Professional Documents
Culture Documents
Steady State Considerations in Vapor Intrusion Study Design
Steady State Considerations in Vapor Intrusion Study Design
VAPOR
INTRUSION
WHITE PAPER
Vapor intrusion (VI) is a potential exposure pathway at The evaluation of VI often involves determining concen-
contaminated sites that involves the migration of volatile trations of volatile organic compounds (VOCs) in shallow
chemicals from soil or groundwater into overlying build- soil gas and/or indoor air. Sampling is generally expected
ings. Guidance for VI investigations has been published in to be performed under steady-state, representative
the U.S. by the United States Environmental Protection conditions. In this context, steady-state means that the
dependent variable is not changing with time or over time.
Agency (USEPA, 2015a; USEPA, 2015b) and by 42
In this paper, steady-state generally refers to vapor-phase
States (Eklund, Beckley, and Rago, 2018). The guidance
concentrations remaining constant over a specified time
documents generally set forth procedures that have the
frame of interest.
goal of collecting data that are representative of average,
long-term conditions or are biased high (i.e., biased toward
worst case), with a strong preference for avoiding low
bias. This is consistent with the USEPA’s recent focus on This white paper examines the basis for various
indicators, tracers, and surrogates (ITS) for VI, which also approaches often followed in contemporary vapor
has a preference for high bias. This is reasonable, given
intrusion guidance. Where possible, recommendations
that VI investigations tend to involve relatively small data
are made to improve the current standard practice.
sets, and important risk management decisions regarding
potential inhalation exposures may be based on only a few
data points.
www.haleyaldrich.com
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
At steady-state conditions, the system is stable. For example, 1) How long do you need to wait to collect an indoor air sample
VI is said to be at “steady-state” when the amount of mass after removing a potential indoor air emission source?
entering the vapor phase in the soil due to volatilization is
equal to the mass of VOCs migrating through the subsur- 2) How long should you wait to collect an indoor air sample
face at any soil layer between the vapor source and the after adjusting the heating, ventilation, and air conditioning
atmosphere. Steady-state conditions differ from chemical (HVAC) system?
equilibrium in terms of thermodynamics; a system at steady-
3) How long should you wait to sample after turning off the
state may have energy inputs and be maintained at a higher
HVAC system?
Gibbs-free energy state than at equilibrium.
4) Should the collection times for outdoor air samples be
When a system at steady-state is perturbed, the system
simultaneous with indoor air samples?
reacts and eventually reaches a new steady-state. While
this adjustment is taking place, the system is said to be in 5) What collection times for soil vapor samples and indoor air
a transient state. Testing under transient conditions typi- samples are effectively concurrent?
cally should be avoided because the data collected may
be neither representative nor reproducible. Therefore, VI 6) What sampling duration should be employed for soil vapor
guidance often includes explicit assumptions about how samples? How long do you need to wait to sample after a
long it takes for steady-state conditions to be established new probe or well is installed?
after a system is perturbed (e.g., how long to wait to sample
7) How long should you wait after soil vapor extraction (SVE)
after installing a probe or removing an indoor air emission
system shutdown to ensure representative soil vapor data?
source). VI guidance also often includes implicit assump-
tions about chemical kinetics (which are assumed to be very 8) How long should you wait for biodegradation processes to
slow) and phase partitioning (which is assumed to be essen- be established?
tially instantaneous). This translates to VI guidance that is
prescriptive but based on flawed assumptions regarding
what is required to avoid transient state, or alternatively DISCUSSION
– completely silent – in defining when sampling should be
Each of the questions listed above is discussed in turn below.
conducted to capture steady- state conditions. Either way,
In each case, recommended guidance is provided that is
it is important to consider the rate of change when exam-
an improvement and a defensible alternative to existing
ining the time required for a new steady-state condition to
published guidance.
be become established after a system is perturbed. This
paper addresses a series of questions that concern timing
of sampling to avoid transient conditions in VI assessments
and provides recommendations for improved VI assessment
practices that are based on sound science.
