01-16 is not connected air filter 01-17 clogged air filter 02-16 Filter hydraulic / hydrostatic system is not connected 02-17 Filter hydraulic / hydrostatic system is connected 03-09 Low battery voltage 03-10 High Voltage Battery g 03-11 Extremely high voltage battery 03-14 Extremely low battery voltage 03-22 Battery voltage is below the limit 04-09 Low levels of engine oil pressure 04-14 Extremely low levels of engine oil pressure 04-15 Engine oil pressure at the level of the emergency engine shutdown 04-21 Engine oil pressure above the maximum permissible 04-22 Engine oil pressure below the limit 05-09 Low supply pressure in the hydraulic system 05-10 High charge pressure in the hydraulic system 05-11 Extremely high charge pressure in the hydraulic system 05-14 Extremely low supply pressure in the hydraulic system 05-15 charge pressure in the hydraulic system at the level of the emergency engine shutdown 05-21 charge pressure in the hydraulic system above the maximum permissible 05-22 charge pressure in the hydraulic system below the limit 06-10 high engine speeds 06-11 Extremely high engine speed 06-13 No engine speed signal 06-15 Engine speed at the level of the emergency engine shutdown 06-18 Engine speed is out of range 07-10 Heat the oil in the hydraulic system 07-11 Extremely high temperature hydraulic oil 07-15 The oil temperature in the hydraulic system at the level of the emergency engine shutdown 07-21 The oil temperature in the hydraulic system above the maximum allowable 07-22 The oil temperature in the hydraulic system below the limit 08-10 High engine coolant temperature 08-11 Extremely high engine coolant temperature 08-15 Engine coolant temperature at the level of the emergency engine shutdown 08-21 Engine coolant temperature is higher than the maximum permissible 08-22 Engine coolant temperature is below the limit 09-09 Low fuel level 09-21 Fuel level above the maximum permissible 09-22 Fuel level below the limit 10-17 clogged hydraulic filter discharge 11-05 frame sensor security shorted to battery 11-06 frame sensor security shorted to ground 12-21 Signal ShIMkontrollera front ext. hydraulics for the upper limit of the range 12-22 ShIMkontroller front ext. hydraulics for the lower range 12-23 ShIMkontroller front ext. Hydraulic not in the neutral range 13-05 Retaining fuel cutoff solenoid shorted to battery 13-06 Retaining fuel cutoff solenoid shorted to ground 13.7 Open circuit solenoid fuel cutoff Ing. Balzarini www.ingarconsultores.com maximiliano.balzarini@ingarconsultores.com+54 9 11 5656 8006 Página 1 Códigos Error www.ingarconsultores.com 14-02 retracting solenoid fuel cutoff, the erroneous inclusion 14-03 retracting solenoid fuel cutoff, erroneous shutdown 15-02 retracting solenoid lock rods, erroneous inclusion 15-03 retracting solenoid lock rods, erroneous shutdown 16-05 Retaining solenoid lock rods shorted to battery 16-06 Retaining solenoid locking rod is closed to ground 07-16 Break the chain holding the solenoid lock rod 17-05 hydraulic solenoid shut-off valve is closed to battery 17-06 hydraulic solenoid shut-off valve is closed to ground 17-07 Open circuit hydraulic solenoid shut-off valve 18.05 The solenoid slide is closed to battery 18.6 Solenoid spool is closed to ground 18-07 Open circuit solenoid spool 19-02 solenoid positioning bucket erroneous inclusion 19.3 Solenoid bucket positioning, incorrect shutdown 20-02 Solenoid switching speeds erroneous inclusion 20-03 Solenoid switching speeds, erroneous shutdown Glow plugs 21-02, the erroneous inclusion 21-03 Glow plugs, faulty shutdown Starter 22-02, the erroneous inclusion Starter 22-03, erroneous shutdown 23-02 Rear base solenoid erroneous inclusion 23-03 Rear base solenoid erroneous shutdown 24-02 Rear spindle solenoid erroneous inclusion 24-03 Rear spindle solenoid erroneous shutdown 25-02 Rear auxiliary proportional solenoid erroneous inclusion 25-03 Rear auxiliary proportional solenoid, faulty shutdown 2.26 The erroneous inclusion of the front base solenoid 3.26 Erroneous off the front of the base of the solenoid 27-02 erroneous inclusion of the