ACCESSORY ORIENTATION CHART ITEM D/S PART NUMBER QTY DESCRIPTION MAT'L. GR. EST. WT.

PAINT CODE
ITEM SERVICE SIZE REF DEGREE RADIUS 1 B 9281D1A2 1 DOME STANDARD INSTALLATION DETAILS N R
67A DOME SKYLIGHT ASSEMBLY STD. 77.86° 32'-5 5/8" [9896.4mm] DESIGN CRITERIA: 2 B 9281D1A3 1 DOME STANDARD INSTALLATION DETAILS (ACC.) N R
DESIGN (PER API 650 12TH EDITION APPENDIX G) - -
67B DOME SKYLIGHT ASSEMBLY STD. 212.86° 32'-5 5/8" [9896.4mm] 3 WIREROPESS38 58 WIREROPE n3/8" 7X19 STRAND 300 SERIES SS N
WIND DESIGN: 105.12 mph [47 m/s] PER IS875 DESIGN - -
67C DOME SKYLIGHT ASSEMBLY STD. 347.86° 32'-5 5/8" [9896.4mm] 4 3372T45 2 WIRE ROPE CLIP AND THIMBLE KIT 300 SERIES SS N
LIFE: 50 YEARS
68 24" SQ. MANWAY ASSY. 24" SQ. [610mm] 270° 44'-11 5/8" [13706.4mm] 5 - 8201T68 1 ROPE GRAB CLIP 3/8" 300 SERIES SS N -
ROOF LIVE LOAD: 20 lbs/ft²
70 24" VENT ASSEMBLY W/ BIRD SCREEN Ø24" [610mm] 32.86° 9'-2 3/4" [2813.2mm] GROUND SNOW LOAD: 0 lbs/ft² 6 B CRGA06 1 CENTER RING TIE OFF 9 N R
71A MAX CLOSED MASTER FLASH Ø8.6" [218mm] 275.65° 47'-7 1/2" [14516.8mm] 0° DESIGN PRESSURE/VACUUM: ATMOSPHERIC 7
71B MAX CLOSED MASTER FLASH Ø20" [20mm] 282.39° 45'-11" [13996mm] OPERATING PRESSURE/VACUUM: ATMOSPHERIC 8 B HC16 81 HUB COVER FOR Ø16" HUBS ALUM 1100-0 3 N -
DESIGN TEMPERATURE: UP TO 200°F 9
OPERATING TEMPERATURE: AMBIENT 9281D3HT1 6061-T6 -
10 B 1 HUB TOP #1-16Ø 7 N
11 B 9281D3HB1 1 HUB BOTTOM #1-16Ø 6061-T6 7 N -
12 B 9281D3HU2 16 HUB UNIVERSAL #2-16Ø 6061-T6 7 N -
13 B 9281D3HU3 16 HUB UNIVERSAL #3-16Ø 6061-T6 7 N -
14 B 9281D3HU4 16 HUB UNIVERSAL #4-16Ø 6061-T6 7 N -
15 B 9281D3HU5 16 HUB UNIVERSAL #5-16Ø 6061-T6 7 N -
16 B 9281D3HU6 16 HUB UNIVERSAL #6-16Ø 6061-T6 7 N -
17 B 9281D3HU7 16 HUB UNIVERSAL #7-16Ø 6061-T6 7 N -
67C 18 B 9281D3HT8 8 HUB TOP #8-16Ø 6061-T6 7 N -
19 B 9281D3HB8 8 HUB BOTTOM #8-16Ø 6061-T6 7 N -
20 B 9281D3HT9 8 HUB TOP #9-16Ø 6061-T6 7 N -
21 B 9281D3HB9 8 HUB BOTTOM #9-16Ø 6061-T6 7 N -
22 B 9281D3HT10 8 HUB TOP #10-16Ø 6061-T6 7 N -
23 B 9281D3HB10 8 HUB BOTTOM #10-16Ø 6061-T6 7 N -
24 B 9281D3HT11 8 HUB TOP #11-16Ø 6061-T6 7 N -
25 B 9281D3HB11 8 HUB BOTTOM #11-16Ø 6061-T6 7 N -
26
27 B 9281D3P1 7 PANEL #1 3003-H16 37 N -
28 B 9281D3P1V 1 PANEL #1V, W/ VENT CUTOUT 3003-H16 34 N -
29 B 9281D3P2 8 PANEL #2 3003-H16 50 N -
30 B 9281D3P3 8 PANEL #3 3003-H16 49 N -
31 B 9281D3P4 8 PANEL #4 3003-H16 50 N -
32 B 9281D3P5 8 PANEL #5 3003-H16 51 N -
71B
33 B 9281D3P6 8 PANEL #6 3003-H16 51 N -
70 34 B 9281D3P7 8 PANEL #7 3003-H16 51 N -
35 B 9281D3P8 8 PANEL #8 3003-H16 -
51 N
36 B 9281D3P9 5 PANEL #9 3003-H16 -
45 N
67A 37 B 9281D3P10 7 PANEL #10 3003-H16 -
71A 43 N
38 B 9281D4P10B 1 PANEL #10B, W/ PIPE CUTOUT 3003-H16 -
40 N
39 B 9281D3P11 7 PANEL #11 3003-H16 -
47 N
40 B 9281D4P11M 1 PANEL #11M, W/ MANWAY CUTOUT 3003-H16 -
81 47 N
41 B 9281D3P12 8 PANEL #12 3003-H16 -
270° 90° 47 N
42 B 9281D3P13 7 PANEL #13 3003-H16 -
43 N
69 68 43 B 9281D4P13B 1 PANEL #13B, W/ PIPE CUTOUT 3003-H16 39 N -
44 B 9281D3P14 8 PANEL #14 3003-H16 43 N -
80 45 B 9281D3P15 8 PANEL #15 3003-H16 42 N -
46 B 9281D3P16 8 PANEL #16 3003-H16 42 N -
47
48 B 9281D3S1 8 BEAM #1 6005A-T6/6061-T6 25 N -
49 B 9281D3S2 8 BEAM #2 6005A-T6/6061-T6 19 N -
50 B 9281D3S3 8 BEAM #3 6005A-T6/6061-T6 30 N -
51 B 9281D3S4 16 BEAM #4 6005A-T6/6061-T6 33 N -
52 B 9281D3S5 16 BEAM #5 6005A-T6/6061-T6 21 N -
53 B 9281D3S6 8 BEAM #6 6005A-T6/6061-T6 29 N -
54 B 9281D3S7 16 BEAM #7 6005A-T6/6061-T6 34 N -
55 B 9281D3S8 16 BEAM #8 6005A-T6/6061-T6 30 N -
56 B 9281D3S9 16 BEAM #9 6005A-T6/6061-T6 21 N -
57 B 9281D3S10 8 BEAM #10 6005A-T6/6061-T6 19 N -
58 B 9281D3S11 8 BEAM #11 6005A-T6/6061-T6 33 N -
59 B 9281D3S12 16 BEAM #12 6005A-T6/6061-T6 32 N -
60 B 9281D3S13 16 BEAM #13 6005A-T6/6061-T6 27 N -
61 B 9281D3S14 16 BEAM #14 6005A-T6/6061-T6 28 N -
67B
62 B 9281D3S15 32 BEAM #15 6005A-T6/6061-T6 45 N -
63
64 B 9281D3BATTENS 1 BATTEN EXTRUSION CUT SHEET 900 N -
65
66 B 9281D4PRGA 1 PIER LAYOUT 468 N R
67 C 9281D3DSLASSY 3 DOME SKYLIGHT ASSEMBLY 121 N R
68 B TCMWSQ24 1 24" SQ. MANWAY ASSY. 45 N R
69 B TCMWSQ24RF 1 24" SQ. MANWAY REINFORCING FLG ALUM 5052-H32 8 N -
70 B VAB24BAL 1 24" VENT ASSEMBLY W/ BIRD SCREEN 41 N R
-
71 SQ951BA-C 2 MAX CLOSED MASTER FLASH EPDM 15 N -
72 - 9281D3901 11 #8 TIN COATED GROUND CABLE W/ 1/4" EYELITS 18" LG -
N
73
74 B 9281D3FL 32 FLASHING 3003-H16 19 N -
75 B 9281D3CF1A 32 COUNTER FLASHING #1A ALUM 3003 4 N -
180° 76 B 9281D3CF1B 32 COUNTER FLASHING #1B ALUM 3003 4 N -
77 -
CFSPL006 64 .050" X 2" X 6" ALUM. ALUM 3003 N -
-
PLAN VIEW 78 CFSPL051 32 .050" X 2" X 51" ALUM. ALUM 3003 -
N
79
80 B 9281D4101 1 L3" X 3" X 3/8", SUPT. ANGLE ALUM 6061-T6 -
12 N
81 B 9281D3102 1 L3" X 3" X 3/8", SUPT. ANGLE ALUM 6061-T6 -
-
15 N
SURFMNTHNGALNH
82 4 ALUM. SURFACE MOUNT HINGE (NO HOLES) ALUM 6061-T6 N -
83
- BLTHS05003750F593C
70 84 68 BOLT 1/2" X 3 3/4" F593C N -
- WSHLS0500188
85 68 WASHER 1/2" (LOCK) 18-8 N -
- NUTHS0500316
86 68 NUT 1/2" A316 N -
-
BLTHS10MM40MMA270 -
SS Bolt 10mm x 40mm [1 1/2"] A270 N
19'-3 3/8" [5877.7 mm] DOME HEIGHT