www.haleyaldrich.com PAGE 2 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
USEPA: In residential settings, EPA generally recom- The inverse happens when we remove an indoor air emission
mends that potential indoor sources be removed from source from a building; it takes some time for the concentration
the structure and stored in a secure location at least in the indoor air to decay to the new steady-state concentra-
24 to 72 hours prior to the start of sampling, based tion. The changes in concentration within a CSTR are well
on an approximate air exchange rate of 0.25 to 1.0 air understood based on both theory and empirical data. The
changes per hour in residential settings. concentration changes exponentially as a function of time after
(Eq. 1)
the system is perturbed or changed:
www.haleyaldrich.com PAGE 3 OF 15
(Eq. 4)
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
www.haleyaldrich.com PAGE 4 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
www.haleyaldrich.com PAGE 5 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
Topic #3 – Turning off building HVAC dilution air but also lower rates of vapor infiltration, it is diffi-
cult to predict which process will predominate and whether
An extreme example of a change in building ventilation is
indoor air concentrations will exhibit a net increase or a net
turning off the HVAC system and any exhaust or ventilation
decrease versus baseline conditions.
fans. How long should you wait to sample after shutting
off the building ventilation if characterization of indoor As noted above, the waiting times for steady-state condi-
air under unventilated conditions is desired? Obviously, it tions to be achieved may be up to four days for a well-sealed
will take longer for the system to stabilize and reach a new building (e.g., 0.05 ACH). Asking building occupants to do
steady state in this scenario than in the scenarios previously without ventilation for that period of time is not reasonable.
discussed, because as shown in Equation 2, Tau is inversely One option that practitioners may consider is to not wait for
related to the rate of ventilation. A lower bound ventilation steady-state conditions and instead collect indoor air samples
rate for an unventilated, closed space is thought to be about after some fixed time period after the HVAC is shut off, while
0.05 ACH. That is the 5th percentile value for newer single- the system is in a transient state. As noted above, sampling
family houses (USEPA, 2018). If that value applies, there is during such transient conditions may yield ambiguous results.
about one air change per day, and a four-day waiting period is
needed before steady-state conditions are achieved. There- Collecting indoor air samples long before the new steady state
fore, four days would be the optimal waiting time to sample an is achieved increases the likelihood that the change in indoor
office building or other well-sealed building. A typical single- air concentration versus baseline concentration will fall within
family house would likely have more ventilation due to leakage the measurement variability. Typical analytical methodology
around doors and windows. Assuming 0.1 ACH, a 48-hour uncertainty is about ±30 percent for most target compound
waiting period would be sufficient. list VOCs based on laboratory control checks. Unless the
HVAC-on and HVAC-off concentrations are substantially
different from one another, the two results may fall within
this range of uncertainty and complicate evaluation of the
In our opinion, collecting indoor air data when the effects of HVAC operations on indoor air quality. The same
building HVAC is shut off as a routine element of a may be said when both results approach the method reporting
VI study may be misleading. limit where precision and accuracy may suffer and analytical
uncertainty is greater.
In some guidance documents (e.g., USEPA, 2015a), there
may be recommendations to turn off any HVAC system and Lastly, it also should be recognized that the usual assumption
collect samples under supposed “worst-case conditions.” In that the indoors is a well-mixed space may not hold true with
reality, there may be competing processes, and unventilated the shutdown of HVAC or other building ventilation. There
conditions may not be representative of worst-case condi- likely will be greater stratification in air concentrations within
tions. It depends on whether operation of the HVAC system the building, making it more difficult to assess whether the
typically results in positive or negative pressure within results that are obtained are representative of a larger area.