stem of the front solenoid 3.27 Erroneous front off the stem of the solenoid 28.2 Solenoid relief valve, faulty switch 28.3 Solenoid relief valve, faulty shutdown 29.2 Solenoid large supply, faulty switch 29.3 Solenoid large supply, faulty shutdown 30-28 Failure memory controller 31-28 Fault recovery mode (also appears after the software update) 32-04 Advanced Management (ACS) does not communicate with the controller Bobcat 32-23 Calibration required ACS 32-24 Calibrate ACS 32-31 Fault actuator tilt ACS Faulty wiring 32-32 tilt actuator ACS 32-33 tilt handle the wiring ACS 32-34 ACS tilt actuator is not in the neutral position 32-35 The handle / pedal tilt bucket ACS is not in the neutral position 32-36 Fault actuator lift ACS Faulty wiring 32-37 actuator lift ACS 32-38 the wiring arm lifting ACS 32-39 actuator lifting ACS not in the neutral position 32-40 The handle / lift pedal bucket ACS is not in the neutral position 32-41 ACS: no connection 32-49 actuator lift ASS closed to ground Ing. Balzarini www.ingarconsultores.com maximiliano.balzarini@ingarconsultores.com+54 9 11 5656 8006 Página 2 Códigos Error www.ingarconsultores.com 32-50 tilt actuator ASS shorted to ground 32-51 actuator lift ASS shorted to battery 32-52 tilt actuator ASS shorted to battery 32-53 Handle / foot boom is closed to ground, ASS 32-54 Handle / foot slope of the boom is closed to ground, ASS 32-55 Handle / foot boom is closed to battery, ACS 32-56 Handle / foot slope of the boom is closed to battery, ACS 32-57 Reduced performance actuator lift ACS 32-58 Reduced performance actuator tilt ACS 32-59 Wrong direction of the actuator lift ACS 32-60 Wrong direction of the actuator lift ACS 32-61 Chain lock handle ACS shorted to ground 32-62 Chain lock handle ACS closed on battery 32-63 Chain lock pedals ACS is closed to ground 32-64 Chain lock pedals ACS closed on battery 32-65 Voltage sensor out of range ACS 32-66 Battery voltage ACS below the limit 32-67 Switch ACS switched during operation 32-68 Error Information Handle boom, ACS 32-70 Chain right arm movements ACS shorted to ground 32-71 Chain right arm movements ACS closed on battery 32-74 X-axis joystick left ACS is out of range 32-75 Power Off unswitched equipment ACS 32-76 Error Information joystick CAN, ACS 32-77 Error Information remote control, ACS 33-23 The main controller (controller Bobcat) is not programmed 34-04 panel with push-button starting the controller does not communicate with Bobcat 35-02 erroneous inclusion of the fan hydraulics 35-03 Mistaken off the fan hydraulics 36-48 connect multiple controllers ACD 37-02 Two-speed auxiliary switch speeds erroneous inclusion 37-03 Two-speed auxiliary switch speeds erroneous inclusion 38-01 Error Information joystick CAN 38-02 Error Information Remote Control 38-04 There is no communication with the controller joystick 38-05 X axis the left stick is not in the neutral position 38-06 X axis right stick is not in the neutral position 38-07 Y-axis of the left joystick is not in neutral 38-08 Y-axis right stick is not in the neutral position 38-09 mode switch control circuit to the battery or to ground 38-10 Calibrate actuator 38-11 lift actuator is not in the neutral position 38-12 tilt actuator is not in the neutral position 38-13 Failure of the actuator lift 38-14 Failure of the actuator tilt 38-15 Wiring Fault speed control right wheel 38-16 Wiring fault for the speed of the left wheel 38-17 Reduced performance actuator tilt 38-18 Reduced performance actuator lift 38-19 X-axis joystick for left upper range 38-20 X-axis right joystick for the upper limit of the range 38-21 Y-axis joystick for left upper range Ing. Balzarini www.ingarconsultores.com maximiliano.balzarini@ingarconsultores.com+54 9 11 5656 8006 Página 3 Códigos Error www.ingarconsultores.com 38-22 Y-axis right joystick for the upper limit of the range 38-23 front right sensor signal controls the upper limit of the range 38-24 front left sensor signal controls the upper limit of the range 38-25 rear right sensor signal controls the upper limit of the range 38-26 rear left sensor signal controls the