You are on page 1of 6
— Laliet isos OGGETIO NOTA TECNICA Ee eet re corse som MICROPROCESSOR somata seo —T Ale |Orloag a 8 421 LED number. O= 1p oF meaning : @- LD on OO0000 CO000®e o00e0 000 ee o00e@00 o0@je 00ee0 C00eee O0@000 oe00e Ooe@0@e0 080 ee o@e@o0o C0@e0e O0@ee0 o@ece @oo0oo0o e@000ce aL 12 13 14 15 16 7 @00e0 NOTE: LED indications 12 or 17 (contactors stuck) may also be caused by failure of diode in parallel with contactor coil or by failure in the electronic circuit on CSM/2 which controls the supply to the contactor coil (it does not cut the supply). Microprocessor or EPROM n° 1 badly inserted or damaged door closure timeout door opening timeout mon energizing of contactor A or B at the start (or TCP) mon making of A or B control contacts (or TCP) non energizing of contactor TAV at the star energized non making’ of the TAV control contact A or B starting of hoist gear timeout with car at floor level inductors FS or FD not closed with car not at floor leve: setting switch RSI (RS2) operated before the up-start setting switch RDI (RD2) operated before the down-start slow speed timeout non energizing of contactor TBV at speed change non making of TBV control contact timeout of inductors CS or CD plate count relay RCS not energized floor counter wrong resetting switch RS1 (RS2) not operating at the top floor resetting switch RD1 (RD2) not operating at the bottom floor contactor A or B or TAV or TBV stuck de-energizing of contactor A or B during the run opening during the run of car or landing door contacts error in data trasmission (only with Duplex, Tx, Qx) contact opening of photocell relay, hoist gear motor ther mal relay, safety edges, relay RCE normal working order contactor TAP or TCP stuck floor selector setting switch closed after the inductor epi (cb2) or csi (cs2) ‘ime ‘nnotanon BB/lon ‘ivieto_di_riproduzione_o divulgazione (Art. 2-99 legge 22-4-1947 N. 633) __Ne_2 sheets — sheet N° 1 ts = 20/12 OGCETTO NOTA TECNICA ge INSTALLATION WITH MICROPROCESSOR EQUIPMENT CSM] tap ayoreation pageg 2 TE —| AE QF LED INDICATION TABLE 210 tl oO ieto_di_riproduzione_o divulgazione (Art. 2-89 legge R2-4-1847 HN. B33) BR/ am = LED OFF LED number meaning : wea 422 @ = 1 ow e0ccee is = @0e00 20 = @e09@ece a @e0@eeo 2 = e0c5ecee 23 = @@000 24 = priority contact closed (PMP, EMG, LFT, EME, RRS) * @ee0oce 25 = : @e@e0e@eo 26 = ee0cee 27 = @@@00 — 2 = electric interference on board CSMI ee@0ece 29 = @@ GOO = 20 = EPROW n® 2 or n° 3 badly inserted or damaged COCO @ = 2 = LED check PMP = Firenen's operation | EMG = Emergency supply with standby generator * LPT = Car attendant operation EME = Exclusion of landing calls RRS = Floor levelling correction N* 2 sheets - sheet Ne 2 20/12/1983 o| z ale |sels tI PC BOARD _CSN/5 YELLOW LED + §B = Indicates 5 Volt supply voltage at terminal + 5B of PC board CSM/15, RED LED'S 1, 2, 4, 8, 16 = Indicate particular operating conditions or failures detected by the electronic equipment When the supply is switehed on there will be the following signal sequence : 1) ALL RED LED'S OFF (about one second) 2) ALL RED LED'S ON (about one second) 3) LED 16 ON: normal operating condition Each RED LED has a numeric value: the sum of values of lit led's gives the num ber of the latest operating condition detected by the equipment, as described in included table of signals. Example: LED 2 and 6 lit (2+ 8 = 10) 10 = relay [HBB not energized (tne control contact on relay "RCs" is not making) The last 10 failures are recorded in memory; to recall one by one the relevant LED signal it is necessary to switch off the automatic switch "AM" and operate push button "PG", The indication 10 (relay "RCS" not energized) will appear and, while "PG" is pushed, will be replaced by the indication of the latest failure detected. When "PG" is released it will again appear the number 10. While operating again "PG" it will appear the indication of the latest but one failure detec= ted. This can be repeated until all failures recorded have been shown. To cancel the failures recorded it is necessary to push "PG", for about 5 se conde, until LED 16 (normal working condition) comes on. NOTE = Indications 10, 15, 24 cannot be cancelled by means of "PG". If push button "PG" (line 100-103) is operated while main supply is being swit ched on indication 16 will flash. If LED give a flashing indication, the number shown indicate the latest failu= re detected, which 1s so unsafe that the microprocessor unit is keeping the NOTE = When there is a flashing LED indication it is not possible to read the previous indications recorded in memory. PC BOARD _CSM/8 RED LED'S KO; K1./.K73 J The above LED's, when lit, indicate