the building relative to the subsurface. Whereas turning
Although sampling in non-residential settings with the
off the HVAC greatly reduces the building ventilation and
HVAC off is recommended in some guidance documents, in
decreases dilution of any vapors that enter the building, the
the opinion of the authors, collecting indoor air data when the
lack of operating ventilation fans may change the pressure
building HVAC is shut off may be misleading. Multiple lines of
differential across the building slab. If the building is typi-
evidence should be used in data reduction when employing
cally positively pressurized, turning off ventilation fans will
this as a routine element of any VI study. If there is a need to
increase the rate of VI and will tend to increase the indoor air
augment data collected under potential worst-case conditions,
concentrations, further reinforcing the trend due to lesser
an option would be for practitioners to manipulate the building
diluent air. If the building is typically negatively pressurized,
pressure to directly determine the effect of that variable on
turning off fans will decrease the rate of vapor intrusion and
measured indoor air concentrations.
will tend to decrease the indoor air concentrations (e.g., a
restaurant kitchen with exhaust hoods). When there is less
www.haleyaldrich.com PAGE 6 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
Topic #4 – Timing of outdoor air samples samples (i.e., the length of a typical work shift). The sampling
duration for outdoor air samples should match whatever
Given the air turnover rates in typical buildings, the indoor
sampling duration is used for the indoor air samples. In most
air is routinely replaced with outdoor air every hour or two.
cases, that means collection of 24-hour outdoor air samples
Therefore, whatever VOCs are present in outdoor air will
for residential buildings and 8-hour outdoor air samples for
tend to find their way into the indoor space. The indoor (I)
non-residential buildings such as offices, factories, shops,
and outdoor (O) values can be compared to evaluate what
stores, and schools.
fraction of the indoor air concentration originates from
outdoor sources versus VI or indoor emission sources. An Outdoor air samples are generally collected concurrently
I/O ratio of approximately one suggests that all of what is with indoor air samples. In some jurisdictions, it has been
detected indoors is attributable to outdoor (ambient) air. suggested that outdoor air sampling should be started one
This is commonly observed for compounds such as chloro- hour prior to the start of indoor air sampling to account for
methane, carbon tetrachloride, and various chlorofluorocar- the time lag for any changes in outdoor air concentrations to
bons, which are commonly detected but are often found at reach steady-state conditions within the building. While this
the same concentration indoors as in outdoor air. is the technically correct approach, it is generally unneces-
sary in actual practice. For the vast majority of VOCs, the
outdoor air concentrations are too low to be significant. For
In our opinion, it is recommended that the outdoor air the few VOCs where outdoor air concentrations can be an
issue, the outdoor air values reflect regional or area back-
sample be the first sample started during a sampling event.
ground levels, and the concentrations will be reasonably
constant over the time frame of sampling.
To account for the contribution of outdoor air, it is common
practice to collect an outdoor air sample in conjunction If there is a localized outdoor source that has significant
with any indoor air samples. The outdoor air sample can be fluctuations in strength over very short time periods, a single
collected at the air intakes of the building if those exist and outdoor sample will likely not be sufficient to characterize the
are accessible. Alternatively, the outdoor air sample can be outdoor air quality (whether it is started at the same time as
collected a short distance upwind of the building at a location the indoor air samples or started one hour prior to them). The
that meets USEPA air monitor siting guidelines (e.g., a speci- changes in source strength combined with changes in meteo-
fied distance away from trees, walls, and other obstructions rology will result in increased spatial variability compared with
to free air flow) and minimizes the impacts from any localized a constant-strength source.
air emission sources such as roadways.
In the field, it typically takes at least a few minutes to sequen-
When and for how long should outdoor air samples be tially turn on each of the samplers due to the time for the
collected? Indoor air samples are point-in-time determi- sampling crew to move from one sampling location to another,
nations of air quality. Air concentrations inside residential record information, etc. It is recommended that the outdoor air
buildings may exhibit some short-term temporal variability sample be the first sample collected during a sampling event.
due to changes in the activities of occupants (e.g., cooking,
sleeping) and changes in building operation (e.g., HVAC
cycling on and off). These variations are assumed to average
out over a 24-hour diurnal cycle, so the standard practice
is to collect 24-hour time-integrated samples to address
residential exposures.1 For non-residential buildings,
the standard practice is to collect 8-hour time-integrated
1 Changes in local meteorology such as wind direction, wind speed, atmospheric stability, solar radiation, and precipitation will not average out over periods of 24 hours or
less; therefore, it is good practice to record readings for those variables during the sampling period and in the days immediately prior to the sampling period to aid in evaluating the
sampling results.
