Professional Documents
Culture Documents
Uncompromised
UHPLC performance
2
Experience uncompromised UHPLC performance
When you need the best analytical tools for the toughest analytical
challenges, like producing life-saving medicines or ensuring the quality and
safety of our food and environment, the Thermo Scientific™ Vanquish™ Horizon
UHPLC system lets you push the boundaries of separation science.
Designed with innovative technology and attention to fine detail, the Vanquish Horizon UHPLC
system brings exceptional analytical precision, detector sensitivity, and operational simplicity to
enable unmatched robustness and performance. Designed for research labs who need the highest
performing UHPLC and LC-MS, the Vanquish Horizon UHPLC system delivers:
• Highest throughput capabilities for UHPLC and LC-MS with extra-long unattended operation
• Simple integration with your Thermo Scientific™ Chromeleon™ Chromatography Data System (CDS),
Waters™ Empower™ 3 CDS and Agilent™ OpenLab™ CDS software
3
Uncompromised performance
In your laboratory, UHPLC is an essential tool to advance • Minimized system dispersion by employing low dispersion
your research and prevail against the toughest analytical Thermo Scientific™ Viper™ Fingertight Fitting systems
challenges. The Vanquish Horizon UHPLC system is built
• Multiple thermostatting options to refine and take full
with innovative technologies to improve your UHPLC
advantage of your sub 2 µm particle column separations
analysis with:
• Outstanding peak area and retention time precision
• Highest pressure capabilities allowing use of extra-long
sub 2 µm particle columns
Standard Method
30 min gradient
0.4 mL/min-1
600 bar
20 min gradient
0.4 mL/min-1
600 bar
13 min gradient
0.6 mL/min-1
850 bar
8 min gradient
1.0 mL/min-1
1150 bar
5 min gradient
1.1 mL/min-1
1300 bar
5 10 15 20 25
Time (min)
Accelerated peptide mapping utilizing the full power range of the Vanquish Horizon UHPLC system while
maintaining 100% sequence coverage using a Thermo Scientific™ Acclaim™ RSLC 120, C18, 2.2 μm column.
4
Enable your operators
In today’s analytical laboratory environment, your • Viper Fingertight Fittings for nearly zero dead-volume
scientific personnel have limited time for in-depth fluidic connections
familiarization with new instrumentation. An LC system
• Automatic and remote instrument purging
should seamlessly fit into your existing workflows and
processes without requiring extra training or expertise. • Thermo Scientific™ Vanquish™ Solvent Monitor to ensure
enough eluent and waste capacity for every sequence
The Vanquish Horizon UHPLC system brings ease of use
to a new level, enabling every user to deliver exceptional • Easy to use Thermo Scientific Chomeleon CDS method
results, independent of user experience. setup wizards and Smart Startup, Standby and
Shutdown for safe operation
5
High-throughput capabilities
Keep up with the ever-increasing sample processing Vanquish Horizon High-throughput LC systems
demand by improving productivity and throughput. Vanquish Duo UHPLC systems
The Vanquish Horizon UHPLC system can cope with Double your throughput, deepen your sample knowledge,
ultra-high throughput analysis with: and better utilize your bench space with the Thermo
• Extra-low overall system gradient delay volume Scientific™ Vanquish™ Duo UHPLC systems. Two
completely independent flow paths in one system for
• Highest pumping precision for even the most maximum productivity.
challenging gradients
Vanquish Tandem LC systems
• Incredibly short injection cycle which can be nearly
Increase your lab throughput by 30%with the Vanquish
eliminated by additional smart Chromeleon CDS
Tandem LC systems. Maximize the utilization of your
control features
optical detector or mass spectrometer.
• Maximize sample throughput with Thermo Scientific™
Vanquish™ Horizon High-throughput LC systems
Flow Path 1 Analytical Gradient Recondi- Analytical Gradient Recondi- Application Analytical Gradient Recondi- Analytical Gradient Recondi-
Application 1 tioning Application 1 tioning Switch Time Application 2 tioning Application 2 tioning
Flow Path 1 Analytical Gradient Analytical Gradient Application Analytical Gradient Analytical Gradient
Application 1 Application 1 Switch Time Application 2 Application 2 Time savings
Flow Path 2 Recondi- Recondi- Recondi- Recondi- Compared to single channel LC
tioning tioning tioning tioning
Time
6
Improve
Unique application
your quantification
capabilities or Improve your quantification
7
Increased confidence
The analysis of complex samples with difficult-to-resolve Four different Vanquish 2D-LC systems can be
analytes or interfering matrixes could be challenging with configured from Vanquish Horizon modules/components
conventional UHPLC utilizing a single column chemistry. targeting different two-dimensional LC workflows:
In these cases, the analysis may be improved by
employing two-dimensional liquid chromatography to
resolve co-eluting peaks and gain confidence in
your separation.
Simple Online
Switch SPE
2D-LC
Vanquish
Online 2D-LC
Systems
Trap Loop
Heart-Cut Heart-Cut
2D-LC 2D-LC
Thermo Scientific™ Vanquish™ Thermo Scientific™ Vanquish™
Trap Heart-Cut 2D-LC HPLC Loop Heart-Cut 2D-LC HPLC
and UHPLC system and UHPLC system
Transfer one or multiple fractions of Collect one or multiple fractions
the first dimension analytical column of the first dimension separation
to a trap column before submitting to in a sample loop and transfer
the second dimension for improved the cut-out fraction(s) to a
detection flexibility such as, making complementary column chemistry
non-MS compatible separation MS for a second dimension
compatible. separation for peak purity
confirmation.
