A C1 C2 C1 A
FOOTING SCHEDULE (M25:Fe500) TO BE CLARIFIED FROM AUTHORITY CONCERNED.
3. DO NOT SCALE DRAWING, FOLLOW ONLY WRITTEN
FOOTING DIMENSION FOOTING REINFORCEMENT
FOOTING FOOTING DIMENSIONS.
BOTTOM TOP
REMARK RCC :
214 NUMBERS TYPE STEP L B D1 D2
ALONG SHORT SP. ALONG LONG SP. ALONG SHORT SP. ALONG LONG SP.
01. GENERAL GRADE OF REINFORCED CONCRETE M-25
1980
1980
F1 ISOLATED - 2700 2400 450 - 16T@125 C/C 16T@125 C/C - - (NOMINAL)
2400
2700
2800
F2 ISOLATED - 3500 2800 600 - 16T@100 C/C 16T@125 C/C - - & OF P.C.C. IS M-10 UNLESS OTHERWISE STATED, WITH W/C
F3 ISOLATED - 2400 2100 400 - 16T@150 C/C 16T@150 C/C - - RATIO OF 0.50.
C3 C3 F4 ISOLATED - 2700 2400 450 - 16T@125 C/C 16T@125 C/C - - 02. CEMENT :
A) USE 53-GRADE O.P.C. CONFIRNING TO IS-2269.
B B F5 ISOLATED - 3800 3500 650 - 16T@100 C/C 16T@100 C/C - -
1771
3500 F8 ISOLATED - 3600 2900 600 - 16T@100 C/C 16T@100 C/C - -
BEAM &
F9 ISOLATED - 2950 2950 600 - 16T@100 C/C 16T@100 C/C - - COLUMNS 12.5 MM & DOWN FOR SLAB & SUCH THIN
SECTIONS.
C3 C3 04. REINFORCEMENT : HYSD BARS OF GRADE Fe500 CONFIRMING
C C TO IS-1786-1985
* WELDING OF BARS WITH PERMISSION OF STRUCTURAL
2400 2400 ENGINEER
1380
1380
* DEVELOPMENT/LAPPING LENGTH OF BARS (C=50Ø AND T =
(TYP) (TYP) 55Ø)
3500
2700
2700
Y
Y
COLUMN - 40 MM (SIDES)
BEAM R/F BEAM R/F SLAB - 15 MM (SIDES) 25 MM (BOTTOM & TOP)
340
600
BEAM - 25 MM (TOP & BOTTOM)
600
NOT SHOWN NOT SHOWN
05. CURING PERIOD FOR RCC - 14 DAYS
06. STRIPPING TIME OF FORM WORK FOR RCC- AS DECIDED BY
X
X
F4 3800 F5 F4 SITE
600
600
ENGINEER IN ACCORDANCE WITH IS-456/2000.
4013
4013
07. REINFORCEMENT OF ALL THE CONCRETE ELEMENTS
R.C.C. BEAM R.C.C. BEAM SHOULD
2700 2700 BE GOT APPROVED BEFORE CASTING.
Y
Y
08. ANY DISCREPANCY IN FIELD DIMENSION SHOULD BE GOT
CLARIFIED FROM THE CONSULTANTS.
BEAM R/F BEAM R/F
09. PLEASE CHECK THE DIMENSION WITH RESPECT TO
NOT SHOWN NOT SHOWN
C5 C6
600
600
ARCHITECTURAL PLANS BEFORE EXECUTION.
3100
3100
X
X
SEEK CLARIFICATION FROM CONSULTANTS.
E E 11. THE BUILDING FOUNDATION IS DESIGNED FOR
G+1+2+3+4+TERRACE
MAIN R/F OF COL. MAIN R/F OF COL. FLOOR FLOOR ONLY.
R.C.C. BEAM R.C.C. BEAM 12. THE EXCAVATED AREA OF PLINTH/FOUNDATION TO BE
REFILLED WITH MURRUM/GOOD ENGINEERING EARTH.
Y
Y
F6 F6 BEAM R/F BEAM R/F
13. COMPACT THE MURRUM TO GIVE A FIELD DENSITY OF 60-62
KG/CFT. (2.3GM/CC),
600 600
600 600
3251
3251
NOT SHOWN NOT SHOWN 14. MINIMUM SAFE BEARING CAPACITY OF SOIL FOR
FOUNDATION
X
X
MUST BE 200 KN/SQM. AT 3.0 M DEPTH.
2600 2600 15. DEPTH OF FOUNDATION UPTO HARD BASE OR MINIMUM 2.5M
FROM NGL
Y
Y
16. REFER ARCHITECTURAL DRAWINGS FOR ALL LEVEL.
F
C7 C8 F TYP. FOO. TYP. FOO.
400
2900
2900
300
X
X
300 600
2950
4775
114
ARCHITECTS & ASSOCIATES
2900 2900 BAR L-DIR. BAR L-DIR.
201-D, VIDYAPATI, 17, RACECO. ROAD,
F9 JANJIRWALA SQ. INDORE (M.P), 452002.
(Shorter Side)
(Shorter Side)
S
S
3600
3600
a
CONTACT: 8878955000
a
G G b b
SIDDI VINAYAK ASSOCIATES
L L CONSULTING STRUCTURAL ENGINEERS
(Longer Side) (Longer Side) 6,Dewas naka near kasliwal Hyundai Indore
PHONE: 9754219875,8109680848
F8 F8 E-MAIL : siddivinayak2020@gmail.com
TYPICAL DETAIL OF FOOTING TYPICAL DETAIL OF CORNER FOOTING
4572 1741 2826
1 2 3 4