www.haleyaldrich.com PAGE 7 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
2 In typical use, soil vapor and soil gas are equivalent, interchangeable terms, though a distinction is sometimes made based on whether a given chemical may be either a
gas or a liquid at room temperature (soil vapor) or is only a gas (soil gas).
www.haleyaldrich.com PAGE 8 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
3 Mass transfer is often described using the two-film theory, where mass transfer from one phase to another involves transport from the bulk of one phase to the phase
boundary or interface, then movement from the interface into the bulk of the 2nd phase.
www.haleyaldrich.com PAGE 9 OF 15
τ (hr) =
𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵 𝑉𝑉𝑉𝑉𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑉𝑉𝑉𝑉𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝐵𝐵𝐵𝐵𝑉𝑉𝑉𝑉𝐵𝐵𝐵𝐵 𝑅𝑅𝑅𝑅𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉 (𝑉𝑉𝑉𝑉3/ℎ𝑟𝑟𝑟𝑟)
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
(Eq.
(Eq.2)3)
Topic #7 – Rebound time 2 𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵 𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝑉𝑉𝑉𝑉𝑒𝑒𝑒𝑒 (𝑉𝑉𝑉𝑉3)
τ (hr) =𝐿𝐿𝐿𝐿
The slow rate of partitioning discussed above also has impli- t= 𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵 𝑉𝑉𝑉𝑉𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑉𝑉𝑉𝑉𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝐵𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝐵𝐵𝐵𝐵𝑉𝑉𝑉𝑉𝐵𝐵𝐵𝐵 𝑅𝑅𝑅𝑅𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉 (𝑉𝑉𝑉𝑉3/ℎ𝑟𝑟𝑟𝑟)
cations for operation of SVE systems. The fact that the mass
Equation 3 𝐷𝐷𝐷𝐷𝐵𝐵𝐵𝐵
of VOCs in the vapor phase is a small fraction of the total
implies that the system must be operated for an extended
where:
period of time to be effective. Removing just one or two
t = time (in seconds [sec]);
soil air-filled pore space volumes will not result in complete (Eq.
L = distance (in3)
centimeters [cm]); and
mass removal. The fact that phase partitioning is a relatively
Di = Diffusivity in air (square centimeters per second [cm2/sec]).
slow process implies that continuous operation will tend to 𝐿𝐿𝐿𝐿2
remove mass from the pore spaces faster than it is replen- t =(Eq.
The transport distance is typically assumed to be several
4)
ished. This is evidenced by declining soil vapor concentra-
𝐷𝐷𝐷𝐷𝐵𝐵𝐵𝐵
times the straight-line distance due to the tortuosity of the
tions over time and lower rates of mass removal. Therefore, soil (i.e., the path that a VOC molecule takes through the
pulsed SVE operation may be a more cost-effective option interconnected t = Θair-filled
2 pore spaces is two to three times
a Rv L / Deff
than continuous operation. After the SVE system is tempo- longer than the straight-line distance).
rarily shut down, there can be an increase or “rebound” in
soil vapor concentration back to near the original, starting An alternative approach is that of Johnson, et al. (1999). This
concentration. method calculates the time required to achieve steady-state
soil vapor concentrations for a specific constituent and takes
When SVE has reached the point of diminishing returns, the (Eq.
into account 4)type.
soil
system may be shut down permanently. A typical requirement
is to wait an appropriate amount of time, then test soil vapor to
assess whether the soil vapor concentrations are at acceptable Equation 4 t = Θa Rv L2 / Deff
levels after any potential rebound has occurred. The question
is: How long do you need to wait after SVE system shutdown where:
before testing for rebound in soil vapor concentrations? θa = air-filled porosity (unitless);
Rv = vapor-phase retardation factor; and
The following discussion assumes that rebound is dominated Deff = effective diffusivity (cm2/sec).
