You are on page 1of 2

Concrete conformity assesment

Assesment Date
From Until
Assesment Period

28 Days Compressive Strength N/mm²


Range of
cube results
No. Test Report Reference No Date 1st 2nd 3rd Average
1 JTT/G40PM/002/004/006 9-Jan-21 48.67 53.11 48.44 50.07 4.67
2 JTT/G40PM/012/014/016 9-Jan-21 50.67 54.67 54.22 53.19 4.00
3 JTT/G40PM/022/024/026 9-Jan-21 51.78 55.56 51.56 52.97 4.00

Prepared By: Checked By:


ormity assesment

RMC Plant Location RMC Plant identification

Type of production Initial


Type of concrete mix Pump mix
Compressive Strength Class C32/40
Characteristic Cube Strength fck 40

Conformity Assesment Clause 8.2.1.3


% of range MS EN 206: 2016
Acceptance of test Test Result fci
over average
results (Range < 15%) N/mm²
results
Method A; Eqn 2 fcm Individual: Eqn 1
≥ (fck + 4) fci ≥ (fck - 4)
9.33 Pass 50.07 Pass
7.52 Pass 53.19 Pass Pass
7.55 Pass 52.97 Pass
Mean , fcm 52.08
Std deviation,σ 1.74

Approved By: