DRAWINGS

1. Tank Arrangement Drawing

2. Foundation Guidance Drawing

3. Access Manway Detail

4. Tank Bolt Detail

5. Tank Connector Detail

6. Sheet Detail

7. Straight Seam Detail

2
 

REMOVE SHARP IF IN DOUBT WELD METHOD MUST


10 20 30 40 50 60 70 80 90 100 DRAWING SCALE (mm) DO NOT SCALE CN No REVISION ISS
PART No QN43253-1-APP EDGES  ASK  ENSURE MINIMUM DISTORTION & DATE No

 FINISH NOTES:
1. TANK SHEETS TO BE FINISHED ISOFUSION GRADE
EXTERNAL COLOUR: BLUE 20-C-40
INTERNAL COLOUR: BLUE/GREEN 14-C-40
2. TOP STIFFENER FINISH: GALVANISED MILD STEEL
3. FOUNDATION ANGLE FINISH: PRIMER PAINTED
4. WIND STIFFENER ASSEMBLY FINISH: GALVANISED MILD STEEL
30no VERTICAL
5. GALVANISING SPECIFICATION: BS EN ISO 1461
BOLT SEAMS
INSIDE TANK DIAM.

1
2"
DIAMETER
GALVANISED STORE
BOLT WITH PLASTIC
NUT COVER
   R CAPPED HEAD
   E COLOUR BLACK
   T
   E PART No 566155
   M SIKA TS+ SEALANT
   A
   I COLOUR BLACK
   D
   K
   N
   A ENLARGED SECTION THROUGH
   T  
   L HORIZONTAL/VERTICAL SHEET JOINT
   A
   N
   I
SHOWING SHEET/BOLT SEALANT APPLICATION
   M
   O
   N GALVANISED ACCESS
   6 LADDER AND 1m x 1m
   1
   6 PLATFORM
   5
   2

TANK DIAM.

30x30 SEALANT FILLET, CONCRETE


UNDER SEALANT TO BE PREPARED WITH
INFILL CONCRETE PLACED
PRIMER PRIOR TO APPLYING FILLET
 AFTER TANK ERECTION.
C35 MIN. CEMENT CONTENT
CIVIL CONTRACTOR TO ENSURE
  
MAX. 80mm SLUMP MAX. THAT THE INTERNAL VERTICAL
FACE OF THE REBATE IS
PREPARED OR TREATED TO
FOUNDATION 250 100
PROMOTE AN EFFECTIVE BOND
 TANK DESIGNED FOR: CLAMP WITH THE INFILL CONCRETE
   T    E   E
   H   S    S   L SG = 1.05
   A
   G
   I    E    B   G
   N WIND SPEED = 50m/s
   E   L    A 150
   H   G    F SPECIFIED LEVEL OF REBATE
   O   F
   K   N
   
   A    P   O
   N
   A   R    O    P
   T   E    T   O
   0   V    5   T     5 WIND STIFFENER 200 HYDROPHILICSEAL
   9   O    6   O   5
   6    5   ASSEMBLY
   5    5   T
25mm MIN. SHIMS

FOUNDATION BOLT

200
CIRCUMFERENTIAL REINFORCING
BAR EXCLUSION ZONE

CONFIDENTIAL COPYRIGHT RESERVED



   5    5
   2    3   NO UNAUTHORISED COPYING OR EXHIBITING
   1
CAD DRAWING - NO MANUAL ALTERATIONS PERMITTED

TOLERANCES UNLESS 
DRAWN RDP DATE 4.6.15 MATERIAL - DESCRIPTION MODEL 8420 BALANCING TANK
OTHERWISE STATED -
LINEAR (EXCEPTS STOCK 
SIZED & DRILLED HOLES)
SCALE NTS CHECKED MATERIAL SPEC - USAGE SUIDO KIKO MIDDLE EAST
Permastore Ltd
     Eye, Suffolk 
     ISSUED EXP No FINISH - IP23 7HS, England REF SUDAIR, SAUDI ARABIA
     Tel (01379) 870723
     Fax (01379) 870530
  