upper limit of the range 38-27 Signal actuator for lifting the upper range 38-28 Signal actuator for tilting the upper range 38-29 X-axis joystick left for lower range 38-30 X-axis right joystick for the lower range 38-31 Y-axis joystick left for lower range 38-32 Y-axis right joystick for the lower range 38-33 front right sensor signal controls the lower end of the range 38-34 front left sensor signal controls the lower end of the range 38-35 rear right sensor signal controls the lower end of the range 38-36 rear left sensor signal controls the lower end of the range 38-37 Power "1" 5-volt sensor for the lower range 38-38 Power "2" 5-volt sensor for the lower range 38-39 actuator lift is closed to ground / lower boundary of the range 38-40 tilt actuator is closed to ground / signal for the lower range 38-41 Wrong direction of the tilt actuator 38-42 Wrong direction of the actuator lift 38-43 left front solenoid actuator erroneous inclusion 38-44 Solenoid left reverse drive, faulty switch 38-45 right front solenoid actuator erroneous inclusion 38-46 Solenoid right reverse drive, faulty switch 38-47 Front right solenoid control switch faulty 38-48 Front left solenoid control switch faulty 38-49 Rear right solenoid control switch faulty 38-50 Rear left solenoid control off erroneous 38-51 solenoid pressure control system, the erroneous inclusion 38-52 Back-up alarm, the erroneous inclusion 38-53 Solenoid left front drive off false 38-54 Solenoid left reverse drive, faulty shutdown 38-55 right front solenoid drive off false 38-56 Solenoid right reverse drive, faulty shutdown 38-57 Front right solenoid control extension, erroneous shutdown 38-58 Front right solenoid control retraction, erroneous shutdown 38-59 Front left solenoid control extension, erroneous shutdown 38-60 Front left solenoid control retraction, erroneous shutdown 38-61 Rear right solenoid control extension, erroneous shutdown 38-62 Rear right solenoid control retraction, erroneous shutdown 38-63 Rear left solenoid control extension, erroneous shutdown 38-64 Rear left solenoid control retraction, erroneous shutdown 38-65 solenoid pressure control system, faulty shutdown 38-66 Back-up alarm, erroneous shutdown 38-67 No communication from Bobcat controller 38-68 wheel alignment (alignment) not calibrated 38-69 Fault calibration actuators lift and tilt 38-70 Fault recovery mode range 38-71 Battery voltage out of limits 38-72 Pump drive is not calibrated 38-73 Control Mode Switch switched during operation Ing. Balzarini www.ingarconsultores.com maximiliano.balzarini@ingarconsultores.com+54 9 11 5656 8006 Página 4 Códigos Error www.ingarconsultores.com 38-74 Uncontrolled rotation speed of the right wheel 38-75 Uncontrolled rotation speed of the left wheel 38-76 solenoid pressure control system Undercurrent 38-77 Front right solenoid control extension Undercurrent 38-78 Front right solenoid control retraction Undercurrent 38-79 Front left solenoid control extension Undercurrent 38-80 Front left solenoid control retraction Undercurrent 38-81 Rear right solenoid control extension Undercurrent 38-82 Rear right solenoid control retraction Undercurrent 38-83 Rear left solenoid control extension Undercurrent 38-84 Rear left solenoid control retraction Undercurrent 38-85 Power "1" 5-volt sensor for the upper limit of the range 38-86 ° Power "2" 5-volt sensor for the upper limit of the range 38-87 Problem front right steering device for the lower range 38-88 Malfunction of the front left of the steering gear 38-89 Fault rear right of the steering gear Error 38-90 rear left control 38-91 No speed sensor impulses of the right wheel 38-92 No speed sensor impulses left wheel 38-93 right wheel speed sensor does not respond 38-94 left wheel speed sensor does not respond 38-95 Change of direction in the left wheel speed sensor 38-96 Change of direction in the right wheel speed sensor 38-98 controller in calibration mode drive 38-99 controller in calibration mode wheel position 39-04 Left joystick has no communication with the controller Bobcat 39-05 X-axis is not in the neutral position 39-07 Y-axis