8
Precision on new levels
Analytical precision, for both retention times and peak • SmartInject technology for increased retention time
areas, are critical to obtain reliable qualitative and precision and prolonged column lifetime
quantitative analytical results for every application and
• SmartFlow™ pumping algorithm for improved flow
specifically in 2D-LC applications. The Vanquish Horizon
accuracy for superior system-to-system reproducibility
UHPLC system brings this precision to new levels of
confidence in your results. • SmartStroke™ technology for a variable stroke volume
resulting in improved signal-to-noise performance for
applications utilizing trifluoroacetic acid
15
R2 = 0.999
10
0
0 0.5 1 1.5
Injection volume [µL]
Autosampler linearity for even low injection volumes, here from
100 nL to 1 µL.
9
Use your existing software infrastructure
for implementation
Regardless of your current software infrastructure, you Chromeleon CDS
can take advantage of the latest innovation of the Scalable from workstation to global enterprise,
Vanquish Horizon UHPLC system. The Vanquish Horizon Chromleon CDS provides complete instrument
system combines perfectly with Chromeleon CDS to take control, data acquisition, data processing and
advantage of the unrivaled flexibility, precision and data security regardless of whether you work
ease-of-use. with the most recent feature release, the
extended support or the long-term support
software version.
Stand-Alone
Workstation
Remote Laboratory
Client Workstation
Chromeleon
Domain Controller
Laboratory
Remote Workstation
Administration
Firewall Database
Server Instrument
Controller
File Server
(NAS, SAN)
10
Benefit from highly-sensitive and selective
mass spectrometry
Mass spectrometry is a prevalent tool in many • Best in class retention time precision for optimal
laboratories. The Vanquish Horizon UHPLC system can selected reaction monitoring
be seamlessly coupled to best in class Thermo Scientific
• Superior separation for minimal ion suppression
triple quadrupole or Thermo Scientific high-resolution
accurate mass Orbitrap mass spectrometers. For single • Minimum carry-over for reliable trace level LC-MS
point control, your LC-MS system can be controlled quantification
completely by Chromeleon CDS.
The Vanquish Horizon UHPLC system with the Thermo Scientific™ Orbitrap Exploris™ 480 mass spectrometer.
11
Detect your analyte
5000
4000
as a smooth and robust LC-MS integration. Based on Concentration vs. peak height plot of nevirapine with data
diode array detection technology, the Multiple Wavelength points that were considered for calibration (black) and data
points that were eliminated from calibration due to curve
Detector offers a cost-effective solution for simultaneously decline (red). Linear calibration with permitted offset and
acquiring up to eight UV-Vis wavelength channels. no weighting.
1.0e6
Counts
5.0e5
G1 B1
0.0e0
12
Charged Aerosol Detection
Void + C
analytical R&D, while its simplicity and reproducibility Unlike mass spectrometry and UV, the CAD is able to measure
all analytes in the sample. Mass spectrometry (MS) requires
benefit manufacturing QA/QC applications.
the analyte to form gas phase ions while response by a UV
detector depends upon the nature of the chromophore.
13
Explore the system
4 7 8
12
14
11
13
10
14
1 Vanquish Solvent Monitor 7 SmartInject Technology
Use the Vanquish Solvent Monitor to increase your Superior retention time precision and accuracy, as
regulatory compliance, productivity, and safety of well as enhanced column protection.
your laboratory. That device guarantees that your
HPLC systems will never run dry and the waste will 8 Easier operation
not spill over, reducing loss of valuable measurement Utilizes tool-free Viper Fingertight
time and sample material. Fittings with near-zero dead volume
operation and ergonomic design.
2 Vanquish User Interface
With the Vanquish User Interface, you are the master 9 Simple maintenance
of your LC instrument. The display always shows you Modules can be repaired without de-stacking; each
the key parameters of your instrument such as flow unit has handles for ease of maneuvers; light bars on
and pressure and guides you in a visual step-by-step the front of the system indicate system status; and
video tutorial through key maintenance tasks. the entire system supports tool-free maintenance.
15
Thermo Scientific LC portfolio overview
Analytical HPLC and UHPLC Nano-, cap-, micro-flow
UHPLC
Application-specific HPLC and UHPLC
Thermo Scientific™ Vanquish™ High-throughput LC Systems
Thermo Scientific™ Vanquish™ Inverse Gradient LC Systems
Thermo Scientific™ Vanquish™ Method Development LC Systems
Thermo Scientific™ Vanquish™ Online 2D-LC Systems
Thermo Scientific™ Vanquish™ Analytical Purification LC System
Thermo Scientific™ Transcend™ UHPLC Systems
• High-pressure binary, • High pressure binary and • High-pressure binary solvent • All-in-one nano-, capillary-,
low-pressure quaternary low-pressure quaternary blending and micro-flow LC systems
solvent blending or isocratic solvent blending • Biocompatible • Accelerating productivity with
flow delivery • Biocompatible long-term, trouble-free
• Industry-leading specifications
• Workhorse instrument • Unparalleled flexibility operation
• Unmatched detection
• Seamless method transfer and control sensitivity • Intelligent at-system or remote
• System intelligence for control, method setup,
improved productivity diagnostics, and troubleshooting