by diffusive transport. The time estimates will be conservative
The air-filled porosity will vary with soil type as will the effective
if advective or other transport mechanisms are the dominant
diffusivity, which is calculated based on the Millington-Quirk
mode of transport, such as might be the case at fractured
relationship. The retardation factor will be 1 for alkanes but
bedrock sites or sites with other preferential pathways.
may be between 10 and 100 for monoaromatic hydrocarbons
The key is understanding and defining the transport distance because of their potential for aerobic biodegradation. Most
between the source of the vapors and the monitoring loca- chlorinated VOCs also should have a retardation factor of 1.
tion and depth. For example, if there is a groundwater or soil
Results are plotted in Figure 3 for the two estimation
source at 6 meters (m) and nested soil vapor probes at 1.5
approaches for TCE in a clay soil. The transport distance
and 3 m depths, the transport distance to the deeper probe
was assumed to be two times the straight-line distance for
is 3 m and the transport distance to the shallower probe is
the Jury method calculations. The vapor-phase retardation
4.5 m. So, we would expect to see new steady-state concen-
factor was assumed to be 1 for the Johnson, et al. method
trations sooner at the deeper probe than at the shallower
calculations. The two methods show reasonable agreement
probe. But recognize that if the source of vapors is intersti-
for this soil type.
tial pore water, the transport distance may be relatively short
and may be the same for both probes. The required wait times for rebound to occur are less than
one week for 1 m distances (6.7 days for Jury method and
Two predictive tools for estimating rebound time for various
3.8 days for the Johnson, et al. method) and less than one
distances are presented. The Jury method (Devitt, et al.,
month for 2 m distances (27 days for Jury method and 15.3
1987) is based on the diffusivity in air for a given compound
days for the Johnson, et al. method). The wait for rebound to
and distance:
www.haleyaldrich.com PAGE 10 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
occur exceeds three months by either method for distances of Also outside the scope of this paper is what time, if any, is
5 m, and the wait times exceed one year by either method for needed to account for changes in environmental variables such
distances of 10 m. There are significant advantages in time to as barometric pressure changes, temperature, rain events, etc.
reach a decision if the monitoring locations are located close There, the key issues are the magnitude of the effect and how
to the source of vapors. far it extends down into the soil column. For more information,
see Eklund (2016).
Jourabchi and Lin (2021) recently refined the Johnson, et al.
approach and demonstrated that the time to reach steady-
Topic #8 – Chemical Kinetics
state conditions is dependent on the distance of the entire
pathway, not just the distance between the vapor source and Chemical kinetics addresses the rate of chemical reactions. In
the monitoring location. This difference is relatively insignif- VI studies, most VOCs are assumed to be inert and to persist
icant when the distance between the vapor source and the unchanged in the subsurface over the time frames of interest.
monitoring location is only 1 or 2 m. However, biodegradation and chemical reactivity are common
exceptions that practitioners should keep in mind. These are
discussed below.
The relatively long wait times associated with longer distances How long do you need to wait for biodegradation processes
shown in the above Figure also have implications for how to reach steady-state conditions? For biofilters, a three- to
long it takes for sites with new releases to reach steady-state six-week conditioning period is needed to allow the microor-
conditions. That is a complicated topic and outside the scope ganisms to adapt to the gas-phase compounds being treated
of this paper, but it should be recognized that sites may be (Janni, et al., 2011). A similar time frame is assumed to apply
under transient conditions for some number of months after a to natural aerobic processes in the subsurface.
release occurs.