87 -
WSHLS10MMA2 4175
88 - 4175 Washer 10mm (Lock) A2 N -
NUTHS10MMA4
89 -
BLTHS12MM40MMA270 4175 Nut 10mm A4 N -
-
WSHLS12MMA2 SS Bolt 12mm X 40mm [1 1/2"] A270 N -
90 1344
-
NUTHS12MMA4 A2 N -
91 1344 Washer 12mm (Lock)
67B - SCWTRI02500750188 N -
68 92 1344 Nut 12mm A4
- SCWTEK140750188 N -
93 4480 TRILOBE 1/4" X 3/4" W/ WASHER #14 18-8
71B - SCWTEK141250188 N -
71A 94 669 TEK SCREW 3/4" W/ WASHER 18-8
- SCWTRI02502500188 N -
95 1162 #14TEK SCREW 1 1/4" W/ WASHER 18-8
* -
RIVDAL38198 N -
96 90 1/4" X 2 1/2" TRILOBE SCREW W/ WASHER 18-8
-
RIVPALSL316250 N -
97 404 DRIVE RIVET ALUMINU
-
BLTHSM720MMA2 N -
98 - 303 POP RIVET M -
WSHCS7MMA2 N
99 -
PEC890SAA20OZ 52 7mm Bolt X 20mm 7mm ALUMINU N -
100 52 WASHER CAULKING / M A2 N -
101 66 PECORA A2
ULM SILICONE
* #14 X 1 1/2" TEK SCREW TO BE USED IN LIEU OF #14 X 1 1/4" AS NEEDED.
100'-0 13/16" [30500 mm] NOMINAL TANK I.D.