that the relevant electronic cireuit on PC board CSM/2 is "ON" to operate the corrisponding contactor or relay. ; J1./.J7 = Operation of contactors or relays ‘ime ladon eto_di_riproduzione o divulgazione (An. 2-99 legge 22-4-1947 N. 633) s 20/12/1983 OGGETTO NOTA TECNICA ne CHECK WORKING ORDER OF PRINTED CIRCUIT BOARD CSM1 = CSM2 = CSM3_— CSMS AIEISH2 t esta ~ osus - Cut off the supply to the control panel, open the autonatic "TICINO" switch and put on the supply. LED + 5B must light up immediately showing that the power aupply gives voltage + 58; after 1/2 a second LEDS N. & and N. 2 (= N. 10) must light up showing that relay RCS is not energized. ~ Check the voltage across the following power supply terminals, on boards CSM/1 and CSM/3, and the earthing terminal (ov) CSM/1 Terminal Voltage CSM/3 Terminal + 5B + “BV + 0,25 + SB + ov ~ v - 84 0,25 ¥ =v +16 ev + av +18 aki, 42 wv + Vv swe ev + wv ev If some of these values do not correspond, check the fuses connected to terminals 12A, 5A, 5A, (use only 2,5 A rapid fuses). If fuses are not blown; replace board CSM3 if the supply transformer 4a working properly. ~ Check the voltage on the terminals of the printed eirouit board, with ‘the power supply on as per the attached table 1 (only for boards SM1/S); all voltage are referred to ground (OV terminals). 3 o If, with the wires connected to the terminals, the voltages are not = those shown in column 2, but with the wires disconnected the volt 5 ges are the sane ae those in column 3, the failure could be due to 3 devices outside the printed circuit board. < With ell the wires disconnected, except: the power supply, «Ki, 4/2 g and 8A4+8AS, the LED on the printed circuit board CSM5 must show N.10. & ¥ | z 3 3 5 | tim ‘snolanonn ° 3 sheets - sheet n° 1 Eee ee eee EL carne 20741271983 bs] AT‘O (30 qg1)Ag‘e 7 10 (uo aa1) as2*o At'o F agte 9 10 Zz wl Ld Ato * acty ato F uty atto F uty "DM a) nzto @ at'y azto Fay aso‘o F nsz‘o ° ASO‘O * Az‘O ASO*O * ASZ‘O ‘ASO‘O + AzZ‘O z n2'o Fatty 220 F av 40'0 ¥ asz*o ed nz ynoge AT 3noqe At‘o L pasora 2 498309 9u0 3889T 38 AET/S 3 arto F 90 = ted eqoequoo tre a3" - $ at‘o ¥ p9'o - g ps"et anoqe speseess ( AS*et/6 10 2 AG‘eT anoqs sus sy sjoequoo pas { as'et/6 10 3 AS'zt anoge =OT9 Jo sequnu eu gy ( AS‘2t/8 a0 8 n2t ynoge sasvosoap aBe3toa ayy ( azt/a 10 ede az F at 2 3 aot no 2es nz 7 nat a2 F net nz F net 35 TIT- Tr T 28) 38) gl *TT uuntos Slo} |] ur uacue 3eu3 03 ques “t+ 03 Touoyzu0doad sy gvT+LvT 3 Oo =9J5TP 2BezTOA @ pons ‘@aT+LaT ‘2uT ‘Zrt ‘oSe ‘ase STWUyWIe Qe eBeZTOA ayy fenTeA TeUTWOU 21] |] Bow suracy soz0 teusw 243 wos quazessyp 9q UBD 37 exOsoueyR ‘pezUTnBex you sy BT+ ATddns ouL Slo} |] Zea oua oss sazzm aug “ty Buyzoeuuco veqze puoces B 2/T ATequuyxoudde BB) |] 20 oar oyy yoouuoossa = “EN | TF uwntoo uy eBoy, 07 ‘T UWNTOD UT SaNTeA 943 Woy seBUBYD eBEaTOA auL y00u =Uoostp sauTm zeu30 eu3 * (Try Aiddns semod ayy UyTA 83BzTOA SOUTR TI® UTM BVI TOA Tay TeuyuIe3 4B eaTA UZTA eBEq TOA ave-vve sve-zve ges-za8 exs-2ra Tye-Tre Ove /ew gav/cav euy-2ey ose Oviecyt gattsat oat-Lat ut act ose ase “WNINEaL F mY 3 sheets - sheet n® nnotanone i (€E9 N LOBL-Y-2z 84 GES W) eowedjeap o auoRPOGU |p o| © © fe 2 40/12/1903 OGGETIO NOTA TECNICA | ie CHECK WORKING ORDER OF PRINTED CIRCUIT BOARD sca a alelsd> al osm 1) If only one output from the printed circuit board is not correct (one contactor or relay doesn't energize or remains energized, or a light indicator doesn't light or remains always lit) look for a breakdown in the printed circuit board CSM2. 2) If the coils and light indicators are connected to the plus power supply, connecting the earth to the correct output terminals on printed circuit board, they are energized. Tt is possible ‘to check if there is a breakdown in the external cir cuit. 7 | 3) Removing the wires from the terminals and connecting a light indi { cator of suitable voltage’across the plus and same terminal, it is | possible to check if the output is correct. | 10-4 in an output witch, a relay or «contactor, Kxep ia ainsimer | during the above test the installation cannot work correctly. | 4) Before replacing the CSM2 board in any case, remove tte connections with CSM1 and check that this works correctly, checking the volta= i ge to the terminals connected with the CSM2 (45C, 4J2, 4K2, 437 + ABP, 4074448). sus - 3 = To check, printed circuit board CSNS connect its terminal +5 to the 8 supply voltage SV (1f t isn't already connected) and the others to earth (terminal OV) after having disconnected them from CSMi. | = In this way the LEDs must Light. i * | s g 3 ¥ 2 3 a = 2 | 4 | £ \ 3 8 |i codon Wat S sheets = sheet ae 3 | ere

You might also like