www.haleyaldrich.com PAGE 11 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
Some chlorinated VOCs such as tetrachloroethylene (PCE) Acrolein is sometimes detected in soil vapor samples, and it
and TCE will undergo anaerobic biodegradation in oxygen-lim- too can be a sampling artifact. Acrolein concentrations may
ited environments. That process tends to be relatively slow, increase over time in TO-15 canisters that contain relatively
and soil gas concentrations generally are expected to be high concentrations of polar compounds (e.g., alcohols,
stable over time frames of months. ketones). Low humidity in the samples and heating of the
canisters during the cleaning process are contributing factors
Highly reactive chemicals tend to have relatively low screening to rates of acrolein formation (Shelow, et al., 2009) (Swift, et
levels if they can react with lung or other bodily tissue and result al., 2006) (Whitaker, et al., 2015). If acrolein is detected in soil
in potential adverse health effects. However, this same reac- vapor, it may be formed endogenously in the canisters and can
tivity leads these chemicals to have relatively short half-lives, therefore be a sampling artifact; its steady-state concentra-
which limits their transport in the subsurface. Two examples tion in soil vapor is essentially zero.
of reactive chemicals that sometimes are an issue in VI studies
are acrolein and 1,3-butadiene. These chemicals are produced
during combustion processes and both are unsaturated (i.e., Summary
have carbon-carbon double bonds). The double bonds contribute
A conceptual site model (CSM) summarizes key information
to their reactivity.
about a site so that stakeholders have a common under-
standing of what is known about the VI pathway for a given
H
O C H site. A robust CSM is especially needed in VI studies to guide
H C C H the design of any testing to be performed. As new informa-
Acrolein tion becomes available, it is compared with the CSM and the
CSM is adjusted as appropriate. When developing a CSM for
vapor intrusion, the importance of steady-state conditions is
H H often overlooked. The consideration of steady-state condi-
C C tions and incorporation of this information into the CSM is
H
C C
H
important for designing defensible, efficient VI studies. The
H H key points addressed in this paper are summarized in Table 1.
1,3-butadiene
www.haleyaldrich.com PAGE 12 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
Removal of a VOC source from inside Wait a minimum of 4 residence times Indoor surfaces may continue to emit
a building to sample SVOCs for several days or weeks
Changes in building ventilation Wait a minimum of 4 residence times
to sample
Turning off building HVAC Wait up to 4 days to sample an office This type of testing is not practical or
building; wait up to 2 days to sample easily implemented and other options
other building types should be considered
Timing of outdoor air samples Collect concurrently with indoor air
samples
Timing of soil vapor samples Indoor air and soil vapor samples It also is not necessary that indoor air
collected within a few days of one and sub-slab soil samples have the
another should be considered concurrent same sampling duration
Partitioning in the subsurface Soil vapor can be collected as a
grab sample
www.haleyaldrich.com PAGE 13 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
References
ASTM D7663-12 (2018). Standard Practice for Active Soil Gas Sampling in the Vadose Zone for Vapor Intrusion Evaluations.
Revised 2018.
Devitt, D.A., R.B. Evans, W.A. Jury, T.H. Starks, B. Eklund, and A. Gholson. 1987. Soil Gas Sensing for Detection and Mapping
of Volatile Organics. EPA/600/8-87/036 (NTIS PB87-228516).
Eklund, B., L. Beckley, and R. Rago. Autumn 2018. Overview of State Approaches to Vapor Intrusion: 2018. Remediation, Vol.
28, Issue 4, pp 23-35.
Eklund, B. Effect of Environmental Variables on Vapor Transport. 2016. In: Proceedings of AEHS 26th Annual International
Conference on Soil, Water, Energy, and Air. San Diego, California. March 21-24.
Eklund, B. Evaluation of Soil-Gas Sampling Rate. 2011. In: Proceedings of Indoor Air 2011, the 12th International Conference
on Indoor Air Quality and Climate. Sponsored by ISIAQ. Austin, TX. June 5-10.
Janni, K.A., R.K. Nicolai, S. Hoff, and R.M. Stenglein. November 2011. Biofilters for Odor and Air Pollution Mitigation in Animal
Agriculture. Air Quality Education in Animal Agriculture; Mitigation Strategies: Biofilters. US. Department of Agriculture and
the National Institute of Food and Agriculture.