1
2 DEG
THIRD ANGLE PROJECTION

PART No QN43253-1-APP
PERMASTORE is a registered trademark of Permastore Ltd
 

REMOVE SHARP IF IN DOUBT WELD METHOD MUST


10 20 30 40 50 60 70 80 90 100 DRAWING SCALE (mm) DO NOT SCALE CN No REVISION ISS
PART No QN43253-2-APP EDGES  ASK  ENSURE MINIMUM DISTORTION & DATE No



34no VERTICAL FINISH NOTES:


BOLT SEAMS 1. TANK SHEETS TO BE FINISHED ISOFUSION GRADE
EXTERNAL COLOUR: BLUE 20-C-40
INTERNAL COLOUR: BLUE/GREEN 14-C-40
2. TOP STIFFENER FINISH: GALVANISED MILD STEEL
3. FOUNDATION ANGLE FINISH: PRIMER PAINTED
4. WIND STIFFENER ASSEMBLY FINISH: GALVANISED MILD STEEL INSIDE TANK DIAM.
5. GALVANISING SPECIFICATION: BS EN ISO 1461

1
2"
DIAMETER
GALVANISED STORE
BOLT WITH PLASTIC
NUT COVER
CAPPED HEAD
COLOUR BLACK
   R PART No 566155
   E
   T SIKA TS+ SEALANT
   E GALVANISED ACCESS
   M COLOUR BLACK
   A
   I
LADDER AND 1m x 1m
   D PLATFORM
   K
   N ENLARGED SECTION THROUGH
   A HORIZONTAL/VERTICAL SHEET JOINT
   T  
   L SHOWING SHEET/BOLT SEALANT APPLICATION
   A
   N
   I
   M
   O
   N
   2
   3
   0
   9
   2
TROUGH DECK ROOF

TANK DIAM.

30x30 SEALANT FILLET, CONCRETE


UNDER SEALANT TO BE PREPARED WITH
INFILL CONCRETE PLACED
PRIMER PRIOR TO APPLYING FILLET
 AFTER TANK ERECTION.
C35 MIN. CEMENT CONTENT
   CIVIL CONTRACTOR TO ENSURE
MAX. 80mm SLUMP MAX. THAT THE INTERNAL VERTICAL
FACE OF THE REBATE IS
PREPARED OR TREATED TO
FOUNDATION 250 100
PROMOTE AN EFFECTIVE BOND
CLAMP WITH THE INFILL CONCRETE
TANK DESIGNED FOR:
SG = 1.05
WIND SPEED = 50m/s 150 SPECIFIED LEVEL OF REBATE

   
   5 WIND STIFFENER
   5 
 ASSEMBLIES

200 HYDROPHILICSEAL

   T    E   E 25mm MIN. SHIMS


   H    S   L
   S    A   G
   G
   I    E    B   N
   E   L    F   A
   H    G FOUNDATION BOLT
   N    O
   K   A
   F
   N    P   O
   A   R    O    P 200
   T   E    T   O
   0   V    5   T  CIRCUMFERENTIAL REINFORCING
   9   O    6   O
   4    3 BAR EXCLUSION ZONE
   8    8   T

CONFIDENTIAL COPYRIGHT RESERVED



   5   5
   2   3  
   1 NO UNAUTHORISED COPYING OR EXHIBITING
CAD DRAWING - NO MANUAL ALTERATIONS PERMITTED

TOLERANCES UNLESS 
DRAWN RDP DATE 4.6.15 MATERIAL - DESCRIPTION MODEL 9530 TREATED WATER TANK
OTHERWISE STATED -
LINEAR (EXCEPTS STOCK 
SIZED & DRILLED HOLES)
SCALE 1:200 CHECKED MATERIAL SPEC - USAGE SUIDO KIKO MIDDLE EAST
Permastore Ltd
     Eye, Suffolk 
     ISSUED EXP No FINISH - IP23 7HS, England REF SUDAIR, SAUDI ARABIA
     Tel (01379) 870723
     Fax (01379) 870530
  
1
2 DEG
THIRD ANGLE PROJECTION

PART No QN43253-2-APP
PERMASTORE is a registered trademark of Permastore Ltd