KEY PLAN :

RD 09 N

C20

GENERAL NOTES :

3000

3000
1. THIS DRAWING IS NOT TO BE SCALED.
2. ALL DIM. ARE IN MILLIMETERS AND ALL LEVELS ARE IN METERS.
3. SHORING SYSTEM IS TEMPORARY SOLDIER BEAM AND LAGGING BY RC PANELS.
4. SHORING DESIGN IS BASED ON SOIL REPORT REF NO:AS/GI19/404 , REV-0 DATED
(01-10-2019) RECEIVED FROM GEOTECH FOR SOIL INVESTIGATION LABORATORY.
150 GROUND LEVEL
150 GROUND LEVEL
5. SHORING DRAWING IS BASED ON EXCAVATION LAYOUT REV-0 DATED (28-10-2022)
RECEIVED FROM MAIN CONTRACTOR.
6. PRE-CAST CONCRETE PANELS - CONCRETE GRADE 25 MPA FOR REINFORCEMENT :
-0.81 m -0.81 m Fy = 460 N/mm2.
7. GRADE OF STEEL BEAM MEMBER AND SHEET PILE: Fy =355N/mm2.
SOIL PROFILE SOIL PROFILE 8. PRE EXCAVATION TO BE CARRIED OUT THE EXISTING GROUND LEVEL TO REACH THE
50 MEDIUM DENSE SAND 50 MEDIUM DENSE SAND
SITE TILL LEVEL -0.81m BEFORE INSTALLATION OF SHORING BEAMS.

N=16, Ø=32°, Ɣ=16 KN/m³ N=16, Ø=32°, Ɣ=16 KN/m³

SECOND SOIL LEVEL SECOND SOIL LEVEL


-1.50 m -1.50 m

4500

5000
01 17/01/2023 ISSUED FOR APPROVAL

00 08/11/2022 ISSUED FOR APPROVAL

SANDSTONE SANDSTONE REV. NO DATE DESCRIPTION


MAX EXCAVATION N>50 N>50
LEVEL -5.31m Ø=40° Ø=40°
9000

9000
OWNER :
Ɣ=19 KN/m³ MAX EXCAVATION Ɣ=19 KN/m³
LEVEL -5.81m QADHEEB HAMAD SAIF AL AWANI
C=100 KN/m2 C=100 KN/m2
PM :

CONSULTANT :

Y Y Y Y

TOE LEVEL TOE LEVEL MEP CONSULTANT :

-9.81 m THIRD SOIL LEVEL -9.81 m THIRD SOIL LEVEL


-10.00 m -10.00 m
308 308

MAIN CONTRACTOR :
SECTION (1-1) SECTION (2-2)
SCALE 1:50 SCALE 1:50

GROUND WATER TABLE -23.70 m


SUB CONTRACTOR :
FROM SOIL REPORT REF:AG/GI19/404

PROJECT NAME :

RESIDENTIAL BUILDING
ZONE :
MADINAT AL RIYAD, ABU DHABI, UAE
SECTOR NO : PLOT NO :
RD 09 C20
PROJECT DESCRIPTION :

PROPOSED COMMERCIAL DEVELOPMENT


BASEMENT, GROUND, FIRST, 4 TYPICAL & ROOF FLOOR
EARTH SIDE
MAIN REINFORCEMENT T10@ 200 mm
A DRAWING TITLE :
SECONDARY REINFORCEMENT T10@ 200 mm 305.3
2000 UC 305x305x97 kg/m
100
REINFORCEMENT

OR Equivalent
T10 @ 200 mm

SHORING SECTIONS & DETAILS


SECONDRAY

1950
B B 9.9
1000

100mm THK.

307.9
PRECAST PANEL
50

15.4
PLOT LIMIT Drawing Status :
T10 @ 200 mm
50mm THK. SHOP DRAWINGS
BASEMENT LIMIT TOLERANCE
MAIN REINFORCEMENT Drawing No : Revision :
A 150mm THK. INEX-2207-C20-SD-STR-051 02
100

SEC A-A BLOCK WORK


Project No : Project ID :
EXCAVATION SIDE
UC 305x305x97 Kg/m G355 OR Equivalent --- ---
T10 @ 200 mm T10 @ 200 mm
Drawing Scale : Drawing Size :
1950 TYPICAL DETAIL FOR SHORING BEAMS AS SHOWN A1
SEC B-B SCALE 1:20 SEC (Y-Y) Drawn By : Checked By :
SCALE 1:10 I.F A.A
TYPICAL DETAIL FOR PRE-CAST PANELS Sheet No : Date :
SCALE 1:20 1 OF 1 17-01-2023

A APPROVED.

Notes:- B APPROVED AS NOTED.

-Use steel rebars form certified factories in Abu Dhabi. C RESUBMIT FOR APPROVAL.

D REJECTED.