You are on page 1of 6

Requirement Information

MoSCo
ID Requirement Requested By Priority
W
Create 2 new HU Types as
below:
C0 - Half Crate
RE-**-01 Must Have C4 - Half Jumbo gouthamvp@royalenfield.com
Medium

These HU's can be putaway to


shelving bin type B002

Update HU Label printing


TCODE ZEWM080 to have:
Radio buttons for C0 and C4.
RE- The labels printed should have
gouthamvp@royal
80000123 Must Have code HC for C0 and HJ for C4 Medium
enfield.com
65-02 Hus.
Number Ranges:
C0 - 09
C4 - 10

Configure 2 storage sections in


storgae type T024 - Mezzanine
RE-
Shelving.
80000123 Must Have gouthamvp@royalenfield.com
Medium
65-03
C001 - Cold Store Open
C002 - Cold Store Locked

Configure 2 new storage section


indicators C001 and C002 and
RE- introduce restriction so that
gouthamvp@royal
80000123 Must Have these may be put away only in Medium
enfield.com
65-04 sections C001 and C002
respectively in storage type
T024.
Assign picking from C001 and
C002 sections to activity area
ZN02. These picks should be
assigned to a separate queue.
It has been noted that T024 is
RE-
not assigned to any Pick AA in gouthamvp@royal
80000123 Must Have Medium
config. Upload of sort sequence enfield.com
65-05
will be performed
All picks from cold store will
be assigned to COLD-PACK.
This can be changed based on
picking type if required.
Relationship Traceability
Business Objective Deliverables

2 new types of HU has been introduced in the RE 1. Unit Test Script -


warehouse. These can be kept in B002 type bins Executed

ZEWM080 is used for printing of HU labels. HU


labels contain the HU type initials. With the 1. TS
introduction of C0 and C4, ZEWM080 needs 2. Unit Test Script -
modification to allow printing for these new HU Executed
types.

New multi level shelving for cold store has been


erected in the RE warehouse at Oragadam. There 1. Unit Test Script -
are 2 sections in there, open and close. The same Executed
needs to reflect in the system.

Certain identified products can only be putaway


to the new stroage sections. Additionally these 1. Unit Test Script -
identified products may not be putaway to the Executed
other sections in the shelving.
The new cold store is at a considerable distance
from the existing shelving. Thus these will be 1. Unit Test Script -
required to have separate warehouse orders and Executed
separate queues.
ationship Traceability
Acceptance Criteria Validation

1. HUs can be created in the system using the 2 new HU


types.
2. Number range for these Hus should be different than that Unit Test
of the existing HU types UAT
3. These HU types can be putaway to only B002 bin type in
the shelving

1. Radio buttons as below should be available in the report


screen of ZEWM080
- Half Crate(C0) Unit Test
-Half Jumbo(C4) UAT
2. On printing of labels using the above the label should be
printed with initials 'HC' for C0 and 'HJ' for C4

1. Bins could be created with storage section C001 and Unit Test
C002 and bin type B002 UAT

1. Products with indicator C001 and C002 can be putaway


to only C001 and C002 storage sections respectively within
T024.
Unit Test
2. Products with other storage section indicators may not be
UAT
putaway to C001 and C002 storage sections in T024
3. Products with storage section indicators C001 and C002
may not be putaway to racking storages
1. Picking from the cold store sections C001 and C002 of
T024 should be assigned to a separate warehouse order and
to a separate queue. Unit Test
2. Putaway to C001 and C002 cold store sections of T024 UAT
should be assigned to a separate warehouse order and to a
separate queue.