FAQ SV03-032-07-001

Machine Model: CH250


Title: SETTING MAGAZINE HOME POSITION
Objective: MAGAZINE ZRN
Publication: Y/M/D 2002/11/20 Written by Mori Seiki USA

Procedure for Setting Magazine Home Position on Super Hicell


Machine
FAQ SV03-032-07-001 2/13

1) ITEMS THAT CAN CAUSE THE MAGAZINE TO GET OUT OF ADJUSTMENT 3

2) STEP BY STEP INSTRUCTIONS ON RE-TEACHING THE MAGAZINE 3

D. SELECT # 1 B-AMP PARAMETER 5


E. PAGE DOWN TO 2ND PAGE AND SCROLL TO PARAMETER #0011 M.0 5
F. ENGAGE EMERGENCY STOP 6
CHANGE PARAMETER 0011 M.0 TO A 0 6
H. PAGE DOWN 2 MORE PAGES AND THEN SCROLL TO 0041 M SETTING 600 7
I. CHANGE M=600 TO A VALUE OF 5 OR LESS 7
J. TURN MACHINE POWER OFF 8
K. RELEASE EMERGENCY STOP AND TURN MACHINE BACK ON 8
L. AFTER POWER IS RESTORED, PRESS THE DOOR / SHUTTER OPEN AND CLOSED KEY WHILE
PRESSING THE STANDBY KEY. 9
M. PRESS THE MDI KEY 10
N. NOW THE MAGAZINE WILL MOVE USING THE X AXIS + AND -KEYS. 10
O. USE ALIGNMENT TOOL TO LOCATE MAGAZINE TO PROPER POSITION 11
FAQ SV03-032-07-001 3/13

1) Items that can cause the Magazine to get out of Adjustment

A. Broken Belt

B. Malfunction of Motor

C. Parameter Loss

D. Human Interaction

2) Step by Step Instructions on Re-Teaching the Magazine

Open the ATC Shutter using M Code 920. Then from Any Screen on
the Machine, Press the OPER / MAINTE Soft Key.
FAQ SV03-032-07-001 4/13

From this Screen select System F4 Soft, Key. This will take you to
the Maintenance Screen.

From the Maintenance Screen Select Option #16 Peripherals


Controls
FAQ SV03-032-07-001 5/13

Select # 1 B-AMP PARAMETER

Page Down to 2nd Page and Scroll to Parameter #0011 M.0


FAQ SV03-032-07-001 6/13

ENGAGE EMERGENCY STOP

Change Parameter 0011 M.0 to a 0


FAQ SV03-032-07-001 7/13

Page Down 2 more pages and then Scroll to 0041 M setting 600

Change M=600 to a Value of 5 or Less


FAQ SV03-032-07-001 8/13

Turn Machine Power Off

Release Emergency Stop and Turn Machine Back On


FAQ SV03-032-07-001 9/13

After Power is Restored, Press the DOOR / SHUTTER OPEN AND


CLOSED Key while Pressing the STANDBY Key.
FAQ SV03-032-07-001 10/13

Press the MDI Key

Now the Magazine will move using the X-Axis + and -Keys.

X+

X-
FAQ SV03-032-07-001 11/13

Use Alignment Tool to Locate Magazine To Proper Position


FAQ SV03-032-07-001 12/13
FAQ SV03-032-07-001 13/13

Once the Alignment Tool Slips Easily through the Hole, the Magazine is back at its origin.

Turn the Power Off

Engage the EMERGENCT STOP BUTTON

Turn Power On

Set Parameters back to Original State. 0011.0 = 1 / 0041=600

Turn Power Off

Release EMERGENCY STOP BUTTON

Turn Power on.

Close ATC Shutter Door Using M Code 921.