Johnson, P.C., M.W. Kemblowski, and R.L. Johnson. 1999. Assessing the Significance of Subsurface Contaminant Vapor
Migration to Enclosed Spaces: Site-Specific Alternatives to Generic Estimates, Journal of Soil Contamination, Volume 8, No.
3, pp 389-421.
Johnson, P.C., C. Holton, Y. Guo, P. Dahlen, H. Luo, K. Gorder, E. Dettenmaier, and R. Hinchee. July 2016. Integrated Field-
Scale, Lab-Scale, and Modeling Studies for Improving Our Ability to Assess the Groundwater to Indoor Air Pathway at Chlori-
nated Solvent-Impacted Groundwater Sites. SERDP Project ER-1686.
Jourabchi, P. and G. K-C. Lin. 2021. Modeling Vapor Migration for Estimating the Time to Reach Steady-State Conditions.
Groundwater Monitoring & Remediation.
McAlary, T. and T. Creamer. 2006. The Effects of Purge Rate and Volume on Sub-slab Soil Gas Samples. In: Proceedings
of the Fifth International Conference on Remediation of Chlorinated and Recalcitrant Compounds, Sponsored by Battelle.
Monterey, CA. May 22-25.
Shelow, D., J. Rice, M. Jones, L. Camalier, and J. Swift. 2009. Acrolein Measurements. Presentation at 2009 National
Ambient Air Monitoring Conference, Nashville, TN.
Swanson, G., B. Schumacher, J. Zimmerman, B. Hartman, and J. Elliot. 2010. Seasonal Variation of Soil-Gas Concentrations
Near and Under a Slab Over a Year. In: Proceedings of the Seventh International Conference on Remediation of Chlorinated
and Recalcitrant Compounds, Sponsored by Battelle. Monterey, CA. May 24-27.
Swift, J.L., M. Howell, D. Tedder, and R. Merrill. October 2006. Collection and Analysis of Acrolein using Compendium Method
TO-15. Presented at the QA Region 6 Conference, Dallas, TX.
U.S. Environmental Protection Agency (USEPA). 2012. Fluctuation of Indoor Radon and VOC Concentrations Due to Seasonal
Variations. EPA/600/R-12/673.
U.S. Environmental Protection Agency (USEPA). July 2007. Final Project Report for the Development of an Active Soil Gas
Sampling Method. USEPA, ORD, NERL, Las Vegas, NV. EPA/600/R-07/076.
www.haleyaldrich.com PAGE 14 OF 15
► HALEY & ALDRICH VAPOR INTRUSION WHITE PAPER: Steady-state considerations in vapor intrusion study design
U.S. Environmental Protection Agency (USEPA), National Center for Environmental Assessment. July 2018. Update for
Chapter 19 of the Exposure Factors Handbook – Building Characteristics. EPA/600/R-18/121F.
U.S. Environmental Protection Agency (USEPA). November 2006. Comparison of Geoprobe PRT and AMS GVP Soil-Gas
Sampling Systems with Dedicated Vapor Probes in Sandy Soils at the Raymark Superfund Site. EPA/ORD/NRMRL.
EPA/600/R-06/111.
U.S. Environmental Protection Agency (USEPA), Office of Solid Waste and Emergency Response. (2015a, June). OSWER
technical guide for assessing and mitigating the vapor intrusion pathway from subsurface vapor sources to indoor air, OSWER
Publication 9200.2-154. Washington, DC.
U.S. Environmental Protection Agency (USEPA), Office of Underground Storage Tanks. (2015b, June). Technical guide for
addressing petroleum vapor intrusion at leaking underground storage tanks, EPA 510-R-15-001. Washington, DC.
Whitaker, D., K. Oliver, and T. Cousett. 2015. Improving the Analysis of Acrolein in Ambient Air. Presented at the National Air
Toxics Monitoring and Data Analysis Workshop. October 28.
www.haleyaldrich.com PAGE 15 OF 15
AUTHOR’S BIOGRAPHIES
This paper should be referenced as follows: