Professional Documents
Culture Documents
Contents hide
1 Introduction
1.1 1. Full form of MES and ERP?
1.2 2. Full form of SIS?
1.3 3. How will conductivity measure?
1.4 4. Why is only 24 DC voltage used in the control cabinet?
1.5 5. Why is a 20mA signal used in 4-20 mA standard signal?
1.6 6. What is the use of MES and ERP?
1.7 7. Most Popular MES and ERP software solution provider companies
1.8 8. Which standards are followed for plant functional safety?
1.9 9. Create logic gates using Ladder Logic programming
1.10 10. Create a square Wave generator using ladder logic
2 EndNote: –
Introduction
This post is based on my latest interview experience. In this post, you can find Interview Questions related to
Instrumentation and Automation.
If you give the right answer to these questions, it will give you an unfair advantage in the interview.
so, I will provide how to give answers to it. Maybe in your next interview, these types of questions will be asked.
This question is not asked in every interview but in some cases, these types of questions are asked by the
interviewer and then you will be stuck.
And this question is also based on my latest interview experience in a pharmaceutical company.
Ans: –
Ans: –
A safety instrument system is an added layer of protection for critical processes. where an extra layer of
protection is needed if any functioning part fails.
Visit Exida
Ans: –
Conductivity is the inverse of resistivity so for measuring conductivity you have to find resistivity.
To find the resistivity of the medium you have to find resistance between two electrodes. and by using this
equation you can find resistivity by knowing the resistance value
R= Resistivity * L / A
R=V/I
Conductivity = 1 / Resistivity
Ans: –
Standardize: – Most DC devices are operated on 24 DCV like Relay and Communication Card.
Heat: – The heating of circuits is less compared to higher voltage operating devices.
if you know about almost all microcontrollers operating on a 5V DC signal. Due to the 250Ohm resistance in PLC
input card voltage drop across register is become 5V when 20mA is passing in the loop.
And another reason is safety because the human heart can only stand up to 30mA current more than 30mA
current leads to Heart failure.
Ans: –
MES and ERP are the upper layers of industrial automation. MES and ERP operate on an enterprise level and
transfer commands to the factory floor. To learn more about MES software please check out our post on MES
software
MES: –
• Reduce paperwork
• MES helps the entire project lifecycle for less downtime and maintenance time.
• Bill of material
Ans: –
MES: –
• Emerson
• PLEX
• AVEVA
• IQMS
ERP: –
• SAP
• ORACLE
• SAGE
• Microsoft Dynamics
Ans: –
IEC 61508
IEC 61511
These are the standards followed in plant functional safety. I am thinking about writing a post related to plant
functional safety so stay tuned.
EndNote: –
So, this is my interview question series and I will try to add more and more questions whenever I get back, I will
categorize interview questions topic-wise so you can easily find and prepare.
And if you want to share your interview experience and question then please comment below.