PLAN VIEW

ASSY. WT: 16780#


PARENT: THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANK CUSTOMER NAME: TANK TECH ASIA PVT LTD CERTIFIED: APPROVED FOR CONSTRUCTION
TOLERANCES UNLESS OTHERWISE NOTED COLUMN TOLERANCES MANUFACTURER AND/OR ITS AFFILIATES. ANY
ANGULAR DEVIATION PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES LINEAR TOLERANCE: OTHER USE, RETENTION, DISSEMINATION, ALUMINUM GEODESIC PROJ # 09281 JOB # D4
X = ±1.0° / X.X = ±0.5° 0 - 4" 4" - 48" 48" - 130" FORWARDING, PRINTING OR COPYING OF THIS PROJECT NAME: 7 DOMES FOR TTA ICO TENDER
130" - 240" 240"+ +0" / -1/8" DOCUMENT TO UNAUTHORIZED PARTIES IS 3609 NORTH 16TH ST . PARSONS, KANSAS 67357 DOME FOR A Ø100'-0 13/16"
1/32" STRICTLY PROHIBITED, WITHOUT THE 620.423.3010 . FAX: 620.423.3999
STEEL TANK
LINEAR TOLERANCE:
1/16" 1/8" 5/32" 3/16" SQUARENESS TOLERANCE: EXPRESSED WRITTEN CONSENT OF TANK
0 RELEASED FOR FABRICATION 10/28/2022 JLS MMP PROJECT LOCATION: CHENNAI, INDIA DWG # 9281D4ASSEM
HOLE TO HOLE TOLERANCE: 1/32" 1/32" 1/32" 1/16" 1/16" ±3/32" MANUFACTURER. REV REVISION DESCRIPTION DATE DRAWN BY CHECKED BY DWG SIZE: D SCALE: NTS
PLACE 3 #14 x 1 1/4" TEK SCREWS EITHER SIDE OF SEAM IN
DOME FLASHING (TO BE INSTALLED CLOCKWISE
SUPPORT BLOCK. PREDRILL 3/16"Ø HOLES
TO ACHIEVE CORRECT LAP)
1/4" X 3/4" TRILOBE SCREW W/ WASHER
#14 X 1 1/4" SS TEK SCREWS #14
BATTEN
HUB COVER X 3/4" SS TEK SCREWS TYPICALLY SPACED AT 8" BUT
USE AS REQ'D TO CLOSE ALL RETAINER & FLASHING GAPS TANK EAVE ANGLE
FIELD APPLY SEALANT TO CREATE WEATHERPROOF
SEAL BETWEEN FLASHING AND HUB COVER
BEND UNDER LAP TAB AND APPLY SEALANT AS REQ'D FOR VENTED COUNTER FLASHING TO
NYLON FLASHING SHIM WEATHER TIGHT SEAL AT ALL FLASHING JOINTS BE INSTALLED BETWEEN EAVE
ANGLE AND SPLICE PL
#14 X 1 1/4" SS TEK SCREWS FIELD CUT COUNTER FLASHING STRIP TO CORRECT LENGTH
AT PIER FLASHING SHIMS AND SEAL ANY GAPS BETWEEN COUNTER FLASHING JOINTS. FLASHING NOT DESIGNED AS A WALKING SURFACE.
USE SEALANT AND FASTEN WITH ALUMINUM RIVETS. LADDER PLATFORMS MUST EXTEND OVER
#14 X 1 1/4" SS TEK SCREWS AT SEAM LOCATIONS FLASHING.
PIER
SEALANT TO BE APPLIED AT FLASHING SEAM
DOME FLASHING
TIGHTEN AFTER ASSEMBLY DETAIL B
FLASHING & COUNTER FLASHING INSTALLATION

COUNTER FLASHING PIER SHIM (NEOPRENE)

1/4" X 2 1/2"
SEALANT AROUND ENTIRE
TRILOBE SCREW
COUNTER FLASHING PL HUB COVER PERIMETER
W/ WASHER
#14 X 3/4" SS TEK SCREWS SPACED APPLY SEALANT BETWEEN WASHER AND HUB COVER
AROUND AT 8" OR AS REQ'D
REF.
1"

75 X 75 X 6
EAVE ANGLE HUB COVER
TOP HUB FIELD APPLY SEALANT ON COVER,
COUNTER FLASHING SPLICE:FIELD CUT COUNTER HUB, BATTEN AND PANEL GAPS
FLASHING STRIP TO CORRECT LENGTH AND SEAL DOME PANEL
ANY GAPS BETWEEN COUNTER FLASHING JOINTS.
USE SEALANT AND FASTEN WITH ALUM RIVETS.
DETAIL A
FLASHING INSTALLATION

BOTTOM HUB

DOME PANEL
DETAIL D
3/8" DRIVE RIVET THRU PANEL INTO HUB TYPICAL DOME BEAM CONNECTION 10mm SS BOLTS, WASHERS, & NUTS. EACH END OF
ALIGNMENT HOLE. TYP ALL 3 PANEL CORNERS BEAM FLANGE TO DOME HUB MIN OF 4 PLC'S TOP
& BOTTOM FLANGE

HUB COVER NOTES:


