be Ext. in Dome for a Length of 1200 mm as Radial Bars

DESIGN OF TOP RING BEAM :-


Internal Diameter of the Beam = 9.8 m
Horizontal Component of Thrust from Dome = 24.489 KN/m
Hoop Tension at the Edges = 24 x 9.8 / 2 = 119.995 KN

Hoop force at the junction (From continuity anal.) = -26.53 KN

2
Area of Steel Reqd. for the Hoop = 654.52 mm
1.5 x 120 x1000/0.55 x500
Required No. of Bar = 5.79 Nos.

Provided No. of Bar :- 0- #0 + 6- # 12 Safe

2
Area of Concrete Required :- Ac = 1.5*(Ft/σct)-(m-1)*Aspro. = 41293.2 mm

2 2
sct = 3.83 N/mm sst = 275 N/mm m = 9.33

Adopted Size of Beam:-


Top Ring Beam Width = 0.3 m
Top Ring Beam Depth Required = 0.14 m
Top Ring Beam Depth Provided = 0.3 m

2
Area of Concrete Provided :- = 90000 mm
Safe
Provide 2 legged stirrups of #8 @ 150 C/C