is not in the neutral position 39-12 manipulator switch left stick is not in neutral 39-13 is not connected joystick handle left off 39-16 is not connected joystick left off 39-28 Internal fault of the left joystick 39-48 Left joystick, multi-mode 40-04 Right joystick has no communication with the controller Bobcat 40-05 X axis right stick is not in the neutral position 40-07 Y-axis right stick is not in the neutral position 40-12 manipulator switch right joystick is not in neutral 40-13 is not connected right stick handle 40-16 is not connected right stick 40-28 Internal fault of the right joystick 40-48 Right stick, multi-mode 41-09 Low voltage generator 41-10 High Voltage Generator 41-11 Extremely high voltage generator 44-02 Horn, the erroneous inclusion 44-03 Horn, erroneous shutdown 45-02 The right turn signal, the erroneous inclusion 45-03 The right turn signal, erroneous shutdown 46-02 left turn signal, the erroneous inclusion 46-03 left turn signal, erroneous shutdown 47-21 Power 8voltovogo sensor for upper range
Ing. Balzarini www.ingarconsultores.com maximiliano.balzarini@ingarconsultores.com+54 9 11 5656 8006 Página 5
Códigos Error www.ingarconsultores.com 47-22 Power 8voltovogo sensor for lower range 48-02 front light switch, faulty switch 48-03 front light switch, faulty shutdown 49-02 Relay rear light erroneous inclusion 49-03 Relay rear light, faulty shutdown 60-21 signal lever back ext. hydraulics for the upper limit of the range 60-22 signal lever back ext. hydraulics for the lower range 60-23 lever rear ext. Hydraulic not in the neutral position 64-02 erroneous inclusion of a power relay 64-03 Mistaken off power relay 73-04 Fault remote control 73-13 Remote control signal is missing 74-72 Fault boot code controller Bobcat 75-01 Error Information joystick CAN 75-04 There is no communication with the controller drive 75-05 X axis the left stick is not in the neutral position 75-07 Y-axis of the left joystick is not in neutral 75-08 Y-axis right stick is not in the neutral position 75-09 mode switch ISO / H circuit to battery or to ground 75-13 jammed angle sensor right front wheel 75-14 jammed angle sensor left front wheel 75-15 jammed angle sensor right rear wheel 75-16 jammed angle sensor left rear wheel 75-17 left inclined plate is not in the neutral position 75-18 right oblique plate is not in the neutral position 75-19 X-axis joystick for left upper range 75-21 Y-axis joystick for left upper range 75-22 Y-axis right joystick for the upper limit of the range 75-23 Signal angle sensor right front wheel of the upper limit of the range 75-24 Signal angle sensor left front wheel of the upper limit of the range 75-25 Signal angle sensor right rear wheel for the upper limit of the range 75-26 Signal angle sensor left rear wheel of the upper limit of the range 75-27 Offset left oblique plate 75-28 Offset right oblique plate 75-29 X-axis joystick left for lower range 75-31 Y-axis joystick left for lower range 75-32 Y-axis right joystick for the lower range 75-33 Signal angle sensor right front wheel of the lower boundary of the range 75-34 Signal angle sensor left front wheel of the lower boundary of the range 75-35 Signal angle sensor right rear wheel of the lower boundary of the range 75-36 Signal angle sensor left rear wheel of the lower boundary of the range 75-37 Power "1" 5-volt sensor for the lower range 75-38 Sensor supply 2 for the lower range 75-39 Sensor Signal Left inclined plate for the top end of the range 75-40 Sensor Signal Left inclined plate for bottom of the range 75-41 Sensor Signal Right inclined plate for the top end of the range 75-42 Sensor Signal Right inclined plate for bottom of the range 75-43 left front solenoid actuator erroneous inclusion 75-44 Solenoid left reverse drive, faulty switch 75-45 right front solenoid actuator erroneous inclusion 75-46 Solenoid right reverse drive, faulty switch 75-47 Front right solenoid control extension shorted to battery Ing. Balzarini www.ingarconsultores.com maximiliano.balzarini@ingarconsultores.com+54 9 11 5656 8006 Página 6 Códigos Error www.ingarconsultores.com 75-48 Front left solenoid control extension shorted to battery 75-49 Rear right solenoid control extension shorted to battery 75-50 Rear left solenoid control extension shorted to battery 75-51 solenoid pressure control system is closed to battery 75-52 Back-up alarm, the erroneous inclusion 75-53 Solenoid left front drive off false 75-54 Solenoid left reverse drive, faulty shutdown 75-55 right front solenoid drive off false 75-56 Solenoid right reverse drive, faulty shutdown 75-57 Front right solenoid control extension shorted to ground 75-58 Front right solenoid control retraction shorted to ground 75-59 Front left solenoid control extension shorted to ground 75-60 Front left solenoid control retraction shorted to ground 75-61 Rear right solenoid control extension shorted to ground 75-62 Rear right solenoid control retraction shorted to ground 75-63 Rear left solenoid control extension shorted to ground 75-64 Rear left solenoid control retraction shorted to ground 75-65 solenoid pressure control system is closed to ground 75-66 Back-up alarm, erroneous shutdown 75-67 No communication from Bobcat controller 75-68 angle sensors are not calibrated 75-69 Battery voltage is above the maximum permissible 75-70 Fault recovery mode (also appears after the software update) 75-71 Battery voltage is below the limit 75-72 Pump drive is not calibrated 75-73 mode switch ISO / H switched during operation 75-74 Uncontrolled rotation speed of the right wheel 75-75 Uncontrolled rotation speed of the left wheel 75-76 There are no posts from the controller ACS 75-77 speed sensor signal of the left wheel of the upper limit of the range 75-78 speed sensor signal of the right wheel of the top of the range 75-79 speed sensor signal of the left wheel of the lower boundary of the range 75-80 speed sensor signal of the right wheel of the bottom of the range 75-81 Front right solenoid control retraction shorted to battery 75-82 Front left solenoid control retraction shorted to battery 75-83 Rear right solenoid control retraction shorted to battery 75-84 Rear left solenoid control retraction shorted to battery 75-85 Power "1" 5-volt sensor for the upper limit of the range 75-86 Sensor supply 2 for the upper limit 75-88 controller in programming mode 75-91 Changing the polarity of the left oblique sensor plate 75-92 Changing the polarity of the sensor right oblique plate 75-93 right wheel speed sensor does not respond 75-94 left wheel speed sensor does not respond 75-95 Change of direction in the left wheel speed sensor 75-96 Change of direction in the right wheel speed sensor 75-98 controller in calibration mode 76-73 left panel, the error of the receiver 77-48 Ignition Switch, multi-mode 78-74 Door / locking the lock is opened / closed 80-02 ACD, output «A», the erroneous inclusion 80-03 ACD, output «A», erroneous shutdown Ing. Balzarini www.ingarconsultores.com maximiliano.balzarini@ingarconsultores.com+54 9 11 5656 8006 Página 7 Códigos Error www.ingarconsultores.com 81-02 ACD, exit «B», the erroneous inclusion 81-03 ACD, exit «B», erroneous shutdown 82-02 ACD, output «C», the erroneous inclusion 82-03 ACD, output «C», erroneous shutdown 83-02 ACD, exit «D», the erroneous inclusion 83-03 ACD, exit «D», erroneous shutdown 84-02 ACD, exit «E», the erroneous inclusion 84-03 ACD, exit «E», erroneous shutdown 85-02 ACD (controller attachments), exit «F», the erroneous inclusion 85-03 ACD, exit «F», erroneous shutdown 86-02 ACD, exit «G», the erroneous inclusion 86-03 ACD, exit «G», erroneous shutdown 87-02 ACD, exit «H», the erroneous inclusion 87-03 ACD, exit «H», erroneous shutdown 90-02 Service Output «C», the erroneous inclusion 90-03 Service Output «C», erroneous off wheels 91-02 Service Output «D», the erroneous inclusion 91-03 Service Output «D», erroneous shutdown 92-02 Service Output "E", the erroneous inclusion 92-03 Service Output "E" erroneous shutdown 93-02 Service Output «F», the erroneous inclusion 93-03 Service Output «F», erroneous shutdown
Ing. Balzarini www.ingarconsultores.com maximiliano.balzarini@ingarconsultores.com+54 9 11 5656 8006 Página 8