Professional Documents
Culture Documents
Prelime Design
Prelime Design
Sun Set
• Produces glare effect
• Trees should be Slope
planted to reduce
effect
South East Mansoon Wind Sun Rise
It results in rainfall Sunrises around 6:30am which produce
Proper drainage should lighting effect
be made Existing stream Shading devices should be provided
Water to be channeled to Should be retained Should be utilized as source of light
farmlands Water should be channeled
Reg P17EVAT8037 and treated for domestic use Scale
Code ARCH 801 PROPOSED STAFF HOUSING Mentor Dr. H. Babangida
Date 22-02-2018 Date 22-02-2018
SITE ANALYSIS
Slope
N
The site has gently slope towards the south
Slope gradient of about 0.7%
Drainage should be channeled to follow
Slope North East Trade Wind
• Tress should be planted • Comes along with dust
Site Soil to reduce wearing and sand and cause
characterized by sandy silty soil and harmattan
lateretic gravely sand • Proper orientation
The soil is poor for Agri. Production and should be made
susceptible to erosion • Tree planting should be
Ground cover plants should be introduced encouraged
N N S S S S S S S S N N Wind 800
W E E W W W W W W W W E E 600
400
200
D 0
J F M A M J J A S O N D
Wind Relative humidity
• The site experiences high temperature
around March to June chart
• Planting of trees should be encouraged
• Proper building materials should be
selected
Rainfall
chart
Farm land
• MOST PRIVATE
MOST ZONE • MORE PRIVATE
PRICATE ZONE
ZONE
Most private due to
nearness to
farmland on both
sides
Should be allocated
to principal and
academic staff.
NIGERIA
ZAMFARA
AFRICA
THE SITE
Reg P17EVAT8037 Scale
Code ARCH 801 PROPOSED STAFF HOUSING Mentor Dr. H. Babangida
Date 22-02-2018 Date 22-02-2018
DESIGN CONSIDERATIONS
A 21m back to back separation distance should be
provided between windows to habitable rooms for
• Back to Back two floor dwelling in order to provide adequate
relationship privacy within the home
• Limited wind
exposure
• Maximized wind
exposure
SINGLE BEDROOM Bed 2000 x 900mm, bedside tables 400 x 400mm, chest Small: (3600mm x 4200mm) Medium: (4200mm x 6000mm)
of drawers 750—950 x 450—600mm, Large: (4800mm x 7200mm)
wardrobe/cupboard.
DINING AREA Dining table and occupiers chairs Small: (3000mm x 3600mm) Medium: (3600mm x 4200mm)
Large: (4200mm x 4800mm)
KITCHEN cupboard, drawers, tray space, wall unit, work tops, Small:(1500mm x 3000mm) Medium: (2500mm x 3900mm)
cooker, refrigerator, sink tops and drainers. Large: (3000mm x 3600mm)
BATHROOM WC, cistern, bath and wash hand basin. Small: (1500mm x 2700mm) Medium: (1800mm x 3000mm)
Large: (2100mm x 3600mm)
INTERNAL Enclosed storage, ironing board, sewing machine, food Small: (1800mm x 1800mm) Medium: (2500mm x 3000mm)
STORAGE storage, gardening equipment, e.t.c. Large: (3000mm x 3000mm)
MASTER Master bathroom is generally attached with master Small: (1800mm x 2700mm) Medium: (2100mm x 3000mm)
BATHROOM bedroom Large: (2500mm x 3600mm)
CHILD BED ROOM Child bed room is made for children. This room is Small:(3000mm x 3600mm) Medium: (3600mm x 4200mm)
like any other bed room. Large:(4200mm x 4800mm
GUEST BED ROOM Guest bed room is as normal bed room and it is Small: (3000mm x 3600mm) Medium: (3600mm x 4200mm)
made for guest. It can also be called common bed Large: (4200mm x 4800mm)
room.
