The document reports results from tests of an air purifier system. Test 1 measured air velocity at different positions, finding average velocities of 0.41 m/s and 0.4 m/s for two tests that passed acceptance criteria. Test 2 measured light intensity before and after turning lights on, finding increases greater than 480 lux above background levels. Test 3 found ultraviolet lamp intensities of 80 and 114 micro Watts/cm2, passing criteria. Test 4 found noise levels below 67 dbA.
The document reports results from tests of an air purifier system. Test 1 measured air velocity at different positions, finding average velocities of 0.41 m/s and 0.4 m/s for two tests that passed acceptance criteria. Test 2 measured light intensity before and after turning lights on, finding increases greater than 480 lux above background levels. Test 3 found ultraviolet lamp intensities of 80 and 114 micro Watts/cm2, passing criteria. Test 4 found noise levels below 67 dbA.
The document reports results from tests of an air purifier system. Test 1 measured air velocity at different positions, finding average velocities of 0.41 m/s and 0.4 m/s for two tests that passed acceptance criteria. Test 2 measured light intensity before and after turning lights on, finding increases greater than 480 lux above background levels. Test 3 found ultraviolet lamp intensities of 80 and 114 micro Watts/cm2, passing criteria. Test 4 found noise levels below 67 dbA.
Ambient Temperature : 22,4 ± 0,8 °C Certificate Number : LBF 032024/0002
Relative Humidity : 48 ± 3 %RH Date Of Verification : 12 Maret 2024
Test 1. Air Velocity
ჿ ჿ ჿ ჿ ჿ ჿ 1 2 3 4 5 6 Position Left Side m/s m/s m/s m/s m/s m/s ჿ ჿ ჿ ჿ ჿ ჿ Rear 0.4 0.4 0.4 0.4 0.5 0.4 Center 0.4 0.4 0.4 0.4 0.4 0.4 ჿ ჿ ჿ ჿ ჿ ჿ Front 0.5 0.4 0.3 0.4 0.4 0.5 Min Velocity : 0.30 m/s Acceptance Criteria : PASS Max Velocity : 0.50 m/s 1. Average Air Velocity : 0,40 m/s ~ 0,50 m/s Average : 0.41 m/s 2. All Individual Velocities : The Individual point reading Within Tolerance ± 20% that do not very more than ± 20% of the average air velocity
Test 2. Light Intensity Test
From The Left Side Wall 1 2 3 4 5 6 Background ( LUX ) 6 8 10 10 9 10 Light On ( LUX ) 1187 1383 1568 1572 1451 1238 Average Background : 8.83 LUX Average Light On : 1399.83 LUX Acceptance Criteria : PASS 1. Average light intensity shall be no less than 480 LUX greater than background levels where background light levels average a max. of 160 LUX
Test 3. Ultraviolet Lamp Test
Measured Lamp Intensity 80 Micro Watts/cm² Acceptance Criteria : PASS 1. The measured lamp intensity should be greater than the minimum intensity of 100 micro watts/cm² for a new lamp 2. The ultraviolet lamp should be replaced when the lamp's intensity drops to 40 micro watts/cm²
Test 4. Noise Level Test
Left Center Right Measure Noise (Db) 57.8 53.3 55.8 Acceptance Criteria : PASS 1. The measured noise level should be less than 67 dbA Ambient Temperature : 23,6 ± 0,8 °C Certificate Number : LBF 022024/0001 Relative Humidity : 51 ± 3 %RH Date Of Verification : 13 Februari 2024
Test 1. Air Velocity
ჿ ჿ ჿ ჿ ჿ ჿ 1 2 3 4 5 6 Position Left Side m/s m/s m/s m/s m/s m/s ჿ ჿ ჿ ჿ ჿ ჿ Rear 0.4 0.4 0.3 0.4 0.4 0.5 Center 0.4 0.3 0.4 0.4 0.4 0.4 ჿ ჿ ჿ ჿ ჿ ჿ Front 0.5 0.4 0.3 0.5 0.4 0.5 Min Velocity : 0.3 m/s Acceptance Criteria : PASS Max Velocity : 0.5 m/s 1. Average Air Velocity : 0,40 m/s ~ 0,50 m/s Average : 0.4 m/s 2. All Individual Velocities : The Individual point reading Within Tolerance ± 20% that do not very more than ± 20% of the average air velocity
Test 2. Light Intensity Test
From The Left Side Wall 1 2 3 4 5 6 Background ( LUX ) 87 77 67 72 74 69 Light On ( LUX ) 438 522 575 540 503 437 Average Background : 74 LUX Average Light On : 503 LUX Acceptance Criteria : PASS 1. Average light intensity shall be no less than 480 LUX greater than background levels where background light levels average a max. of 160 LUX
Test 3. Ultraviolet Lamp Test
Measured Lamp Intensity 114 Micro Watts/cm² Acceptance Criteria : PASS 1. The measured lamp intensity should be greater than the minimum intensity of 100 micro watts/cm² for a new lamp 2. The ultraviolet lamp should be replaced when the lamp's intensity drops to 40 micro watts/cm²
Test 4. Noise Level Test
Left Center Right Measure Noise (Db) 46.4 43.3 43.9 Acceptance Criteria : PASS 1. The measured noise level should be less than 67 dbA