ALL MATERIAL IS MILL FINISH ALUMINUM UNLESS NOTED
DOME PANEL .050" ALUM PANEL CORNER MARKS ARE PANELS, FLASHING AND HUB COVERS 3003-H16 OR 5052-H32
FIELD APPLY SEALANT ON COVER, ORIENTATION MARK IS ON HUBS AND PLATES 6061-T6 OR 5052-H32
HUB, BATTEN AND PANEL GAPS LABELED W/ "P" PANEL NUMBER
1/4" X 3/4" TRILOBE SCREW AND "B" BEAM NUMBER OPPOSITE THE RIGHT SIDE OF THE BEAM AND BATTEN STRIPS 6005A-T6 OR 6061-T6
W/ WASHER SIDE OF PANEL CORNER HOLE WHEN VIEWED
FROM THE TOP FASTENERS
BATTEN BAR W/ GASKET 10mm BOLTS, WASHERS, & NUTS
FLASHING OVERLAPS HUB P1 B1 12mm BOLTS, WASHERS, & NUTS
DOME STRUT (FIELD CUT AS NEEDED) PIER ANCHOR NOTES
1. ANCHOR POINT FOR EACH PIER HAVE TO MEET THE STRUCTURAL
1/4" X 2 1/2" TRILOBE SCREW W/ WASHER APPLY 12mm BOLTS, WASHERS, & NUTS REQUIREMENTS FOR ANCHORING.
SEALANT BETWEEN WASHER AND HUB COVER FASTENER TYP ALL HUB TO STRUT 2. ANCHORING POINT FOR EACH PIER MUST BE WITHIN +/- ½” OF THE DESIGNED
CONNECTIONS RADIUS SHOWN ON THE APPROVAL AND INSTALLATION DRAWINGS.
TOP HUB PIER
3. LEVELNESS TOLERANCE OF ANCHORING SURFACE MUST NOT EXCEED +/-⅛”
DETAIL DOME FLASHING BETWEEN ADJACENT PIERS AND THE TOTAL DIFFERENCE FOR THE WHOLE
C
TYPICAL HUB, COVER & BATTEN
INSTALLATION DETAIL E ANCHORING SURFACE MUST BE LESS THAN +/-¼”.
PANEL LABELING 4. TANK WALL ROUNDNESS MUST BE WITHIN +/-1” OF THE DESIGNED RADIUS AS
SHOWN ON THE APPROVAL AND INSTALLATION DRAWINGS.
TOTAL WT: PARENT: THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANK
PRELIMINARY: NOT APPROVED FOR CONSTRUCTION
***DO NOT SCALE*** MANUFACTURER AND/OR ITS AFFILIATES. ANY DOME STANDARD
TOLERANCES UNLESS OTHERWISE NOTED
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS
ANGULAR DEVIATION PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THIS INSTALLATION DETAILS PROJ # 09281 JOB # D1
X = ±1.0° / X.X = ±0.5° 0 - 4" 4" - 48" 48" - 130" 130" - 240" 240"+ DOCUMENT TO UNAUTHORIZED PARTIES IS 3609 NORTH 16TH ST . PARSONS, KANSAS 67357
1 RELEASE FOR FABRICATION 10/20/2022 MMP JLS ACCESSORIES
STRICTLY PROHIBITED, WITHOUT THE 620.423.3010 . FAX: 620.423.3999
3RD ANGLE LINEAR TOLERANCE: 1/32" 1/16" 1/8" 5/32" 3/16" EXPRESSED WRITTEN CONSENT OF TANK 0 NOT APPROVED FOR CONSTRUCTION 9/14/2022 MMP CW DWG # 9281D1A2
PROJECTION HOLE TO HOLE 1/32" 1/32" 1/32" 1/16" 1/16" MANUFACTURER. REV REVISION DESCRIPTION DATE DRAWN BY CHECKED BY DWG SIZE: B SCALE: NTS
TOLERANCE:
LOOP CABLE AND THIMBLE
(3) 3/8" 304SS THIMBLE AND CLIP KIT, THROUGH CENTER SUPPORT RING 8
INSTALL CLIPS MAX OF 5" APART DOME MANWAY

3/8" WIRE ROPE GRAB 304 SS


INSTALL PER MFG. INSTRUCTIONS
12 9
3/8"Ø S.S. PANEL #
3" X 3" X 3/8" ANGLE USE SEALANT
P12
(SEE DETAIL 'B')
HUB # ATTACH WITH 10mm
WIRE 5 SS BOLTS, WASHERS, & NUTS
9 9
DOME PANEL
STRUT & BATTEN #
DETAIL H
DOME MANWAY 30" SQ
LEGEND WITH REINFORCEMENT ANGLE

EXTEND ROPE TO ACCESS LADDER FIELD APPLY SEALANT BETWEEN CENTER


OR PLATFORM AND CUT TO SUPPORT BLOCK AND HUB COVER DOME PANEL
LENGTH, ATTACH TO PLATFORM 3" X 3" X 3/8" ALUM. REIN. ANGLE DOME VENT
DETAIL DOME PANEL INSTALL ANGLE FLUSH WITH
A
CENTER SAFETY GRAB CABLE INSTALLATION DOME PANEL ATTACH WITH 10mm
SS BOLTS, WASHERS, & NUTS
DOME PANEL

10mm SS BOLTS, DOME PANEL


DOME ACCESSORY 3" X 3" X 3/8" ALUM WASHERS & NUTS
REINFORCING ANGLE 3" X 3" X 3/8" ANGLE USE SEALANT
DRILL HOLES IN HINGE, (SEE DETAIL B)
FIELD CUT TO FIT BEAM ANGLE, AND BEAM AS NEEDED
BETWEEN DOME
STRUTS WITH DETAIL G
ALUM. HINGE
MINIMUM ALUMINUM DOME VENT
CLEARANCE (HEELS SECTION D-D WITH REINFORCEMENT ANGLE
TYPICAL ALUM
IN) ANGLE SUPT
INSTALLATION

UTILIZE #SCWTRI02501000188
FOR ATACHMENT OF #CFSPL006 PIER ASSEMBLY
RUBBER MASTER ON BOTH SIDES OF PIER BASE
APPROXIMATE 1" GAP
IF ACCESSORY CUT EDGE IS FLASH BOOT (TO BE REMOVE AFTER DOME
BETWEEN DOME ACC. UTILIZE 1/2" X 3 3/4"
WITHIN 18" OF STRUT, SECOND IS INSTALLED)
AND SUPT. ANGLE SS BOLTS,
SUPT. ANGLE NOT REQ'D. #14 X 1 1/4" WASHERS, & NUTS
TEK SCREW FOR ATTACHMENT
GROUNDING CABLE
DETAIL B PIPING AND COMPONENTS TO BE ATTACHED PIER SHIM
TYPICAL ACCESSORY PENETRATION NOT TO BE SUPPORTED BY PIER BY SELF-
REINFORCEMENT ANGLE DOME TAPING SCREW,
DOME PANEL OTHER END
FIELD CUT ATTACHED BY
DOME SKYLIGHT BY CUSTOMER
(ASSEMBLED IN SHOP) DETAIL J
FLASHING BOOT DETAIL TYPICAL PIER ATTACHMENT DETAILS
EAVE ANGLE

SKYLIGHT SUPT. ANGLE

***DO NOT SCALE***


DETAI
TOLERANCES UNLESS OTHERWISE NOTED
L A DOME
SKYLIGHT
TOTAL WT: PARENT:
THE INFORMATION ON THIS DOCUMENT IS CONFIDENTIAL
PRELIMINARY: NOT APPROVED FOR CONSTRUCTION
PROPERTY OF TANK MANUFACTURER AND/OR ITS DOME STANDARD
AFFILIATES. ANY
DRAWING IN INCHES
ANSI/ASME Y14.1 STANDARDS
ANGULAR DEVIATION PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THIS
2 RELEASE FOR FABRICATION 10/20/2022 MMP JLS
INSTALLATION DETAILS PROJ # 09281 JOB # D1
1
X = ±1.0° / X.X = ±0.5° 0 - 4" 4" - 48" 48" - 130" 130" - 240" 240"+ DOCUMENT TO UNAUTHORIZED PARTIES IS 3609 NORTH 16TH ST . PARSONS, KANSAS 67357 REVISED FOR RE-SUBMIT 9/27/2022 MMP CW ACCESSORIES
620.423.3010 . FAX: 620.423.3999
3RD ANGLE LINEAR TOLERANCE: 1/32" 1/16" 1/8" 5/32" 3/16" STRICTLY PROHIBITED, WITHOUT
EXPRESSED WRITTEN CONSENT OF TANK
THE 0 NOT APPROVED FOR CONSTRUCTION 9/14/2022 MMP CW DWG # 9281D1A3
PROJECTION HOLE TO HOLE 1/32" 1/32" 1/32" 1/16" 1/16" MANUFACTURER. REV REVISION DESCRIPTION DATE DRAWN BY CHECKED BY DWG SIZE: B SCALE: NTS
TOLERANCE:
ITEM D/S PART NO. QTY DESCRIPTION MAT'L. GR. EST. WT. PAINT CODE
4 3 1 B CRSB06 1 CENTER RING SUPPORT BLOCK 2 X 2 X 7.875 LG. 6061 T6 4 - -
2 - 3046T75 1 LARGE OPENING HOIST RING 17-4 PH SS 5 - -
3 3 - WSHLS0750304 1 WASHER LOCK 3/4" 304SS 304SS - - -
4 - BLTHS07501500304 1 BOLT 3/4" X 1 1/2" HEX HD 304SS 304SS - - -
3

APPLY SEALANT BETWEEN


1
HUB COVER AND HOIST
RING BASE
FIELD DRILL
FOR 3/4" BOLT
HUB COVER

A A

TOP & BTM


HUBS

3
4
CENTER RING SAFETY TIE OFF SECTION A-A
POINT AT APEX 5000# MAX LOAD

TOTAL WT: 9 PARENT: --- THE INFORMATION ON THIS DOCUMENT IS


CONFIDENTIAL PROPERTY OF TANK
6 UPDATED BORDER 10/22/2020 BLD JWC
CERTIFIED: APPROVED FOR CONSTRUCTION
TOLERANCES UNLESS OTHERWISE NOTED 5 UPDATE BORDER 9/20/2020 PROG AUTO
***DO NOT SCALE*** MANUFACTURER AND/OR ITS AFFILIATES. ANY CENTER RING GENERAL
DRAWING IN INCHES ANGULAR
DEVIATION PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES OTHER USE, RETENTION, DISSEMINATION, 4 HARDWARE UPDATE 6/28/2016 MLH JLP PROJ # --- JOB # ---
ANSI/ASME Y14.1 STANDARDS ±1.0° / ±0.5° 48" 240 0"+ OR COPYING OF THIS
PROJECTI FORWARDI
X= X.X = 0 - 4" 4" - 48" - 130" 130" - " 24 NG, DOCUMENT TO UNAUTHORIZED
3RD ANGLE ON
LINEAR TOLERANCE: 1/32" 1/16" 1/8" 5/32" 3/16" STRICTLY PROHIBITED, WITHOUT THE 620.423.3010 . FAX: 620.423.3999 PRINTING PARTIES IS
3609 NORTH 16TH ST . PARSONS,
EXPRESSED WRITTEN CONSENT OF TANK 2 SWITHCED TO NEW BORDER 9/8/2014 BDS JLP
KANSAS 67357 ARRANGEMENT FOR
3 HARDWARE UPDATE 6/16/201 MLH JLP SAFETY TIE
6
OFF
DWG CRGA06
#
ITEM D/S PART NUMBER QTY DESCRIPTION MAT'L. GR. EST. WT. PAINT CODE
1 B 9281D3PRASM 32 PIER ASSEMBLY 13 - R
2 B 9281D3PRSHIM 32 1/4" NEOPRENE SHIM NEOPRENE 1 - -
0° 3 B 9281D3CF3 32 COUNTER FLASHING #3 ALUM 3003 1 - -

A

n100'-6 13/16" O.D. 1'- 3/8" 9'-3 5/16"


n100'-4 13/16" B.C.
n100'- 13/16" I.D. 6 3/8" 8'-9 3/8"
R50'-2 3/8" B.C.

DETAIL A

270°
90°
1

2
3

B B
1

2
ISOMETRIC VIEW B-B

EXISTING EAVE ANGLE


TANK INT.

SECTION B-B
TYP. (32) PLCS

180°
PLAN VIEW

TOTAL WT: 468 lbmass PARENT: THE INFORMATION ON THIS DOCUMENT IS


CONFIDENTIAL PROPERTY OF TANK
CERTIFIED: APPROVED FOR CONSTRUCTION
***DO NOT SCALE*** TOLERANCES UNLESS OTHERWISE NOTED MANUFACTURER AND/OR ITS AFFILIATES. ANY
DRAWING IN INCHES ANGULAR DEVIATION PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THIS
PROJ # 09281 JOB # D4
ANSI/ASME Y14.1 STANDARDS PIER LAYOUT
X = ±1.0° / X.X = ±0.5° 0 - 4" 4" - 48" 48" - 130" 130" - 240" 240"+ DOCUMENT TO UNAUTHORIZED PARTIES IS 3609 NORTH 16TH ST . PARSONS, KANSAS 67357
STRICTLY PROHIBITED, WITHOUT THE 620.423.3010 . FAX: 620.423.3999
3RD ANGLE LINEAR TOLERANCE: 1/32" 1/16" 5/32" 1/8" 3/16" EXPRESSED WRITTEN CONSENT OF TANK
0 RELEASED FOR FABRICATION 10/28/2022 JLS MMP DWG # 9281D4PRGA
PROJECTION HOLE TO HOLE 1/32" 1/32" 1/32" 1/16" 1/16" MANUFACTURER. REV DWG SIZE: B SCALE: NTS
TOLERANCE:
I

3RD ANGLE 0 0
620.423 3010 .
FAX: 620.423.3999
STRICTLY PROHIBITED, WITHOUT THE
LINEAR TOLERANCE: 1/32" 1/16" 5/32" 1/8" 3/16" EXPRESSED WRITTEN CONSENT OF TANK
3609 NORTH 16TH ST . PARSONS, KANSAS 67357 RELEASED FOR
FABRICATION
10/27/20JLS
22
MMP DWG #
9281D3PRASM TEM D/S PART NUMBER QTY DESCRIPTION MAT'L. GR. EST. WT. PAINT
PROJECTION HOLE TO HOLE 1/32" 1/32" 1/32" 1/16" 1/16" MANUFACTURER. REV REVISION DESCRIPTION DATE DRAWN BY CHECKED BY DWG SIZE: B SCALE: NTS -
TOLERANCE:
1 B 9281D3PR1 1 PIER BASE (DIE #18518) X 7 3/8" LG. 6061-T6 6
2 B 9281D3PR2 2 PIER SHOE (DIE #18519) X 2 1/4in LG 6061-T6 -
3 - 9281D3PR3 1 PIER LINK (DIE #18517) X 2 1/4in LG 6061-T6 -
4 B 9281D3PR4 1 PIER BEAM I-6 X 19 15/16" LG. 6061-T6 6 -
5 B SHIMHDPE383A 1 .375 THK FLASHING SHIM NYLON 6/10 -
6 - 9281D3PR2_PTFETAPE 1 PTFE TAPE .020 THK X 3in X 2 1/4in LG - -
7 - 9281D3PR2_PTFETAPE2 2 PTFE TAPE .020 THK X 1in X 2 1/4in LG - -
8 - PTFETAP020315 1 PTFE TAPE .020 THK X 3" X 7 3/8" LG. - -
9 - PTFETAP0203415 2 PTFE TAPE .020 THK X 3/4" X 7 3/8" LG. - -
10 - BLTHS07502000F593D 1 BOLT 3/4" x 2" HEX HD F593D -
12 - NUTHS0750316 1 NUT 3/4" HEX HD A316 -
20 - WSHLS0750304 1 WASHER (LOCK) A304 -
21 - RIVPAL316750 2 RIVET POP DOME HD 3/16" DIA. (GRIP 5/8"-3/4") ALUM -

4 5

5 21
1

21 21

I OMETRIC VIEW
ITEM PE DETAIL
(OTHER COMPONENTS HIDDEN FOR CLARITY)