OFFICE ROOM You can use the guest room as an office room. Small: (2500mm x 3000mm) Medium: (3000mm x 3600mm)
Because, guest room isn’t always used. But some Large: (3600mm x 4200mm)
prefer to have a separate office room in an
apartment.
FOYER Foyer is a lobby or corridor used in an apartment of Small: wide (1500mm) Medium: wide (1800mm)
a residential building to separate the entrance from Large: wide (2500mm)
living room. But some prefer to omit the foyer and
use the living room as an entrance of the apartment.
DRESSING ROOM Dressing room is provided in front of Master Small: (1200mm x 1200mm) Medium: (1500mm x 1500mm)
bathroom. It doesn’t need to provide dressing Large: (1800mm x 1800mm)
room with any other bathroom.
A= Storage surface
B= cooker
C= storage surface
D= Sink
E= Draining surface
F= Cupboard unit
G= Wall unit
H= Full height cu[board
Two sided Kitchen
Reg P17EVAT8037 Scale
Code ARCH 801 PROPOSED STAFF HOUSING Mentor Dr. H. Babangida
Date 22-02-2018 Date 22-02-2018
SPACE ANALYSIS
Dining • for round table =
𝑠𝑒𝑎𝑡 𝑤𝑖𝑑𝑡ℎ 𝑚 𝑋 𝑁𝑂.𝑝𝑒𝑜𝑝𝑙𝑒
3.142
no. of diners Width Depth Space
(m) (m) required
(𝑚2) 600𝑚𝑚 𝑋 6 𝑝𝑒𝑜𝑝𝑙𝑒
for 600mm seat width and six [people= =1.15𝑚2
3.142
4 people >1.3 2.6
5 people >1.8 3.8
6 people >1.8 >1.95 3.9
Sustainable architecture
Sustainable architecture can be simply defined as doing the most with
the least means
Sustainable design
Sustainable design articulates this idea through developments that
exemplify the principles of conservation and encourage the application
of those principles in our daily lives.
Housing
Housing refers to planning or provision of accommodation by an
authority.
Sustainable housing
This refers to houses that are designed to reduce the overall
environmental impact during and after construction in such a way that
we can meet the need of the present without compromising the ability of
future generations to meet their own needs.
Staff
Staff refers to all the workers employed in an organization considered as
a group
Reg P17EVAT8037 Scale
Code ARCH 801 PROPOSED STAFF HOUSING Mentor Dr. H. Babangida
Date 22-02-2018 Date 22-02-2018
INTRODUCTION
COMPONENTS OF SUSTAINABILITY
Security
Reg P17EVAT8037 Scale
Code ARCH 801 PROPOSED STAFF HOUSING Mentor Dr. H. Babangida
Date 22-02-2018 Date 22-02-2018
CONCEPT 2
Total =
Reg P17EVAT8037 Scale
Code ARCH 801 PROPOSED STAFF HOUSING Mentor Dr. H. Babangida
Date 22-02-2018 Date 22-02-2018
BUBBLE DIAGRAM
PRINCIPAL STAFF
Master’s
convenien
SENIOR LECTURER Balcony ce
Stairs Master’s
bedroom
Central space
children
room Study
Female room
room
Female
convenience
First floor
Store
Dining
Males kitchen
room
conven Living room Stairs
ience
Ground floor guest Entran
room ce
Ground floor
Reg
Reg P17EVAT8037
P17EVAT8037 Scale
Scale
Code
Code ARCH 801
ARCH 801 PROPOSED STAFF HOUSING Mentor
Mentor Dr. H.
Dr. H. Babangida
Babangida
Date
Date 22-02-2018
22-02-2018 Date
Date 22-02-2018
22-02-2018
BUBBLE DIAGRAM
NON - ACADEMIC
JUNIOR LECTURER
Master’s Masters
Female bedroom
Master’s bedroom
room convenien Bathroom
ce
conveni
ence Toilet
Males Living room Living room
kitchen
room Children Dining
room
Entran Store
ce Store
Dining Entrance Kitchen