20 12 10

2 2

1 1 3
3
7 7

2 2
2 1/4" REF
TAPE DETAIL
(OTHER COMPONENTS HIDDEN FO R C LARITY)
FRONT ASS EMBLY VIEW
SIDE ASSE MBLY VIEW

TOTAL WT: 1 3 lbmass PARENT: THE INFORMATION ON THIS DOCUMENT IS


CONFIDENTIAL PROPERTY OF TANK
CERTIFIED: APPROVED FOR CO NSTRUCTION

CONN ECTIO N
***DO NOT SCALE*** TOLERANCES UNLESS OTHERWISE NOTED MANUFACTURER AND/OR ITS AFFILIATES. ANY
DRAWING IN INCHES ANGULAR DEVIATION PERMI SSIBLE DEVIATION NOMINAL LENGTH IN INC ES OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THIS
PROJ # 09 281 JOB # D3
ANSI/ASME Y14.1 STANDARDS PIER ASSEMBLY
X = ±1.0° / X.X = ±0.5° 0 - 4" 4" - 48" 48" - 130" 130" - 240" 24 "+ DOCUMENT TO UNAUTHORIZED PARTIES IS AFFILI ATE GR OUP
ITEM D/S PART NUMBER QTY DESCRIPTION MAT'L. GR. EST. WT. PAINT CODE
1 B 9281D3SLEXT1 1 DOME SKYLIGHT EXTRUSION X 91 11/16" LG 6005-AT61 4 N -
HUB IDENTIFICATION 2 B 9281D3SLEXT2 1 DOME SKYLIGHT EXTRUSION X 12'-9 3/8" LG 6005-AT61 7 N -
MARK 3 B 9281D3SLEXT3 1 DOME SKYLIGHT EXTRUSION X 12'-9 3/8" LG 6005-AT61 7 N -
4 B 9281D3SLGL 1 DOME SKYLIGHT GLASS, 1/4" ACRYLIC Plexiglass 13 N -
5 B 9281D3SLP1 1 DOME SKYLIGHT END CAP ALUM 3003 N -
6 B 9281D3SLP2 1 DOME SKYLIGHT END CAP ALUM 3003 N -
7 B 9281D3SLP3 1 DOME SKYLIGHT END CAP ALUM 3003 N -
8 B 9281D3ANG1 1 DOME SKYLIGHT SUPT, L3" X 3" X 3/8" X 79 15/16" LG ALUM 6061-T6 15 N -
9 B 9281D3ANG2 1 DOME SKYLIGHT SUPT, L3" X 3" X 3/8" X 79 15/16" LG ALUM 6061-T6 15 N -
10 B 9281D3ANG3 1 DOME SKYLIGHT SUPT, L3" X 3" X 3/8" X 51 3/4" LG ALUM 6061-T6 10 N -
11 B 9281D3SLCLP1 1 SUPT. CLIP ALUM 5052-H32 1 N -
12 B 9281D3SLCLP2 1 SUPT. CLIP ALUM 5052-H32 1 N -
13 B 9281D3SLCLP3 1 SUPT. CLIP ALUM 5052-H32 1 N -
14 C 9281D3SLRA 1 SKYLIGHT RETAINING FLANGE ASSY. 45 N -
APPLY SEALANT
15 - SCWTEK121000316 91 TEK SCREW #12 X 1" SS HEX HEAD A316 N -
BETWEEN SKYLIGHT 14
& RETAINING ANGLE FRAME 16 - WSHCS12316 91 #12 SEALING NEOPRENE WASHER A316 N -
10 17 - 86573MVHBTAPE 1 3M VHB TAPE DOUBLE SIDED - 2" WIDE X 58 LINEAR FT - N -
18 - PEC890SAA20OZ 6 PECORA 890 SILICONE SEALANT 20oz SG TUBE ALUM - N -
*
A

A
17

NOTE: ASSEMBLED IN SHOP

* APPLY DBL SIDED TAPE TO TOP OF SUPPORT ANGLE UNDER GLASS.

14

B
B

HUB IDENTIFICATION
HUB IDENTIFICATION
MARK
MARK

TOP ASSY. VIEW

3
2 C
14

ISOMETRIC VIEW
4

APPLY SEALANT 2

4 14
OUTSIDE ISOMETRIC VIEW A
10

14 15 16

16 15

13 10 12 4 12 2

2
SECTION A-A
4 14
1 TYP (4) PLCS
15 16 -@ CLIP TO EXT.
5 CONNECTION
9
8
DETAIL C 2
SIMILAR (3) PLCS 10

HLS ARE PRE-DRILLED


FOR ALIGN PURPOSES 16 15
4

INSIDE ISOMETRIC VIEW A


5/16" TYP

11
GAP

7 5
1 2 ISOMETRIC VIEW B
91 1/2"
16 15 CAULK
TOP (2) SCREWS TO BE 14
TOP ASSY. VIEW 15 16 -INSTALLED THROUGH
TOP SUPPORTS NOT SHOWN FOR CLARITY ITEM #14 COVER 4

1
2
5

DETAIL C SECTION B-B


FRONT ASSY. VIEW ITEM 14 HIDDEN FOR CLARITY

TOTAL WT: 121 lbmass


***DO NOT SCALE*** PARENT: THE INFORMATION ON THIS DOCUMENT IS
CONFIDENTIAL PROPERTY OF TANK
CERTIFIED: APPROVED FOR CONSTRUCTION
TOLERANCES UNLESS OTHERWISE NOTED

CO
MANUFACTURER AND/OR ITS AFFILIATES. ANY

X = ±1.0° / X.X = ±0.5° 0 - 4" 4" - 48" 48" - 130" 130" -


N NECTIO
DRAWING IN INCHES OTHER USE, RETENTION, DISSEMINATION, FORWARDING, PRINTING OR COPYING OF THIS DOCUMENT TO UNAUTHORIZED PARTIES IS
ANGULAR DEVIATION PERMISSIBLE DEVIATION NOMINAL
ANSI/ASME Y14.1 STANDARDS 240" 240"+
LENGTH IN INCHES
AFFILIATE GROUP
N DOME SKYLIGHT ASSEMBLY
PROJ # 09281 JOB # D3
STRICTLY PROHIBITED, WITHOUT THE
3RD ANGLE LINEAR TOLERANCE: 1/32" 1/16" 5/32" 1/8" 3/16" EXPRESSED WRITTEN CONSENT OF TANK
3609 NORTH 16TH ST . PARSONS, KANSAS 67357
620.423.3010 . FAX: 620.423.3999
0 RELEASED FOR FABRICATION 10/27/2022 JLS MMP DWG # 9281D3DSLASSY
PROJECTION HOLE TO HOLE TOLERANCE: 1/32" 1/32" 1/32" 1/16" 1/16" MANUFACTURER. REV REVISION DESCRIPTION DATE DRAWN BY CHECKED BY DWG SIZE: C SCALE: NTS
ITEM D/S PART NUMBER QTY MAT'L. GR. EST. WT. PAINT CODE
1 B TCMW24BASE 1 14 N -
2 B TCMW24COVER 1 21 N -
3 - TCMW24SEAL 10 ( 1 N -
4 - BLTHS03751500304 3 A304 N -
5 - WSHLS0375304 3 A304 N -
6 - NUTHS0375316 5 A316 N -

31" O.S. SQ.

(6) SPCS @ 4" = 24" TYP


1 1/4" 1 1 /4"
TYP TYP

6
5 4
OOSE FIT
DBL NUT L
CONNE CTION
PLCS
TYP (2)
24" SQ. OPENING

4 6
5
A
A
ISO

(2 8) n 7/16" HLS
TOP ASSY. VIEW

4 5/8"
4 6

24" SQ. OPENING


1

FRONT ASSY. VIEW

PARENT: T HE INFORMATION ON THIS DOCUMENT IS


IFIED: APPROVED FOR CONSTRU CTION
TOTAL WT: 45 lbmass C ONFIDENTIAL PROPERTY OF TANK
TOL ERANCES UNLESS OTHERWISE NOTED MANUFACTURER AND/OR ITS AFFILIATES. R ANY
***DO NOT SCALE*** GULAR DE VIATIO THEUSE, RETENTION, DISSEMINATION , PROJ # - JOB # -
DRAWING IN INCHES AN PERMISSIBLE DEVIATION NOMINAL LENGTH IN I NC HES OORWARDING, PRINTING OR COPYING OF THIS
ANSI/ASME Y14.1 STANDARDS ±1.0° / X.N .5° 24 0"+ SQ. MANWAY ASSY.
X= 0 - 4"PR
4" - 48"CT48" - 130"
N 130" - 240"
O O
F OCUMENT TO UNAUTHORIZED PARTIES S
LE TOLERANCE: 36
1/32" 1/32 1/32" 1/16"
X = ±0 L
D
09 NORTH 16TH ST . PARSONS, KANSAS 67357
3RD ANGLE LINEAR TOLERANCE: OJE IO E H 1/32" 1/16" " 5/32" 1/8" 3/16"
H T O
1/16" 62
0 7/ JLS MMP
STRICT
0.
23. 1/ DWG # TCM
LY 30 DWG SIZE: B SCALE: NTS
PROHIB 10
REL
EAS
2
0 WSQ
ITED, .
WITHO FAX
ED
FOR
2
2
24
UT THE :
62 FAB
EXPRE 0. RIC
SSED 23. ATI
WRITT 39 ON
EN 99
CONSE REV
NT OF
TANK
MANU
FACTU
RER.
ITEM D/S PART NO. QTY DESCRIPTION MAT'L. GR. EST. WT. PAINT CODE
1
B VNB24AL 1 24" VENT NECK W/ FLANGED BOTTOM ALU 15 - -
2
B VCA24AB 1 24" ALUM. VENT CAP ASSEMBLY W/ BIRD SCREEN M 26 - -
3
B GSKT24VAI 1 GASKET FOR 24" VENT ASSEMBLY ALU - - -
2 1 4
- BLTHS05002250304 3 BOLT 1/2" X 2 1/4" HEX HD (304SS) M - - -
2 1 5
- WSHFS0500304 5 WASHER FLAT 1/2" (304SS) EPDM - - -
2 1 6
- NUTHS0500316 5 NUT 1/2" HEX HD (316SS) A304 - - -
A304
A316

5 4

5 6 6

SECTION A-A
DOUBLE NUT (1)
SIDE FOR HINGE
BIRD SCREEN

A A

SEE A3 FOR ATTACHMENT DETAILS


DOME PANEL AND CONNECTION HARDWARE

TOTAL WT: 41 PARENT: --- THE INFORMATION ON THIS DOCUMENT IS 5 CHANGE HARDWARE CALLOUT 9/27/2022 MMP JWC
CERTIFIED: APPROVED FOR CONSTRUCTION
***DO NOT SCALE*** CONFIDENTIAL PROPERTY OF TANK
TOLERANCES UNLESS OTHERWISE NOTED 4 FIXED REVS. 5/24/2021 BLD JWC
MANUFACTURER AND/OR ITS AFFILIATES. ANY 24" VENT ASSEMBLY W/ BIRD
DRAWING IN INCHES ANGULAR DEVIATION PERMISSIBLE DEVIATION NOMINAL LENGTH IN INCHES OTHER USE, RETENTION, DISSEMINATION,
FORWARDING, PRINTING OR COPYING OF THIS
3 UPDATE BORDER 9/21/2020 PROG AUTO
SCREEN PROJ # --- JOB # ---
ANSI/ASME Y14.1 STANDARDS
X = ±1.0° / X.X = ±0.5° 0 - 4" 4" - 48" 48" - 130" 130" - 240" 240"+ DOCUMENT TO UNAUTHORIZED PARTIES IS 3609 NORTH 16TH ST . PARSONS, KANSAS 67357 2 REVISED HARDWARE 2/22/2018 MLH JWC

3RD ANGLE LINEAR TOLERANCE: 1/32" 1/16" 1/8" 5/32" 3/16" STRICTLY PROHIBITED, WITHOUT
EXPRESSED WRITTEN CONSENT OF TANK
THE 620.423.3010 . FAX: 620.423.3999
1 HARDWARE UPDATE 8/30/2016 ML JLP DWG # VAB24BAL
H
PROJECTION HOLE TO HOLE 1/32" 1/32" 1/32" 1/16" 1/16" MANUFACTURER. REV REVISION DESCRIPTION DATE DRAWN BY CHECKED BY DWG SIZE: B SCALE: NTS
TOLERANCE:

You might also like